Dynamic braking system of a tidal generator

Renewable energy generation has experienced significant cost reductions during the past decades, and it has become more accepted by the global population. In the beginning, wind generation dominated the development and deployment of renewable energy; however, during recent decades, photovoltaic (PV) generation has grown at a very significant pace due to the tremendous decrease in the cost of PV modules. The focus on renewable energy generation has now expanded to include new types with promising future applications, such as river and tidal generation. The input water flow to these types of resources is more predictable than wind or solar generation. The data used in this paper is representative of a typical river or tidal generator. The analysis is based on a generator with a power rating of 40 kW. The tidal generator under consideration is driven by two sets of helical turbines connected to each side of the generator located in between the turbines. The generator is operated in variable speed, and it is controlled to maximize the energy harvested as well as the operation of the turbine generator. The electrical system consists of a three-phase permanent magnet generator connected to a three-phase passive rectifier. The output of the rectifier is connected to a DC-DC converter to match the rectifier output to the DC bus voltage of the DC-AC inverter. The three-phase inverter is connected to the grid, and it is controlled to provide a good interface with the grid. One important aspect of river and tidal generation is the braking mechanism. In a tidal generator, the braking mechanism is important to avoid a runaway condition in case the connection to the grid is lost when there is a fault in the lines. A runaway condition may lead to an overspeed condition and cause extreme stresses on the turbine blade structure and eventual disintegration of the mechanical structure. In this paper, the concept of the dynamic braking system is developed and investigated for normal and abnormal operations. The main objective is to optimize the performance under emergency braking while designing the system to be as simple as possible to avoid overdesigning the power electronics or exceeding the target budget.

[1]  M.E.H. Benbouzid,et al.  Marine Tidal Current Electric Power Generation Technology: State of the Art and Current Status , 2007, 2007 IEEE International Electric Machines & Drives Conference.

[2]  V. Staudt,et al.  Permanent-Magnet Synchronous Machine model for urban transport applications , 2010, 2010 12th International Conference on Optimization of Electrical and Electronic Equipment.

[3]  Kartik B. Ariyur,et al.  Electric machine vs mechanical brakes for traction control with real time extremum seeking control , 2014, IECON 2014 - 40th Annual Conference of the IEEE Industrial Electronics Society.

[4]  Koh Siong Lee,et al.  Preliminary investigation of the potential of harnessing tidal energy for electricity generation in Malaysia , 2008, 2008 IEEE/PES Transmission and Distribution Conference and Exposition.

[5]  Duan Xiaoli,et al.  Portable maximum power tracking method of tidal generation system based on output slope characteristics , 2014, Proceedings of the 33rd Chinese Control Conference.

[6]  Jun Hao,et al.  Portable maximum power tracking method of tidal generation system based on output slope characteristics , 2014, CCC 2014.

[7]  Eduard Muljadi,et al.  Review of Marine Hydrokinetic Power Generation and Power Plant , 2015 .

[8]  Wenyuan Li,et al.  Probabilistic modeling of tidal power generation , 2015, 2015 IEEE Power & Energy Society General Meeting.

[9]  Y. Kyozuka,et al.  Tidal Current Power Generation Making Use of a Bridge Pier , 2006, OCEANS 2006 - Asia Pacific.

[10]  Rag Gyo Jeong,et al.  New control method of maximum power point tracking for tidal energy generation system , 2007, 2007 International Conference on Electrical Machines and Systems (ICEMS).