Studying the indoor air quality in three non-residential environments of different use: A museum, a

Abstract The aim of the present study was to identify the main sources contributing to the air pollution of three indoor environments of different use: a museum, a printery industry and an office. For that purpose, particulate matter (TSP, PM 10 , PM 2.5 ), inorganic pollutants (NO x , SO 2 , O 3 ) and organic compounds (BTX, formaldehyde) were monitored. Factors such as the kind of the activities occurred indoors, the emissions from the existing equipment, the number of occupants, the ventilation pattern and the outdoor background substantially varied among the three sites. The average values of PM 2.5 (151 μg m −3 ), benzene (69.4 μg m −3 ), toluene (147 μg m −3 ), SO 2 (47 μg m −3 ) and NO 2 (96.6 μg m −3 ) were the highest values recorded during the experimental campaigns while all of them measured in the printery industry. Formaldehyde presented the highest concentration value in the museum (50.5 μg m −3 ). O 3 was measured to have the highest concentration in the non smokers’ office (238 μg m −3 ) while the lowest was found in the presser section of the printer industry (11.0 μg m −3 ). The location of the sites seems to play a significant role, too. Benzene/toluene ratio indicated traffic as a major source. Furthermore, ozone presented low levels in the printery and the museum (urban area) and relatively higher levels in offices (suburban area), indicating its outdoor origin.

[1]  Antonella Zanobetti,et al.  Air conditioning and source-specific particles as modifiers of the effect of PM(10) on hospital admissions for heart and lung disease. , 2001, Environmental health perspectives.

[2]  J. Hlavay,et al.  Toluene−Benzene Concentration Ratio as a Tool for Characterizing the Distance from Vehicular Emission Sources , 1997 .

[3]  Chia-wei Lee,et al.  Characteristics and health impacts of volatile organic compounds in photocopy centers. , 2006, Environmental research.

[4]  D. Dockery,et al.  Increased Particulate Air Pollution and the Triggering of Myocardial Infarction , 2001, Circulation.

[5]  Shuji Fujii,et al.  Indoor air quality for chemical and ultrafine particle contaminants from printers , 2007 .

[6]  Andrew P. Jones,et al.  Indoor air quality and health , 1999 .

[7]  J. Michopoulos,et al.  Temporal variations of PM2.5 in the ambient air of a suburban site in Athens, Greece. , 2005, The Science of the total environment.

[8]  A. Afshari,et al.  Characterization of indoor sources of fine and ultrafine particles: a study conducted in a full-scale chamber. , 2005, Indoor air.

[9]  S. Masunaga,et al.  Ambient levels of volatile organic compounds in the vicinity of petrochemical industrial area of Yokohama, Japan , 2009, Air quality, atmosphere, & health.

[10]  J. Bartzis,et al.  Indoor exposure from building materials: A field study , 2010 .

[11]  Kelly W Leovic,et al.  Measurement of Indoor Air Emissions from Dry-Process Photocopy Machines. , 1996, Journal of the Air & Waste Management Association.

[12]  R. Schlacher,et al.  Formaldehyde--study of indoor air pollution in Austria. , 1997, Central European journal of public health.

[13]  H. Bravo,et al.  Concentrations of benzene and toluene in the atmosphere of the southwestern area at the Mexico City Metropolitan Zone , 2002 .

[14]  L. Morawska,et al.  Contribution from indoor sources to particle number and mass concentrations in residential houses , 2004 .

[15]  Małgorzata Pośniak,et al.  Volatile Organic Compounds in the Indoor Air of Warsaw Office Buildings , 2005 .

[16]  J. Ring,et al.  Influence of airborne nitrogen dioxide or formaldehyde on parameters of skin function and cellular activation in patients with atopic eczema and control subjects. , 1998, The Journal of allergy and clinical immunology.

[17]  Lance Wallace,et al.  Continuous Monitoring of Ultrafine, Fine, and Coarse Particles in a Residence for 18 Months in 1999-2000 , 2002, Journal of the Air & Waste Management Association.

[18]  Francesco Forastiere,et al.  Air Pollution and Myocardial Infarction in Rome: A Case-Crossover Analysis , 2003, Epidemiology.

[19]  Tracy L. Thatcher,et al.  Deposition, resuspension, and penetration of particles within a residence , 1995 .

[20]  M Luoma,et al.  Characterization of particulate emissions from occupant activities in offices. , 2001, Indoor air.

[21]  Chris T. Kiranoudis,et al.  Mathematical modeling of environmental conditions inside historical buildings. The case of the archaeological museum of Athens , 2000 .

[22]  Alvin C.K. Lai,et al.  Modeling of airborne particle exposure and effectiveness of engineering control strategies , 2004 .

[23]  Jakub Ondráček,et al.  Characterization of particulate matter concentrations during controlled indoor activities , 2010 .

[24]  S. K. Brown,et al.  Assessment of pollutant emissions from dry-process photocopiers. , 1999, Indoor air.

[25]  J. Michopoulos,et al.  Assessment Of Traffic Air Pollution UsingCombined Traffic, Air Pollution AndMeteorological Data In The City Of Athens , 2004 .

[26]  Linda Sheldon,et al.  Evaluation of a Test Method for Measuring Indoor Air Emissions from Dry-Process Photocopiers. , 1998, Journal of the Air & Waste Management Association.