A multidisciplinary approach to the study of cultural heritage environments: Experience at the Palatina Library in Parma.

The aim of this paper is to describe a multidisciplinary approach including biological and particle monitoring, and microclimate analysis associated with the application of the Computational Fluid Dynamic (CFD). This approach was applied at the Palatina historical library in Parma. Monitoring was performed both in July and in December, in the absence of visitors and operators. Air microbial monitoring was performed with active and passive methods. Airborne particles with a diameter of ≥0.3, ≥0.5, ≥1 and ≥5 μm/m3, were counted by a laser particle counter. The surface contamination of shelves and manuscripts was assessed with nitrocellulose membranes. A spore trap sampler was used to identify both viable and non-viable fungal spores by optical microscope. Microbiological contaminants were analyzed through cultural and molecular biology techniques. Microclimatic parameters were also recorded. An infrared thermal camera provided information on the surface temperature of the different building materials, objects and components. Transient simulation models, for coupled heat and mass-moisture transfer, taking into account archivist and general public movements, combined with the related sensible and latent heat released into the environment, were carried out applying the CFD-FE (Finite Elements) method. Simulations of particle tracing were carried out. A wide variability in environmental microbial contamination, both for air and surfaces, was observed. Cladosporium spp., Alternaria spp., Aspergillus spp., and Penicillium spp. were the most frequently found microfungi. Bacteria such as Streptomyces spp., Bacillus spp., Sphingomonas spp., and Pseudoclavibacter as well as unculturable colonies were characterized by molecular investigation. CFD simulation results obtained were consistent with the experimental data on microclimatic conditions. The tracing and distribution of particles showed the different slice planes of diffusion mostly influenced by the convective airflow. This interdisciplinary research represents a contribution towards the definition of standardized methods for assessing the biological and microclimatic quality of indoor cultural heritage environments.

[1]  Cesira Pasquarella,et al.  [Air microbial sampling: the state of the art]. , 2008, Igiene e sanita pubblica.

[2]  C Pasquarella,et al.  New methods for microbial contamination monitoring: an experiment on board the MIR orbital station. , 1997, Acta astronautica.

[3]  Carla Balocco,et al.  Assessing the effects of sliding doors on an operating theatre climate , 2012 .

[4]  R. Albertini,et al.  Proposal for an integrated approach to microbial environmental monitoring in cultural heritage: experience at the Correggio exhibition in Parma , 2011 .

[5]  C. Pasquarella,et al.  Italian multicenter study on infection hazards during dental practice: Control of environmental microbial contamination in public dental surgeries , 2008, BMC public health.

[6]  Paolo Castiglia,et al.  Italian multicentre study on microbial environmental contamination in dental clinics: a pilot study. , 2010, The Science of the total environment.

[7]  P. Vitali,et al.  Microbial air monitoring in operating theatres: experience at the University Hospital of Parma. , 2012, The Journal of hospital infection.

[8]  C Pasquarella,et al.  Comparative efficiency of nitrocellulose membranes versus RODAC plates in microbial sampling on surfaces. , 1999, The Journal of hospital infection.

[9]  J. Lumley,et al.  A First Course in Turbulence , 1972 .

[10]  Refrigerating,et al.  Ventilation for acceptable indoor air quality : ANSI/ASHRAE Standard 62.1-2013 , 2013 .

[11]  F. Palla,et al.  Microscopy and Molecular biology techniques for the study biocenosis diversity in semi-confined environments , 2010 .

[12]  B. Launder,et al.  The numerical computation of turbulent flows , 1990 .

[13]  F. Palla Characterization of microbial communities in pest colonized books by molecular biology tools , 2011 .

[14]  C. Sabbioni,et al.  Cultural heritage and aerobiology. Methods and measurement techniques for biodeterioration monitoring , 2003 .

[15]  H. Braband,et al.  General principles and methods , 1968 .

[16]  Cesira Pasquarella,et al.  Proposal for a biological environmental monitoring approach to be used in libraries and archives. , 2012, Annals of agricultural and environmental medicine : AAEM.

[17]  J. H. Harker,et al.  Particle technology and separation processes , 1991 .

[18]  C. Pasquarella,et al.  Microbial environmental contamination in Italian dental clinics: A multicenter study yielding recommendations for standardized sampling methods and threshold values. , 2012, The Science of the total environment.

[19]  F. Palla,et al.  Multiple approaches to identify bacteria in archaeological waterlogged wood , 2013 .

[20]  Carla Balocco,et al.  Numerical multi-physical approach for the assessment of coupled heat and moisture transfer combined with people movements in historical buildings , 2014 .

[21]  Dominique Pelletier,et al.  A universal formulation of two-equation models for adaptive computation of turbulent flows , 2000 .

[22]  C. Sabbioni,et al.  Cultural Heritage and Aerobiology , 2003 .

[23]  C Pasquarella,et al.  The index of microbial air contamination. , 2000, The Journal of hospital infection.