Determination of the Avogadro constant by the XRCD method using a 28Si-enriched sphere

To determine the Avogadro constant N A by the x-ray crystal density method, the density of a 28Si-enriched crystal was determined by absolute measurements of the mass and volume of a 1 kg sphere manufactured from the crystal. The mass and volume were determined by an optical interferometer and a vacuum mass comparator, respectively. The sphere surface was characterized by x-ray photoelectron spectroscopy and spectroscopic ellipsometry to derive the mass and volume of the Si core of the sphere excluding the surface layers. From the mass and volume, the density of the Si core was determined with a relative standard uncertainty of 2.3 × 10−8. By combining the Si core density with the lattice constant and the molar mass of the sphere reported by the International Avogadro Coordination (IAC) project in 2015, a new value of 6.022 140 84(15) × 1023 mol−1 was obtained for N A with a relative standard uncertainty of 2.4 × 10−8. To make the N A value determined in this work usable for a future adjustment of the fundamental constants by the CODATA Task Group on Fundamental Constants, the correlation of the new N A value with the N A values determined in our previous works was examined. The correlation coefficients with the values of N A determined by IAC in 2011 and 2015 were estimated to be 0.07 and 0.28, respectively. The correlation of the new N A value with the N A value determined by IAC in 2017 using a different 28Si-enriched crystal was also examined, and the correlation coefficient was estimated to be 0.21.

[1]  Naoki Kuramoto,et al.  Surface Layer Analysis of a 28Si-Enriched Sphere Both in Vacuum and in Air by Ellipsometry , 2017, IEEE Transactions on Instrumentation and Measurement.

[2]  Kenichi Fujii,et al.  Volume measurements of 28Si spheres using an interferometer with a flat etalon to determine the Avogadro constant , 2011 .

[3]  Michael Stock,et al.  A brief history of the unit of mass: continuity of successive definitions of the kilogram , 2016 .

[4]  S Mizushima,et al.  Determination of the amount of gas adsorption on SiO2/Si(100) surfaces to realize precise mass measurement , 2004 .

[5]  Arnold Nicolaus,et al.  The coefficient of thermal expansion of highly enriched 28Si , 2009 .

[6]  Lulu Zhang,et al.  Mass Measurement of 28Si-Enriched Spheres at NMIJ for the Determination of the Avogadro Constant , 2016, IEEE Transactions on Instrumentation and Measurement.

[7]  Naoki Kuramoto,et al.  Improvements to the Volume Measurement of 28Si Spheres to Determine the Avogadro Constant , 2015, IEEE Transactions on Instrumentation and Measurement.

[8]  Naoki Kuramoto,et al.  Volume measurements of 28Si-enriched spheres using an improved optical interferometer for the determination of the Avogadro constant , 2017 .

[9]  Richard Davis,et al.  The SI unit of mass , 2003 .

[10]  M. Prata,et al.  Neutron activation analysis of the 30Si content of highly enriched 28Si: proof of concept and estimation of the achievable uncertainty , 2014, 1405.7524.

[11]  Naoki Kuramoto,et al.  A new 28Si single crystal: counting the atoms for the new kilogram definition , 2017 .

[12]  C. A. Sanchez,et al.  Corrigendum to the 2014 NRC determination of Planck’s constant , 2015 .

[13]  B. Taylor,et al.  CODATA Recommended Values of the Fundamental Physical Constants: 2010 | NIST , 2007, 0801.0028.

[14]  Kenichi Fujii,et al.  Phase corrections in the optical interferometer for Si sphere volume measurements at NMIJ , 2011 .

[15]  Yasushi Azuma,et al.  Counting the atoms in a 28Si crystal for a new kilogram definition , 2011 .

[16]  Michael Krystek,et al.  Current State of Avogadro ${}^{28}$Si sphere S8 , 2013, IEEE Transactions on Instrumentation and Measurement.

[17]  G. Girard,et al.  INTERNATIONAL REPORT: The Third Periodic Verification of National Prototypes of the Kilogram (1988-1992) , 1994 .

[18]  B. Taylor,et al.  CODATA Recommended Values of the Fundamental Physical Constants 1998*$\dagger$ , 1999 .

[19]  Naoki Kuramoto,et al.  Realization of the kilogram by the XRCD method , 2016 .

[20]  Richard Davis,et al.  Towards a new SI: a review of progress made since 2011 , 2014 .

[21]  S. Mizushima,et al.  Establishment of the platinum–iridium kilogram mass standards at NMIJ after the Extraordinary Calibrations , 2016 .

[22]  Kenichi Fujii,et al.  The uncertainty of the phase-correction in sphere-diameter measurements , 2012 .

[23]  Michael Krystek,et al.  Volume determination of the Avogadro spheres of highly enriched 28Si with a spherical Fizeau interferometer , 2011 .

[24]  Lulu Zhang,et al.  Realization of the Kilogram Based on the Planck Constant at NMIJ , 2016, IEEE Transactions on Instrumentation and Measurement.

[25]  K. Fujii,et al.  Molar-mass measurement of a 28Si-enriched silicon crystal for determination of the Avogadro constant , 2014 .

[26]  G. Turk,et al.  Absolute silicon molar mass measurements, the Avogadro constant and the redefinition of the kilogram , 2014 .

[27]  Lulu Zhang,et al.  Thickness Measurement of Oxide and Carbonaceous Layers on a 28Si Sphere by XPS , 2017, IEEE Transactions on Instrumentation and Measurement.

[28]  Peter J. Mohr,et al.  CODATA recommended values of the fundamental constants , 2001 .

[29]  H. Riemann,et al.  The Avogadro constant determination via enriched silicon-28 , 2009 .

[30]  S Schlamminger,et al.  Invited Article: A precise instrument to determine the Planck constant, and the future kilogram , 2016, The Review of scientific instruments.

[31]  M. Borys,et al.  The Correlation of the NA Measurements by Counting 28Si Atoms , 2015, 1512.06138.

[32]  Michael Stock,et al.  Calibration campaign against the international prototype of the kilogram in anticipation of the redefinition of the kilogram part I: comparison of the international prototype with its official copies , 2015 .

[33]  I Busch,et al.  Improved measurement results for the Avogadro constant using a 28Si-enriched crystal , 2015, 1512.05642.

[34]  M. Milton,et al.  Calibration campaign against the international prototype of the kilogram in anticipation of the redefinition of the kilogram, part II: evolution of the BIPM as-maintained mass unit from the 3rd periodic verification to 2014 , 2016 .

[35]  Yasushi Azuma,et al.  Surface layer determination for the Si spheres of the Avogadro project , 2011 .

[36]  Stefan Kedenburg,et al.  Linear refractive index and absorption measurements of nonlinear optical liquids in the visible and near-infrared spectral region , 2012 .

[37]  G. Mana,et al.  A More Accurate Measurement of the 28Si Lattice Parameter , 2015 .