Evaluating Effects of Building Envelope Thermal Loads on Energy use and Thermal Comfort for a Bedroom TAC System

Abstract There has been an increasing concern on thermal comfort in sleeping environments and its associated energy use in the past few years. To improve the thermal environment and reduce energy use of air conditioning in bedrooms, task/ambient air conditioning (TAC) can be applied and was studied previously. Due to the variation of the envelope thermal loads in a bedroom during night, it is necessary to study the thermal environment inside the bedroom and the energy use of a TAC system for the bedroom at varying envelope thermal loads. Therefore, this paper reports on a numerical study on a TAC system applied to a bedroom with different envelope heat gains. PMV and EUC (energy utilization coefficient) values were evaluated, respectively. The study results indicated that when envelope thermal loads was higher, the advantage of the TAC system in energy saving was greater for the same thermal comfort level. However, it should be noted that a higher envelope thermal load could also resulted in the non-uniformity in air flow and air temperature distributions, leading to a possible uncomfortable micro environment.

[1]  Dongmei Pan,et al.  Performance evaluation of a novel bed-based task/ambient conditioning (TAC) system , 2012 .

[2]  Ye Yao,et al.  Optimization on indoor air diffusion of floor-standing type room air-conditioners , 2008 .

[3]  F. Menter Two-equation eddy-viscosity turbulence models for engineering applications , 1994 .

[4]  Dongmei Pan,et al.  Parameter optimization for operation of a bed-based task/ambient air conditioning (TAC) system to achieve a thermally neutral environment with minimum energy use , 2017 .

[5]  Wontae Kim,et al.  Thermal characteristics of a personal environment module task air conditioning system: an experimental study , 2001 .

[6]  Dongmei Pan,et al.  Performance evaluation of an air conditioning system with different heights of supply outlet applied to a sleeping environment , 2014 .

[7]  Dongmei Pan,et al.  Experimental and numerical study on air flow and moisture transport in sleeping environments with a task/ambient air conditioning (TAC) system , 2016 .

[8]  Zhao Zhang,et al.  Evaluation of Various Turbulence Models in Predicting Airflow and 1 Turbulence in Enclosed Environments by CFD : Part-1 : 2 Summary of Prevalent Turbulence Models 3 4 , 2007 .

[9]  Shiming Deng,et al.  An experimental study on even frosting performance of an air source heat pump unit with a multi-circuit outdoor coil , 2016 .

[10]  Muhsin Kilic,et al.  Numerical analysis of air flow, heat transfer, moisture transport and thermal comfort in a room heat , 2011 .

[11]  Jianlei Niu,et al.  CFD Study of the Thermal Environment around a Human Body: A Review , 2005 .

[12]  Luisa F. Cabeza,et al.  Economic impact of integrating PCM as passive system in buildings using Fanger comfort model , 2016 .

[13]  D. Shiming,et al.  Computational fluid dynamics (CFD) modelling of air flow field, mean age of air and CO2 distributions inside a bedroom with different heights of conditioned air supply outlet , 2016 .

[14]  Shiming Deng,et al.  An experimental study on defrosting performance for an air source heat pump unit with a horizontally installed multi-circuit outdoor coil , 2016 .

[15]  Lina Yang,et al.  Cooling load reduction by using thermal mass and night ventilation , 2008 .

[16]  Shinichi Tanabe,et al.  Thermal sensation and comfort with different task conditioning systems , 2007 .

[17]  Shiming Deng,et al.  A study on the thermal comfort in sleeping environments in the subtropics : Developing a thermal comfort model for sleeping environments , 2008 .

[18]  Shiming Deng,et al.  A study on the characteristics of nighttime bedroom cooling load in tropics and subtropics , 2004 .

[19]  Mengjie Song,et al.  An experimental study on defrosting performance of an air source heat pump unit with a multi-circuit outdoor coil at different frosting evenness values , 2016 .

[20]  Dongmei Pan,et al.  Thermal, ventilation and energy saving performance evaluations of a ductless bed-based task/ambient air conditioning (TAC) system , 2013 .

[21]  Shiming Deng,et al.  Application of TOPSIS method in evaluating the effects of supply vane angle of a task/ambient air conditioning system on energy utilization and thermal comfort , 2016 .

[22]  G. D. Raithby,et al.  A Finite-Volume Method for Predicting a Radiant Heat Transfer in Enclosures With Participating Media , 1990 .

[23]  Anastasios I. Stamou,et al.  Verification of a CFD model for indoor airflow and heat transfer , 2006 .