Heartbeat interval extraction using doppler radar for health monitoring

In this paper heartbeat interval extraction methods using Doppler radar are reviewed. While single channel CW radar offers simple architecture and signal processing, this method is very sensitive to subject position and may result in rate doubling, or the coupling between heart and respiratory rates. Quadrature radio architecture is used to overcome this limitation. The use of linear and non-linear demodulation methods was explored for heartbeat interval extraction.

[1]  Neil Genzlinger A. and Q , 2006 .

[2]  M.Y.W. Chia,et al.  Through-wall UWB radar operating within FCC's mask for sensing heart beat and breathing rate , 2005, 2005 European Microwave Conference.

[3]  E. F. Greneker,et al.  A non-contact lie detector using radar vital signs monitor (RVSM) technology , 2001 .

[4]  O. Boric-Lubecke,et al.  Heart Rate Variability Assessment Using Doppler Radar with Linear Demodulation , 2008, 2008 38th European Microwave Conference.

[5]  James C. Lin,et al.  Microwave Apexcardiography , 1979 .

[6]  A Stys,et al.  Current clinical applications of heart rate variability , 1998, Clinical cardiology.

[7]  S. Swarnamani,et al.  Reconstruction of out-of-plane cardiac displacement patterns as observed on the chest wall during various phases of ECG by capacitance transducer , 1991, IEEE Transactions on Biomedical Engineering.

[8]  Jenshan Lin,et al.  Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring , 2004, IEEE Transactions on Microwave Theory and Techniques.

[9]  J.C. Lin Noninvasive microwave measurement of respiration , 1975, Proceedings of the IEEE.

[10]  L. Amaral,et al.  Multifractality in human heartbeat dynamics , 1998, Nature.

[11]  Byung-Kwon Park,et al.  Arctangent Demodulation With DC Offset Compensation in Quadrature Doppler Radar Receiver Systems , 2007, IEEE Transactions on Microwave Theory and Techniques.

[12]  Kun-mu Chen,et al.  An X-Band Microwave Life-Detection System , 1986, IEEE Transactions on Biomedical Engineering.

[13]  H. Stauss,et al.  Heart rate variability. , 2003, American journal of physiology. Regulatory, integrative and comparative physiology.

[14]  P. Strevens Iii , 1985 .

[15]  Emil Jovanov,et al.  Stress monitoring using a distributed wireless intelligent sensor system. , 2003, IEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society.

[16]  Rich Fletcher,et al.  Low-cost differential front-end for Doppler radar vital sign monitoring , 2009, 2009 IEEE MTT-S International Microwave Symposium Digest.

[17]  Olga Boric-Lubecke,et al.  Signal Processing Methods for Doppler Radar Heart Rate Monitoring , 2008 .

[18]  B. Fetics,et al.  Prognostic value of heart rate variability in chronic congestive heart failure (Veterans Affairs' Survival Trial of Antiarrhythmic Therapy in Congestive Heart Failure). , 2002, The American journal of cardiology.

[19]  O. Boric-Lubecke,et al.  Single-channel receiver limitations in Doppler radar measurements of periodic motion , 2006, 2006 IEEE Radio and Wireless Symposium.

[20]  James C. Lin,et al.  Microwave sensing of physiological movement and volume change: a review. , 1992, Bioelectromagnetics.

[21]  Olga Boric-Lubecke,et al.  Wireless technologies in sleep monitoring , 2009, 2009 IEEE Radio and Wireless Symposium.

[22]  Jenshan Lin,et al.  Frequency-tuning technique for remote detection of heartbeat and respiration using low-power double-sideband transmission in the ka-band , 2006, IEEE Transactions on Microwave Theory and Techniques.

[23]  Changzhi Li,et al.  Complex signal demodulation and random body movement cancellation techniques for non-contact vital sign detection , 2008, IMS 2008.

[24]  M. Hilton,et al.  Evaluation of frequency and time-frequency spectral analysis of heart rate variability as a diagnostic marker of the sleep apnoea syndrome , 1999, Medical & Biological Engineering & Computing.

[25]  Jenshan Lin,et al.  A microwave radio for Doppler radar sensing of vital signs , 2001, 2001 IEEE MTT-S International Microwave Sympsoium Digest (Cat. No.01CH37157).

[26]  Olga Boric-Lubecke,et al.  Cancellation of unwanted motion in a handheld Doppler radar used for non-contact life sign monitoring , 2008, 2008 IEEE MTT-S International Microwave Symposium Digest.

[27]  G. Breithardt,et al.  Heart rate variability: standards of measurement, physiological interpretation and clinical use. Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. , 1996 .

[28]  A. Malliani,et al.  Heart rate variability. Standards of measurement, physiological interpretation, and clinical use , 1996 .

[29]  P. Sly,et al.  Laser monitoring of chest wall displacement. , 1997, The European respiratory journal.

[30]  J. M. Lipton,et al.  Effects of three anesthetic induction techniques on heart rate variability. , 1992, Journal of clinical anesthesia.