Impedance pneumography for long-term monitoring of respiration during sleep in adult males.

Impedance pneumography is based on the relationship between respired volume (delta V) and changes of transthoracic impedance (delta/Z/) during breathing. The impedance signal, the relationship between delta V and delta/Z/ and the success rate during long-term recording was studied in 11 healthy adult males, aged 21-46, by a portable tape recorder (Oxford Medilog 4-24). The signals from the tape recorder (delta/Z/), and from a spirometer (delta V) were recorded simultaneously on a mingograph during normal breathing, apnoea, deep sighs, and coughs. The relationship between delta V and delta/Z/ was also analysed on an X-Y recorder. Delta/Z/ was delayed in relation to delta V and during one respiratory cycle the relationship was not linear. The time constant of delta/Z/ was 6 s. A significant correlation was found between peak values of delta V and delta/Z/ for 0 less than delta V less than 2.5 litres. Long-term recording of delta/Z/ during one night's sleep resulted in a success rate of 63-100%, mean 90%. Invalidation of the impedance signal was caused by overloading (81%) and interference (19%). It is concluded that the Medilog respiratory recorder enables determination of respiratory frequency, periods of apnoea and a semiquantitative estimate of volume, but artifacts may invalidate the signal.

[1]  A F Pacela,et al.  Impedance pneumography—A survey of instrumentation techniques , 1966, Medical & biological engineering.

[2]  J H Auchincloss,et al.  Impedance pneumograph and magnetometer methods for monitoring tidal volume. , 1974, Journal of applied physiology.

[3]  L H Hamilton,et al.  Measurement of ventilation using digitally filtered transthoracic impedance. , 1983, Journal of applied physiology: respiratory, environmental and exercise physiology.

[4]  L. E. Baker,et al.  THE MEASUREMENT OF RESPIRATORY VOLUMES IN ANIMALS AND MAN WITH USE OF ELECTRICAL IMPEDANCE , 1970 .

[5]  D. Southall,et al.  An explanation for failure of impedance apnoea alarm systems. , 1980, Archives of disease in childhood.

[6]  T Olsson,et al.  Transthoracic impedance, with special reference to newborn infants and the ratio air-to-fluid in the lungs. , 1970, Acta paediatrica Scandinavica. Supplement.

[7]  P. Bjerregaard The quality of ambulatory ECG-recordings and accuracy of semi-automatic arrhythmia analysis. An evaluation of the Medilog-Pathfinder system. , 1980, European heart journal.

[8]  W. L. Cooley,et al.  Impedance pneumography. Comparison between chest impedance changes and respiratory volumines in 11 healthy volunteers. , 1972, Chest.

[9]  R. C. Kory,et al.  Impedance measurement of tidal volume and ventilation. , 1965, Journal of applied physiology.

[10]  C. Hanning Monitoring respiration in the postoperative period. , 1982, British journal of anaesthesia.

[11]  D. Shannon,et al.  The pediatric pneumogram: a new method for detecting and quantitating apnea in infants. , 1975, Pediatrics.