A Review on Electrical Capacitance Tomography Sensor Development

Electrical Capacitance Tomography (ECT) detects changes in the distribution of transparency in enclosed areas or pipes. Until now, various methods have been used to determine the optimum ECT sensor for a particular application. Some important parameters that affect the sensitivity of the sensor cannot be ignored. Design factors discussed in this paper study the needs in industry by producing the best image, without affecting the operation of the process. From previous studies many parameters influence the quality and effectiveness of an ECT sensor. The parameters that play important roles in ECT sensor design include the thickness and type of material in the pipe wall between the electrodes and the sensing zone, the thickness and material of the pipe wall separating the electrodes and the screen, the size of the electrodes, the guarding used, example radial guards or plane axial guards, and whether end guards are used. Other matters of concern regarding the dimension and the distance between the electrodes with guardians it is important design factor. Electrodes positioned either inside or outside the vessel will affect the cost factor design to the type of system to be used. This overview of the study is a basic guide for the essential requirements for an ECT sensor system design.

[1]  G. Bolton,et al.  A Review of Recent Electrical Resistance Tomography (ERT) Applications for Wet Particulate Processing , 2008 .

[2]  Hai-Feng Ji,et al.  A high-speed data acquisition system for ECT based on the differential sampling method , 2005, IEEE Sensors Journal.

[3]  Deyun Chen,et al.  Analysis of Performance and Capacitance Sensitivity Distributions of Sensor for Electrical Capacitance Tomography System , 2006, 2006 6th World Congress on Intelligent Control and Automation.

[4]  R.A. Williams,et al.  A high-performance EIT system , 2005, IEEE Sensors Journal.

[5]  Deyun Chen,et al.  Optimized design and simulation of electrical capacitance sensor for electrical capacitance tomography system , 2002, SPIE ITCom.

[6]  S. Khan,et al.  Computer Aided Design of Process Tomography Capacitance Electrode System for Flow Imaging , 1991 .

[7]  Ruzairi Abdul Rahim,et al.  Electric Potential of Various 4-electrode Segmentation Excitation for Electrical Capacitance Tomography System , 2014 .

[8]  Wuqiang Yang,et al.  Key issues in designing capacitance tomography sensors , 2006, 2006 5th IEEE Conference on Sensors.

[9]  Sharath Subash Donthi Capacitance based Tomography for Industrial Applications , 2004 .

[10]  A. Martínez Olmos,et al.  Influence of Shielding Arrangement on ECT Sensors , 2006 .

[11]  Todd Pugsley,et al.  The dynamic calibration of an electrical capacitance tomography sensor applied to the fluidized bed drying of pharmaceutical granule , 2005 .

[12]  Wuqiang Yang Modelling of capacitance tomography sensors , 1997 .

[13]  Yan Hua,et al.  Three-dimensional analysis of electrical capacitance tomography sensing fields , 1999 .

[14]  Chen De-yun Integrated Electrodes for Electrical Capacitance Tomography , 2004 .

[15]  Tom Dyakowski,et al.  Imaging nylon polymerisation processes by applying electrical tomography , 2000 .

[16]  Maurice Beck,et al.  Tomographic imaging of two-component flow using capacitance sensors , 1989 .

[17]  Zhiyao Huang,et al.  A high-speed data acquisition system for ECT based on the differential sampling method , 2005 .

[18]  Martin Winter,et al.  Composite supercapacitor electrodes , 2003 .

[19]  Fazlul Rahman Mohd Yunus,et al.  Hardware Development Of Electrical Capacitance Tomography For Imaging A Mixture Of Water And Oil , 2008 .

[20]  Paul Horowitz,et al.  The Art of Electronics , 1980 .

[21]  Wuqiang Yang,et al.  Calibration of capacitance tomography systems: a new method for setting system measurement range , 1996 .

[22]  Brian S. Hoyle,et al.  Electrical capacitance tomography for flow imaging: system model for development of image reconstruction algorithms and design of primary sensors , 1992 .

[23]  Wuqiang Yang,et al.  Tomography for multi-phase flow measurement in the oil industry , 2005 .

[24]  R. Thorn,et al.  Flow imaging for multi-component flow measurement , 1990 .

[25]  George W. Bohrnstedt,et al.  Special Issue on Measurement , 1980 .

[26]  Wuqiang Yang,et al.  Adaptive calibration of a capacitance tomography system for imaging water droplet distribution , 2004 .

[27]  Richard A Williams,et al.  Process tomography : principles, techniques and applications , 1995 .

[28]  Sun Li-quan Simulation of Sensors and Image Reconstruction Algorithm Based on Genetic Algorithms for Electrical Capacitance Tomography System , 2004 .

[29]  Wuqiang Yang,et al.  Electrical capacitance tomography sensor with internal-external electrodes , 2001, SPIE Optics East.

[30]  H. Yan,et al.  Fast calculation of sensitivity distributions in capacitance tomography sensors , 1998 .

[31]  Tomasz Dyakowski,et al.  RAPID COMMUNICATION: A capacitance probe for interface detection in oil and gas extraction plant , 1999 .