Electrochemolipolysis of Human Adipose Tissue.

Importance: Body fat contouring procedures have increasingly grown in popularity over the years. As such, there is a need for inexpensive, minimally invasive, and simple fat reduction/contouring technique. Objective: To examine the acid-base and histological changes in ex vivo human adipose tissue after electrochemolipolysis (ECL). Design, Setting, and Participants: Panniculus tissue specimens obtained after abdominoplasty procedures were tumesced with normal saline. Two platinum needle electrodes were inserted into each sample and connected to a DC power supply. Voltage (3-6 V) was varied and applied for 5 min. Specimens were sectioned through a sagittal midline across both electrode insertion sites and immediately stained with pH-sensitive dye. A numerical algorithm was used to calculate the area of the dye color change for each dosimetry pair. Samples were also evaluated utilizing light microscopy (hematoxylin and eosin). An ex vivo human adipose tissue model was used for evaluating the effects of ECL. Results: Acidic and basic pH was appreciated surrounding the anode and cathode insertion sites, respectively. The effect was spatially localized and dose dependent. Statistical analysis of these data showed no significant difference between the mean area of the pH disturbance generated at the anode compared with the cathode at 3 V for 5 min (6.04 mm2 vs. 2.95 mm2, p = 0.40, 95% CI -4.8 to 11). A significantly greater area of pH disruption was generated at the cathode versus the anode in groups 4 V for 5 min (14.7 mm2 vs. 5.00 mm2, p = 0.032, 95% CI 0.93-19), 5 V for 5 min (15.5 mm2 vs. 6.72 mm2, p = 0.019, 95% CI 1.6-16), and 6 V for 5 min (22.5 mm2 vs. 10.0 mm2, p = 0.047, 95% CI 0.22-25). Acute structural changes in adipocytes were observed in all specimens. Vascular damage with adjacent adipocyte necrosis was prominent at the cathode site in group 6 V for 5 min. Conclusions and Relevance: ECL at the studied dosimetry parameters induced acid and base changes in human adipose tissue, suggesting its potential use in nonsurgical fat reduction as an ultralow cost alternative to current lipolytic devices and pharmaceuticals. Level of Evidence: NA.

[1]  T. Krasieva,et al.  Multiphoton Microscopy of Collagen Structure in Ex Vivo Human Skin Following Electrochemical Therapy , 2020, Lasers in surgery and medicine.

[2]  R. Bard,et al.  Ultrasound Assessment of Subcutaneous Abdominal Fat Thickness After Treatments With a High-Intensity Focused Electromagnetic Field Device: A Multicenter Study. , 2019, Dermatologic surgery : official publication for American Society for Dermatologic Surgery [et al.].

[3]  Joseph C. Jing,et al.  Association of Electrochemical Therapy With Optical, Mechanical, and Acoustic Impedance Properties of Porcine Skin , 2017, JAMA facial plastic surgery.

[4]  G. Moullec,et al.  Factors associated with adipocyte size reduction after weight loss interventions for overweight and obesity: a systematic review and meta-regression. , 2017, Metabolism: clinical and experimental.

[5]  E. Deeks Deoxycholic Acid: A Review in Submental Fat Contouring , 2016, American Journal of Clinical Dermatology.

[6]  M. Chung,et al.  Cryolipolysis for Fat Reduction and Body Contouring: Safety and Efficacy of Current Treatment Paradigms , 2015, Plastic and reconstructive surgery.

[7]  Daniel P. Friedmann A Review of the Aesthetic Treatment of Abdominal Subcutaneous Adipose Tissue: Background, Implications, and Therapeutic Options , 2015, Dermatologic surgery : official publication for American Society for Dermatologic Surgery [et al.].

[8]  Cyrus T. Manuel,et al.  In‐depth analysis of pH‐dependent mechanisms of electromechanical reshaping of rabbit nasal septal cartilage , 2014, The Laryngoscope.

[9]  Michael R Hamblin,et al.  Low‐level laser therapy for fat layer reduction: A comprehensive review , 2013, Lasers in surgery and medicine.

[10]  Cyrus T. Manuel,et al.  Ex Vivo Electromechanical Reshaping of Costal Cartilage in the New Zealand White Rabbit Model , 2013, The Laryngoscope.

[11]  Michael Kreindel,et al.  Non-Surgical Body Contouring: Introduction of a New Non-Invasive Device for Long-Term Localized Fat Reduction and Cellulite Improvement Using Controlled, Suction Coupled, Radiofrequency Heating and High Voltage Ultra-Short Electrical Pulses , 2012 .

[12]  B. Wong,et al.  Changes in the tangent modulus of rabbit septal and auricular cartilage following electromechanical reshaping. , 2011, Journal of biomechanical engineering.

[13]  Cyrus T. Manuel,et al.  Electromechanical reshaping of costal cartilage grafts: A new surgical treatment modality , 2011, The Laryngoscope.

[14]  Brian J. F. Wong,et al.  Needle-Electrode-Based Electromechanical Reshaping of Rabbit Septal Cartilage: A Systematic Evaluation , 2011, IEEE Transactions on Biomedical Engineering.

[15]  Brian J. F. Wong,et al.  Needle Electrode-Based Electromechanical Reshaping of Cartilage , 2010, Annals of Biomedical Engineering.

[16]  Ruth M. Franklin,et al.  Longitudinal changes in abdominal fat distribution with menopause. , 2009, Metabolism: clinical and experimental.

[17]  C. Chlebicki,et al.  Thermoforming of tracheal cartilage: Viability, shape change, and mechanical behavior , 2008, Lasers in surgery and medicine.

[18]  Brian J. F. Wong,et al.  Stress Relaxation in Porcine Septal Cartilage During Electromechanical Reshaping: Mechanical and Electrical Responses , 2006, Annals of Biomedical Engineering.

[19]  Wadih Arap,et al.  Reversal of obesity by targeted ablation of adipose tissue , 2004, Nature Medicine.

[20]  Cyrus T. Manuel,et al.  In vivo electromechanical reshaping of ear cartilage in a rabbit model: a minimally invasive approach for otoplasty. , 2013, JAMA facial plastic surgery.

[21]  D. Sarwer,et al.  Body image and cosmetic medical treatments. , 2004, Body image.