Neuromagnetic field strength outside the human head due to impedance changes from neuronal depolarization.

The holy grail of neuroimaging would be to have an imaging system, which could image neuronal electrical activity over milliseconds. One way to do this would be by imaging the impedance changes associated with ion channels opening in neuronal membranes in the brain during activity. In principle, we could measure this change by using electrical impedance tomography (EIT) but it is close to its threshold of detectability. With the inherent limitation in the use of electrodes, we propose a new scheme based on recording the magnetic field resulting from an injected current with superconducting quantum interference devices (SQUIDs), used in magnetoencephalography (MEG). We have performed a feasibility study using computer simulation. The head was modelled as concentric spheres to mimic the scalp, skull, cerebrospinal fluid and brain using the finite element method. The magnetic field 1 cm away from the scalp was estimated. An impedance change of 1% in a 2 cm radius volume in the brain was modelled as the region of depolarization. A constant current of 100 microA was injected into the head from diametrically opposite electrodes. The model predicts that the standing magnetic field is about 10 pT and changed by about 3 fT (0.03%) on depolarization. The spectral noise density in a typical MEG system in the frequency band 1-100 Hz is about 7 fT, so this places the change at the limit of detectability. This is similar to electrical recording, as in conventional EIT systems, but there may be advantages to MEG in that the magnetic field directly traverses the skull and instrumentation errors from the electrode-skin interface will be obviated.

[1]  D S Holder,et al.  Some practical biological phantoms for calibrating multifrequency electrical impedance tomography. , 1996, Physiological measurement.

[2]  R M Heethaar,et al.  Improvement of cardiac imaging in electrical impedance tomography by means of a new electrode configuration. , 1996, Physiological measurement.

[3]  D. Purves,et al.  Correlated Size Variations in Human Visual Cortex, Lateral Geniculate Nucleus, and Optic Tract , 1997, The Journal of Neuroscience.

[4]  R J Ilmoniemi,et al.  Spatiotemporal activity of a cortical network for processing visual motion revealed by MEG and fMRI. , 1999, Journal of neurophysiology.

[5]  K. Hossmann,et al.  Cortical steady potential, impedance and excitability changes during and after total ischemia of cat brain. , 1971, Experimental neurology.

[6]  C. Terzuolo,et al.  Membrane currents in spinal motoneurons associated with the action potential and synaptic activity. , 1962, Journal of neurophysiology.

[7]  J. Bodurka,et al.  Toward direct mapping of neuronal activity: MRI detection of ultraweak, transient magnetic field changes , 2002 .

[8]  L. Geddes,et al.  The specific resistance of biological material—A compendium of data for the biomedical engineer and physiologist , 1967, Medical and biological engineering.

[9]  A. Hansen,et al.  Brain extracellular space during spreading depression and ischemia. , 1980, Acta physiologica Scandinavica.

[10]  D. Cohen Magnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm Currents , 1968, Science.

[11]  M. Hämäläinen Magnetoencephalography: A tool for functional brain imaging , 2005, Brain Topography.

[12]  R H Bayford,et al.  Electrical impedance tomography of human brain activity with a two-dimensional ring of scalp electrodes , 2001, Physiological measurement.

[13]  D S Holder,et al.  Design considerations and performance of a prototype system for imaging neuronal depolarization in the brain using 'direct current' electrical resistance tomography. , 1995, Physiological measurement.

[14]  R. Ilmoniemi,et al.  Magnetoencephalography-theory, instrumentation, and applications to noninvasive studies of the working human brain , 1993 .

[15]  Myers Re,et al.  Changes in cortical impedance and EEG activity induced by profound hypotension. , 1975 .

[16]  J. Sarvas Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem. , 1987, Physics in medicine and biology.

[17]  A Tizzard,et al.  Solving the forward problem in electrical impedance tomography for the human head using IDEAS (integrated design engineering analysis software), a finite element modelling tool , 2001, Physiological measurement.

[18]  D S Holder,et al.  Imaging of physiologically evoked responses by electrical impedance tomography with cortical electrodes in the anaesthetized rabbit. , 1996, Physiological measurement.

[19]  Kenneth S. Cole,et al.  MEMBRANE AND PROTOPLASM RESISTANCE IN THE SQUID GIANT AXON , 1939, The Journal of general physiology.

[20]  Simon R. Arridge,et al.  A method for three‐dimensional time‐resolved optical tomography , 2000 .

[21]  Eung Je Woo,et al.  A robust image reconstruction algorithm and its parallel implementation in electrical impedance tomography , 1993, IEEE Trans. Medical Imaging.