Studies of VOCs removed from packed-bed absorber by experimental design methodology and analysis of variance

Abstract Indoor air quality is affected by volatile organic compound (VOC) pollutants and these are often emitted by furniture and building materials. To enhance indoor air quality, removing VOCs from indoor environment is an important task. Triethylene glycol (TEG) solution was used as working solution to absorb VOCs from ambient air in this study. Plastic 5/8 in. polaring-type was packed in the packed-bed absorber, and the packed length was about 34 cm. Toluene, methanol, ethyl ether, and methyl-ethyl ketone were absorbed separately by TEG solution. Two-level factorial experimental design methodology was applied to schedule the operating variables in the experiment. The advantage of experimental design methodology is to obtain reasonable experimental results with fewer experimental runs. In addition, the analysis of variance (ANOVA) was used to analyze the effect of operating variables (factors) on mass transfer coefficient (response). The p -value was used to assess the mass transfer performance of VOCs absorbed by packed-bed absorber. From experimental results, effect of air flux on mass transfer coefficient was significant except for methanol because the p -values were smaller than 0.1 for toluene, ethyl ether, and ketone. For VOCs concentration, the effect of methanol concentration on mass transfer coefficient was extremely significant; the effect of concentration of ethyl ether was very significant; the effect of concentration of toluene was significant; the effect of methyl-ethyl ketone was insignificant. Since all the p -values were smaller than 0.01 for liquid flux, the effect of liquid flux on mass transfer coefficient was very significant. By analyzing the factorial interaction, the factorial couples, toluene concentration × liquid flux, TEG concentration × methanol concentration, TEG concentration × ethyl ether concentration, and ketone concentration × liquid flux can be chosen as main variables to operate the absorption system for absorption of toluene, methanol, ethyl ether, and ketone to acquire the desired mass transfer coefficient.

[1]  D. A. Kouremenos,et al.  Predicted performance of solar driven H2OLiBr absorption units in Athens , 1989 .

[2]  J. Joshi,et al.  Absorption of NOx gases in plate column : Selective manufacture of sodium nitrite , 2000 .

[3]  Francesco Pepe,et al.  Modeling of SO2 Absorption into Limestone Suspensions , 1997 .

[4]  Allan G. Bluman Elementary Statistics: A Step By Step Approach , 1980 .

[5]  S. C. Kaushik,et al.  Thermal modelling and parametric study of two stage absorption refrigeration and air-conditioning systems , 1985 .

[6]  A. Lohi,et al.  A new liquid distribution factor and local mass transfer coefficient in a random packed bed , 2006 .

[7]  I. D. Mall,et al.  Multicomponent adsorption study of metal ions onto bagasse fly ash using taguchi's design of experimental methodology , 2007 .

[8]  Terry G. Lenz,et al.  Dimensionless mass-transfer correlations for packed-bed liquid-desiccant contactors , 1996 .

[9]  Tsair-Wang Chung,et al.  Comparison between Random and Structured Packings for Dehumidification of Air by Lithium Chloride Solutions in a Packed Column and Their Heat and Mass Transfer Correlations , 1996 .

[10]  Haroldo de Araújo Ponte,et al.  Study of the operational parameters involved in designing a particle bed reactor for the removal of lead from industrial wastewater — central composite design methodology , 2005 .

[11]  Martin Zidar Gas−Liquid Equilibrium-Operational Diagram: Graphical Presentation of Absorption of SO2 in the NaOH−SO2−H2O System Taking Place within a Laboratory Absorber , 2000 .

[12]  Bing Qi,et al.  Performance of a fungal biofilter treating gas-phase solvent mixtures during intermittent loading. , 2004, Water research.

[13]  Sabah A. Abdul-Wahab,et al.  Air dehumidification by triethylene glycol desiccant in a packed column , 2004 .

[14]  D. A. Kouremenos,et al.  A high-efficiency, compound NH3/H2O-H2O/LiBr absorption-refrigeration system , 1989 .

[15]  Asterios Gavriilidis,et al.  Carbon dioxide absorption in a falling film microstructured reactor : Experiments and modeling , 2005 .

[16]  D. Mazyck,et al.  Microwave-Assisted Preparation of TiO2/Activated Carbon Composite Photocatalyst for Removal of Methanol in Humid Air Streams , 2006 .

[17]  M. Eyvazi,et al.  Effect of liquid distribution on the organic removal in a trickle bed filter , 2008 .

[18]  Yong Jin,et al.  Mass transfer coefficient for two-phase countercurrent flow in a packed column with a novel internal , 2004 .

[19]  V. Linek,et al.  Design of packed aeration towers to strip volatile organic contaminants from water , 1998 .

[20]  Honda Wu,et al.  Mass Transfer Correlation for Dehumidification of Air in a Packed Absorber with an Inverse U-Shaped Tunnel , 2000 .

[21]  André M. Braun,et al.  Industrial waste water treatment: large scale development of a light-enhanced Fenton reaction , 1997 .

[22]  Gerald Keller,et al.  Statistics for Management and Economics , 1990 .

[23]  Esam Elsarrag,et al.  Moisture removal rate for air dehumidification by triethylene glycol in a structured packed column , 2007 .

[24]  Robert N. Maddox,et al.  Mass Transfer: Fundamentals and Applications , 1984 .

[25]  M. Paquot,et al.  Use of a Plackett-Burman experimental design to examine the impact of extraction parameters on yields and compositions of pectins extracted from chicory roots (Chicorium intybus L.). , 2006, Journal of agricultural and food chemistry.

[26]  Karl T. Chuang,et al.  CFD modeling of mass-transfer processes in randomly packed distillation columns , 2000 .

[27]  Dehumidification of Air by Aqueous Triethylene Glycol Solution in a Spray Tower , 1998 .

[28]  James R. Fair,et al.  Mass transfer in gauze packings , 1985 .

[29]  Tsair-Wang Chung,et al.  Predictions of moisture removal efficiencies for packed-bed dehumidification systems , 1994 .

[30]  Francesco Pepe,et al.  SO2 absorption in a bubbling reactor using limestone suspensions , 1994 .

[31]  D. Y. Goswami,et al.  Experimental Study of the Heat and Mass Transfer in a Packed Bed Liquid Desiccant Air Dehumidifier , 1998 .