Fractal analysis features for weak and single-channel upper-limb EMG signals

Electromyography (EMG) signals are the electrical manifestations of muscle contractions. EMG signals may be weak or at a low level when there is only a small movement in the major corresponding muscle group or when there is a strong movement in the minor corresponding muscle group. Moreover, in a single-channel EMG classification identifying the signals may be difficult. However, weak and single-channel EMG control systems offer a very convenient way of controlling human-computer interfaces (HCIs). Identifying upper-limb movements using a single-channel surface EMG also has a number of rehabilitation and HCI applications. The fractal analysis method, known as detrended fluctuation analysis (DFA), has been suggested for the identification of low-level muscle activations. This study found that DFA performs better in the classification of EMG signals from bifunctional movements of low-level and equal power as compared to other successful and commonly used features based on magnitude and other fractal techniques.

[1]  Pere Caminal,et al.  Detrended Fluctuation Analysis of EEG as a Measure of Depth of Anesthesia , 2007, IEEE Transactions on Biomedical Engineering.

[2]  Babita Pandey,et al.  An integrated intelligent computing model for the interpretation of EMG based neuromuscular diseases , 2009, Expert Syst. Appl..

[4]  J. Gitter,et al.  Fractal analysis of the electromyographic interference pattern , 1995, Journal of Neuroscience Methods.

[5]  Pornchai Phukpattaranont,et al.  A Review of Control Methods for Electric Power Wheelchairs Based on Electromyography Signals with Special Emphasis on Pattern Recognition , 2011 .

[6]  N. P. Reddy,et al.  Fractal analysis of surface EMG signals from the biceps. , 1997, International journal of medical informatics.

[7]  Jose Alvarez-Ramirez,et al.  Scaling properties of image textures: A detrending fluctuation analysis approach , 2006 .

[8]  Bruce C. Wheeler,et al.  EMG feature evaluation for movement control of upper extremity prostheses , 1995 .

[9]  Huosheng Hu,et al.  Support Vector Machine-Based Classification Scheme for Myoelectric Control Applied to Upper Limb , 2008, IEEE Transactions on Biomedical Engineering.

[10]  Yanli Meng,et al.  Test nonlinear determinacy of Electromyogram , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[11]  L. Telesca,et al.  Scaling instability in self-potential earthquake-related signals , 2009 .

[12]  Shaojun Xiao,et al.  Fractal dimension of surface EMG and its determinants , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).

[13]  J. Álvarez-Ramírez,et al.  ECG scaling properties of cardiac arrhythmias using detrended fluctuation analysis , 2008, Physiological measurement.

[14]  Sridhar P. Arjunan,et al.  Pattern classification of Myo-Electrical signal during different Maximum Voluntary Contractions: A study using BSS techniques , 2010 .

[15]  J. Rafiee,et al.  Feature extraction of forearm EMG signals for prosthetics , 2011, Expert Syst. Appl..

[16]  Rajesh P. N. Rao,et al.  Real-Time Classification of Electromyographic Signals for Robotic Control , 2005, AAAI.

[17]  H. Stanley,et al.  Effect of trends on detrended fluctuation analysis. , 2001, Physical review. E, Statistical, nonlinear, and soft matter physics.

[18]  Ahmet Alkan,et al.  Identification of EMG signals using discriminant analysis and SVM classifier , 2012, Expert Syst. Appl..

[19]  Brian Litt,et al.  A comparison of waveform fractal dimension algorithms , 2001 .

[20]  Zhizhong Wang,et al.  Detecting nonlinearity of action surface EMG signal , 2001 .

[21]  Bert U Kleine,et al.  Using two-dimensional spatial information in decomposition of surface EMG signals. , 2007, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[22]  R.N. Scott,et al.  A new strategy for multifunction myoelectric control , 1993, IEEE Transactions on Biomedical Engineering.

[23]  V. Witkovský,et al.  Exact Likelihood Ratio Test for the Parameters of the Linear Regression Model with Normal Errors , 2009 .

[24]  Dinesh Kant Kumar,et al.  Classification of low-level finger contraction from single channel surface EMG , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[25]  Kevin B. Englehart,et al.  A wavelet-based continuous classification scheme for multifunction myoelectric control , 2001, IEEE Transactions on Biomedical Engineering.

[26]  A. Phinyomark,et al.  An optimal wavelet function based on wavelet denoising for multifunction myoelectric control , 2009, 2009 6th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology.

[27]  Chia-Hung Lin,et al.  Portable hand motion classifier for multi-channel surface electromyography recognition using grey relational analysis , 2010, Expert Syst. Appl..

[28]  Mohammad Hassan Moradi,et al.  Evaluation of the forearm EMG signal features for the control of a prosthetic hand. , 2003, Physiological measurement.

[29]  Chi-Woong Mun,et al.  Comparison of k-nearest neighbor, quadratic discriminant and linear discriminant analysis in classification of electromyogram signals based on the wrist-motion directions , 2011 .

[30]  J. Basmajian Muscles Alive—their functions revealed by electromyography , 1963 .

[31]  A. Phinyomark,et al.  Evaluation of EMG feature extraction for hand movement recognition based on Euclidean distance and standard deviation , 2010, ECTI-CON2010: The 2010 ECTI International Confernce on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology.

[32]  Marie-Françoise Lucas,et al.  Signal-dependent wavelets for electromyogram classification , 2005, Medical & Biological Engineering & Computing.

[33]  Huosheng Hu,et al.  Myoelectric control systems - A survey , 2007, Biomed. Signal Process. Control..

[34]  P. Geethanjali,et al.  Identification of motion from multi-channel EMG signals for control of prosthetic hand , 2011, Australasian Physical & Engineering Sciences in Medicine.

[35]  Dario Farina,et al.  A new method for the extraction and classification of single motor unit action potentials from surface EMG signals , 2004, Journal of Neuroscience Methods.

[36]  Marco Platzner,et al.  Fluctuating emg signals: Investigating long-term effects of pattern matching algorithms , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[37]  Montri Phothisonothai,et al.  Fractal-based EEG data analysis of body parts movement imagery tasks. , 2007, The journal of physiological sciences : JPS.

[38]  A. Phinyomark,et al.  ELECTROMYOGRAPHY (EMG) SIGNAL CLASSIFICATION BASED ON DETRENDED FLUCTUATION ANALYSIS , 2011 .

[39]  H. Stanley,et al.  Quantification of scaling exponents and crossover phenomena in nonstationary heartbeat time series. , 1995, Chaos.

[40]  Dinesh K Kumar,et al.  Use of sEMG in identification of low level muscle activities: Features based on ICA and fractal dimension , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[41]  Dinesh Kant Kumar,et al.  Decoding subtle forearm flexions using fractal features of surface electromyogram from single and multiple sensors , 2010, Journal of NeuroEngineering and Rehabilitation.

[42]  D. Newham,et al.  Fatigue and functional performance of human biceps muscle following concentric or eccentric contractions. , 2007, Journal of applied physiology.

[43]  S Poosapadi Arjunan,et al.  Fractal features of surface electromyogram: a new measure for low level muscle activation , 2008 .

[44]  Roberto Merletti,et al.  Detection and Conditioning of Surface EMG Signals , 2004 .

[45]  Dennis C. Tkach,et al.  Study of stability of time-domain features for electromyographic pattern recognition , 2010, Journal of NeuroEngineering and Rehabilitation.

[46]  V. Roychowdhury,et al.  Assessment of long-range correlation in time series: how to avoid pitfalls. , 2006, Physical review. E, Statistical, nonlinear, and soft matter physics.

[47]  Luciano Telesca,et al.  Long-range dependence in tree-ring width time series of Austrocedrus Chilensis revealed by means of the detrended fluctuation analysis , 2010 .

[48]  J Duchêne,et al.  Surface electromyogram during voluntary contraction: processing tools and relation to physiological events. , 1993, Critical reviews in biomedical engineering.

[49]  K. Nagata,et al.  A Classification Method of Hand Movements Using Multi Channel Electrode , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[50]  Ping Zhou,et al.  Decoding a new neural machine interface for control of artificial limbs. , 2007, Journal of neurophysiology.

[51]  Roberto Merletti,et al.  Control of Powered Upper Limb Prostheses , 2004 .

[52]  Space-magnitude dependent scaling behaviour in seismic interevent series revealed by detrended fluctuation analysis , 2008 .