Fluid-dynamic characterisation of the Mont Blanc tunnel by multi-point airflow measurements

Abstract Long road and railway tunnels necessitate of a fine-tuned control of the ventilation system to be activated, for both safety and air quality maintenance reasons. This, in turn, requires that the main fluid-dynamic parameters of the tunnel are known with sufficient accuracy, so that the system behaviour can be predicted with reasonable confidence under standard and emergency operative conditions. As a first step in the modelling of the complex system embodying the 11,611 m long Mont Blanc road tunnel, and its ventilation facilities, a movable 5-point survey rake was designed and built-up, for detecting the distribution of the axial velocity on the tunnel cross-section. Two extensive experimental campaigns were carried out, where the airflow-rates were either measured at different stations along the tunnel length (C1), or at a fixed location, under purely axial main-flow conditions and varying the number of the activated axial fan pairs (C2). A simplified dynamic model of the tunnel was developed, and the airflow data from the experiments were used for the model fine-tuning, additional CFD analyses having provided extra information on concentrated pressure losses connected with air inlet and discharge through the tunnel ends. The Mont Blanc tunnel was finally characterised in terms of friction factors and jet-fans installation efficiency.

[1]  Alan N. Beard,et al.  The Handbook of Tunnel Fire Safety , 2011 .

[2]  Hrvoje Jasak,et al.  A tensorial approach to computational continuum mechanics using object-oriented techniques , 1998 .

[3]  A Kashef,et al.  Investigation of the Performance of Emergency Ventilation Strategies in the Event of Fires in a Road Tunnel — A Case Study , 2008 .

[4]  Wan Ki Chow,et al.  Numerical studies on performance evaluation of tunnel ventilation safety systems , 2003 .

[5]  Thomas F. Coleman,et al.  An Interior Trust Region Approach for Nonlinear Minimization Subject to Bounds , 1993, SIAM J. Optim..

[6]  Hong-Ming Jang,et al.  A novel approach to the transient ventilation of road tunnels , 2000 .

[7]  F Tarada,et al.  Impulse Ventilation for Tunnels - A State of the Art Review , 2009 .

[8]  Olivier Vauquelin,et al.  Influence of tunnel width on longitudinal smoke control , 2006 .

[9]  R. P. Benedict,et al.  Fundamentals of pipe flow , 1980 .

[10]  Ji-Oh Yoo,et al.  A study on the smoke control characteristic of the longitudinally ventilated tunnel fire using PIV , 2006 .

[11]  P. Roache QUANTIFICATION OF UNCERTAINTY IN COMPUTATIONAL FLUID DYNAMICS , 1997 .

[12]  Y. Wu,et al.  Control of smoke flow in tunnel fires using longitudinal ventilation systems - a study of the critical velocity , 2000 .

[13]  Paul Jowitt,et al.  The influence of longitudinal ventilation systems on fires in tunnels , 2001 .

[14]  T. Shih,et al.  A new k-ϵ eddy viscosity model for high reynolds number turbulent flows , 1995 .

[15]  S. Patankar Numerical Heat Transfer and Fluid Flow , 2018, Lecture Notes in Mechanical Engineering.

[16]  Hong-Ming Jang,et al.  On the determination of the aerodynamic coefficients of highway tunnels , 2002 .

[17]  Tony Lemaire,et al.  Large Scale Fire Tests in the Second Benelux Tunnel , 2006 .

[18]  Yasushi Oka,et al.  Control of smoke flow in tunnel fires , 1995 .