Advantages Of List-Mode Acquisition Of Dynamic Cardiac Data

Conventional frame-mode acquisition of multigated blood-pool (MUGA) studies is an imprecise means to study cardiac dynamics in part because the energy and ECG waveform information is not retained Early methods for list-mode acquisition were also somewhat limited in that only the (x,y) coordinate, a timing pulse and an R-wave detect pulse were stored. We have extended list-mode capability to include full storage of the ECG waveform and the energy value associated with each spatial coordinate. The spatial coordinates (x and y), energy value (E), and an encoded physiologicitiming signal (pit) are stored on an event-by-event basis as %bit values. These four bytes are streamed onto a hard disk storage device allowing even stress gated blood pool studies to be recorded. List-mode acquisition gives greater flexibility than framemode. Among the demonstrable advantages this flexibility provides are the ability to: 1) Measure and correct respirational displacement of the ventricle to minimize motion blurring; 2) Form gated sequences representing only a specific aberrancy for detection of ectopic ventricular foci; and 3) Use the stored multispectral energy information to perform scatter correction on the dynamic images. To conclusively demonstrate the improved resolution of the list-mode methodology, a dynamic phantom was used to sinnulate blurring due to respiration. The advantages of list-mode warrant its further use, and it may be especially valuable for wall thickness measurements.

[1]  B. W. Reutter,et al.  Cardiac creep during rest/stress myocardial perfusion studies - patient motion and lung air redistribution , 1996 .

[2]  A L Muir,et al.  The influence of ectopic heart beats in gated ventricular blood-pool studies. , 1980, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[3]  R L Eisner Sensitivity of SPECT thallium-201 myocardial perfusion imaging to patient motion. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  Y Yonekura,et al.  Motion correction in exercise first-pass radionuclide ventriculography without an external point source. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  D. Berman,et al.  Detection and correction of patient motion in dynamic and static myocardial SPECT using a multi-detector camera. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  Michael V. Green,et al.  Left-ventricular peak ejection rate, filling rate, and ejection fraction--frame rate requirements at rest and exercise: concise communication. , 1979, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[7]  B E Oppenheim,et al.  A method using a digital computer for reducing respiratory artifact on liver scans made with a camera. , 1971, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  S L Bacharach,et al.  Artifactual inhomogeneities in myocardial PET and SPECT scans in normal subjects. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  M E Phelps,et al.  Electrocardiographic gating in positron emission computed tomography. , 1979, Journal of computer assisted tomography.

[10]  R H Jones,et al.  Comparison of bicycle and treadmill radionuclide angiocardiography. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  M W Groch,et al.  Dual-isotope motion correction technique for gated exercise scintigraphy. , 1985, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[12]  T K Johnson,et al.  A new method for the correction of gamma camera nonuniformity due to spatial distortion. , 1996, Physics in medicine and biology.

[13]  J. Cooper,et al.  Effect of patient motion on tomographic myocardial perfusion imaging. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[14]  D S Berman,et al.  "Upward creep" of the heart: a frequent source of false-positive reversible defects during thallium-201 stress-redistribution SPECT. , 1989, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[15]  Parker Ja Effect of Motion on Cardiac SPECT Imaging , 1993 .

[16]  J E Juni,et al.  Effects of gating modes on the analysis of left ventricular function in the presence of heart rate variation. , 1988, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[17]  M. A. Douglas,et al.  A real-time system for multi-image gated cardiac studies. , 1977, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[18]  M V Green,et al.  Comparison of fixed and variable temporal resolution methods for creating gated cardiac blood-pool image sequences. , 1990, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  P Schmidlin,et al.  Development and comparison of computer methods for organ motion correction in scintigraphy. , 1975, Physics in medicine and biology.

[20]  E G DePuey,et al.  Optimal specificity of thallium-201 SPECT through recognition of imaging artifacts. , 1989, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[21]  B E Sobel,et al.  Influence of Cardiac and Respiratory Motion on Tomographic Reconstructions of the Heart: Implications for Quantitative Nuclear Cardiology , 1982, Journal of computer assisted tomography.

[22]  M A Wilson,et al.  Correction of Respiratory Motion in Hepatic Scintigraphy , 1981, Clinical nuclear medicine.

[23]  P B Hoffer,et al.  A simple device for reducing motion artifacts in gamma camera images. , 1972, Radiology.

[24]  G S Johnston,et al.  Real-time radionuclide cineangiography in the noninvasive evaluation of global and regional left ventricular function at rest and during exercise in patients with coronary-artery disease. , 1977, The New England journal of medicine.