Hard x-ray imager onboard Hitomi (ASTRO-H)

Abstract. The hard x-ray imaging spectroscopy system of “Hitomi” x-ray observatory is composed of two sets of hard x-ray imagers (HXI) coupled with hard x-ray telescopes (HXT). With a 12-m focal length, the system provides fine (1  ′    .  7 half-power diameter) imaging spectroscopy covering about 5 to 80 keV. The HXI sensor consists of a camera, which is composed of four layers of Si and one layer of CdTe semiconductor imagers, and an active shield composed of nine Bi4Ge3O12 scintillators to provide low background. The two HXIs started observation on March 8 and 14, 2016 and were operational until 26 March. Using a Crab observation, 5 to 80 keV energy coverage and good detection efficiency were confirmed. The detector background level of 1 to 3  ×  10  −  4  counts s  −  1 keV  −  1 cm  −  2 (in detector geometrical area) at 5 to 80 keV was achieved, by cutting the high-background time-intervals, adopting sophisticated energy-dependent imager layer selection, and baffling of the cosmic x-ray background and active-shielding. This level is among the lowest of detectors working in this energy band. By comparing the effective area and the background, it was shown that the HXI had a sensitivity that is same to that of NuSTAR for point sources and 3 to 4 times better for largely extended diffuse sources.

[1]  Yoshiharu Namba,et al.  Performance of ASTRO-H hard x-ray telescope (HXT) , 2016, Astronomical Telescopes + Instrumentation.

[2]  Tadayuki Takahashi,et al.  Hard x-ray imager for the NeXT mission , 2006, SPIE Astronomical Telescopes + Instrumentation.

[3]  Kristin K. Madsen,et al.  NuSTAR OBSERVATIONS OF THE BULLET CLUSTER: CONSTRAINTS ON INVERSE COMPTON EMISSION , 2014, 1403.2722.

[4]  T. Takahashi,et al.  High Energy Resolution Hard X-Ray and Gamma-Ray Imagers Using CdTe Diode Devices , 2009, IEEE Transactions on Nuclear Science.

[5]  William W. Zhang,et al.  THE NUCLEAR SPECTROSCOPIC TELESCOPE ARRAY (NuSTAR) HIGH-ENERGY X-RAY MISSION , 2013, Astronomical Telescopes and Instrumentation.

[7]  Yasushi Fukazawa,et al.  Modeling of proton-induced radioactivation background in hard X-ray telescopes: Geant4-based simulation and its demonstration by Hitomi’s measurement in a low Earth orbit , 2018, 1804.00827.

[8]  Kentaro Uesugi,et al.  Imaging and spectral performance of CdTe double-sided strip detectors for the hard x-ray imager onboard ASTRO-H , 2012, Other Conferences.

[9]  T. Tanaka,et al.  In-Orbit Performance of the Hard X-Ray Detector on Board Suzaku , 2006, astro-ph/0611233.

[10]  Yasushi Fukazawa,et al.  Spectral Variation of Hard X-Ray Emission from the Crab Nebula with the Suzaku Hard X-Ray Detector , 2013 .

[11]  T. Takahashi,et al.  Performance of a low noise front-end ASIC for Si/CdTe detectors in Compton gamma-ray telescope , 2004, IEEE Transactions on Nuclear Science.

[12]  Tadayuki Takahashi,et al.  Development and verification of signal processing system of BGO active shield onboard Astro-H , 2014, Astronomical Telescopes and Instrumentation.

[13]  Matteo Guainazzi,et al.  Glimpse of the highly obscured HMXB IGR J16318−4848 with Hitomi , 2017, 1711.07727.

[14]  Yasushi Fukazawa,et al.  Modeling and Reproducibility of Suzaku HXD PIN/GSO Background , 2009, 0901.0419.

[15]  Olivier Limousin,et al.  A laboratory test setup to study the stability of operation of the CdTe detectors within Astro-H HXI , 2016, Astronomical Telescopes + Instrumentation.

[16]  Yasushi Fukazawa,et al.  Development of double-sided silicon strip detectors (DSSD) for a Compton telescope , 2007 .

[17]  Geometry dependence of the light collection efficiency of BGO crystal scintillators read out by avalanche photo diodes , 2013 .

[18]  Goro Sato,et al.  Study of polarization phenomena in Schottky CdTe diodes using infrared light illumination , 2011 .

[19]  Yasushi Fukazawa,et al.  Development of high performance Avalanche Photodiodes and dedicated analog systems for HXI/SGD detectors onboard the Astro-H mission , 2013 .

[20]  Kristin K. Madsen,et al.  Measurement of the Absolute Crab Flux with NuSTAR , 2017, 1703.10685.

[21]  Tadayuki Takahashi,et al.  Time assignment system and its performance aboard the Hitomi satellite , 2017, 1712.01484.

[22]  Kazuhiro Nakazawa,et al.  Thermal design of the hard x-ray imager and the soft gamma-ray detector onboard ASTRO-H , 2014, Astronomical Telescopes and Instrumentation.

[23]  Tadayuki Takahashi,et al.  The Hard X-ray Imager (HXI) for the ASTRO-H mission , 2012, Other Conferences.

[24]  Shogo B. Kobayashi,et al.  The Si/CdTe semiconductor camera of the ASTRO-H Hard X-ray Imager (HXI) , 2016 .

[25]  Yasushi Fukazawa,et al.  Development of low-noise double-sided silicon strip detector for cosmic soft gamma-ray compton camera , 2005 .

[26]  Tuneyoshi Kamae,et al.  Hard X-Ray Detector (HXD) on Board Suzaku , 2006, astro-ph/0611232.

[27]  Hideyuki Mori,et al.  Inorbit performance of the Hard X-ray Telescope (HXT) on board the Hitomi (ASTRO-H) satellite , 2018, 1803.00242.

[28]  Yasushi Fukazawa,et al.  Design and In-Orbit Performance of the Suzaku Wide-Band All-Sky Monitor , 2009 .

[29]  Yoshiharu Namba,et al.  The ASTRO-H Mission , 2009, Astronomical Telescopes + Instrumentation.

[30]  Yoshiharu Namba,et al.  The ASTRO-H (Hitomi) x-ray astronomy satellite , 2016, Astronomical Telescopes + Instrumentation.