Simulation Models For Three-Phase Grid Connected PV Inverters Enabling Current Limitation Under Unbalanced Faults

Normally unbalanced grid voltage dips may lead to unbalanced non-sinusoidal current injections, DC-link voltage oscillations, and active and/or reactive power oscillations with twice the grid fundamental frequency in three-phase grid-connected Photovoltaic (PV) systems. Double grid frequency oscillations at the DC-link of the conventional two-stage PV inverters can further deteriorate the DC-link capacitor, which is one of the most important limiting components in the system. Proper control of these converters may efficiently address this problem. In such solutions, Current Reference Calculation (CRC) is one of the most important issues that should be coped with the reliable operation of grid-connected converters under unbalanced grid faults. Therefore, this paper proposes and simulates CRC methods and presents the results in order to improve the quality of the grid-connected PV system under unbalanced grid voltage fault.

[1]  Marco Liserre,et al.  New Positive-sequence Voltage Detector for Grid Synchronization of Power Converters under Faulty Grid Conditions , 2006 .

[2]  Tran Quoc Tuan,et al.  Effects of DFIG wind power generation on Vietnam power system operation , 2015, 2015 IEEE Eindhoven PowerTech.

[3]  Xiao-Ping Zhang,et al.  PI Parameters Determination in dq Decoupling Control of VSC Terminals , 2017 .

[4]  Fazal Wahab Karam,et al.  Mitigating the Adverse Impact of Un-Deterministic Distributed Generation on a Distribution System Considering Voltage Profile , 2018, Engineering, Technology & Applied Science Research.

[5]  A. Babaie Lajimi,et al.  Modeling and Control of a DFIG-Based Wind Turbine During a Grid Voltage Drop , 2011 .

[6]  Tamer Khatib,et al.  Modeling of Photovoltaic Systems Using MATLAB: Simplified Green Codes , 2016 .

[7]  Marco Liserre,et al.  Grid Converters for Photovoltaic and Wind Power Systems , 2011 .

[8]  O. Gomis-Bellmunt,et al.  Current Control Reference Calculation Issues for the Operation of Renewable Source Grid Interface VSCs Under Unbalanced Voltage Sags , 2011, IEEE Transactions on Power Electronics.

[9]  Reza Iravani,et al.  Voltage-Sourced Converters in Power Systems: Modeling, Control, and Applications , 2010 .

[10]  N. Martins,et al.  Three-phase power flow calculations using the current injection method , 2000 .

[11]  Jahangir Hossain,et al.  Renewable energy integration: challenges and solutions , 2014 .

[12]  Frede Blaabjerg,et al.  Control Strategy for Three-Phase Grid-Connected PV Inverters Enabling Current Limitation Under Unbalanced Faults , 2017, IEEE Transactions on Industrial Electronics.

[13]  Frede Blaabjerg,et al.  Reliability of Capacitors for DC-Link Applications in Power Electronic Converters—An Overview , 2014, IEEE Transactions on Industry Applications.

[14]  B. Banerjee,et al.  Assessment of Voltage Unbalance , 2001, IEEE Power Engineering Review.

[15]  Oriol Gomis Bellmunt,et al.  Active and reactive power control of grid connected distributed generation systems , 2012 .

[16]  Oriol Gomis-Bellmunt,et al.  Active and Reactive Power Control of Grid Connected Distributed Generation Systems , 2012 .

[17]  Nguyen Huu Hieu,et al.  Using double Fed induction generator to enhance voltage stability and solving economic issue , 2016, 2016 IEEE International Conference on Sustainable Energy Technologies (ICSET).

[18]  Arindam Ghosh,et al.  Voltage Unbalance reduction in low voltage distribution networks with rooftop PVs , 2010, 2010 20th Australasian Universities Power Engineering Conference.