Image-guided small animal radiation research platform: calibration of treatment beam alignment

Small animal research allows detailed study of biological processes, disease progression and response to therapy with the potential to provide a natural bridge to the clinical environment. The small animal radiation research platform (SARRP) is a portable system for precision irradiation with beam sizes down to approximately 0.5 mm and optimally planned radiation with on-board cone-beam CT (CBCT) guidance. This paper focuses on the geometric calibration of the system for high-precision irradiation. A novel technique for the calibration of the treatment beam is presented, which employs an x-ray camera whose precise positioning need not be known. Using the camera system we acquired a digitally reconstructed 3D 'star shot' for gantry calibration and then developed a technique to align each beam to a common isocenter with the robotic animal positioning stages. The calibration incorporates localization by cone-beam CT guidance. Uncorrected offsets of the beams with respect to the calibration origin ranged from 0.4 mm to 5.2 mm. With corrections, these alignment errors can be reduced to the sub-millimeter range. The calibration technique was used to deliver a stereotactic-like arc treatment to a phantom constructed with EBT Gafchromic films. All beams were shown to intersect at a common isocenter with a measured beam (FWHM) of approximately 1.07 mm using the 0.5 mm collimated beam. The desired positioning accuracy of the SARRP is 0.25 mm and the results indicate an accuracy of 0.2 mm. To fully realize the radiation localization capabilities of the SARRP, precise geometric calibration is required, as with any such system. The x-ray camera-based technique presented here provides a straightforward and semi-automatic method for system calibration.

[1]  Brian G. Starkoski,et al.  Ultrasound backscatter microscope for skin imaging , 1993 .

[2]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[3]  S Mutic,et al.  MicroRT-small animal conformal irradiator. , 2007, Medical physics.

[4]  F. Franconi,et al.  In vivo quantitative microimaging of rat spinal cord at 7T , 2000, Magnetic resonance in medicine.

[5]  David A Jaffray,et al.  The stability of mechanical calibration for a kV cone beam computed tomography system integrated with linear accelerator. , 2005, Medical physics.

[6]  Simon R Cherry,et al.  Complementary emerging techniques: high-resolution PET and MRI , 2001, Current Opinion in Neurobiology.

[7]  M J Murphy,et al.  The accuracy of dose localization for an image-guided frameless radiosurgery system. , 1996, Medical physics.

[8]  L From,et al.  Ultrasound backscatter microscope analysis of mouse melanoma progression. , 1996, Ultrasound in medicine & biology.

[9]  Otto Zhou,et al.  A novel high resolution micro‐radiotherapy system for small animal irradiation for cancer research , 2007, BioFactors.

[10]  D W Holdsworth,et al.  Elastic response of human iliac arteries in-vitro to balloon angioplasty using high-resolution CT. , 1998, Journal of biomechanics.

[11]  Robert Jeraj,et al.  Design of a radiation facility for very small specimens used in radiobiology studies , 2008, Physics in medicine and biology.

[12]  Marc S. Mendonca,et al.  Use of the Leksell Gamma Knife for Localized Small Field Lens Irradiation in Rodents , 2003, Technology in cancer research & treatment.

[13]  Peter I. Corke,et al.  A tutorial on visual servo control , 1996, IEEE Trans. Robotics Autom..

[14]  William E. Higgins,et al.  Multi-generational analysis and visualization of the vascular tree in 3D micro-CT images , 2002, Comput. Biol. Medicine.

[15]  R Weissleder,et al.  In vivo imaging of gene and cell therapies. , 2001, Experimental hematology.

[16]  Jonathan Grudin,et al.  Design and evaluation , 1995 .

[17]  Christopher H Contag,et al.  Design and evaluation of a variable aperture collimator for conformal radiotherapy of small animals using a microCT scanner. , 2007, Medical physics.

[18]  K. Uğurbil,et al.  Microstrip RF surface coil design for extremely high‐field MRI and spectroscopy , 2001, Magnetic resonance in medicine.

[19]  David A. Jaffray,et al.  SU‐GG‐J‐70: Development of An Image‐Guided Conformal Small Animal Irradiation Platform , 2008 .

[20]  J. Régis,et al.  Effect of Gamma Knife Radiosurgery on Rat Brain Sodium Channel Subunit mRNA Expression , 1998, Stereotactic and Functional Neurosurgery.

[21]  Peter Kazanzides,et al.  High-resolution, small animal radiation research platform with x-ray tomographic guidance capabilities. , 2008, International journal of radiation oncology, biology, physics.

[22]  Simon R Cherry,et al.  Evaluation of a stereotactic frame for repositioning of the rat brain in serial positron emission tomography imaging studies , 2001, Journal of Neuroscience Methods.