Cross-validation and out-of-sample testing of physical activity intensity predictions with a wrist-worn accelerometer.

Wrist-worn accelerometers are gaining popularity for measurement of physical activity. However, few methods for predicting physical activity intensity from wrist-worn accelerometer data have been tested on data not used to create the methods (out-of-sample data). This study utilized two previously collected data sets [Ball State University (BSU) and Michigan State University (MSU)] in which participants wore a GENEActiv accelerometer on the left wrist while performing sedentary, lifestyle, ambulatory, and exercise activities in simulated free-living settings. Activity intensity was determined via direct observation. Four machine learning models (plus 2 combination methods) and six feature sets were used to predict activity intensity (30-s intervals) with the accelerometer data. Leave-one-out cross-validation and out-of-sample testing were performed to evaluate accuracy in activity intensity prediction, and classification accuracies were used to determine differences among feature sets and machine learning models. In out-of-sample testing, the random forest model (77.3-78.5%) had higher accuracy than other machine learning models (70.9-76.4%) and accuracy similar to combination methods (77.0-77.9%). Feature sets utilizing frequency-domain features had improved accuracy over other feature sets in leave-one-out cross-validation (92.6-92.8% vs. 87.8-91.9% in MSU data set; 79.3-80.2% vs. 76.7-78.4% in BSU data set) but similar or worse accuracy in out-of-sample testing (74.0-77.4% vs. 74.1-79.1% in MSU data set; 76.1-77.0% vs. 75.5-77.3% in BSU data set). All machine learning models outperformed the euclidean norm minus one/GGIR method in out-of-sample testing (69.5-78.5% vs. 53.6-70.6%). From these results, we recommend out-of-sample testing to confirm generalizability of machine learning models. Additionally, random forest models and feature sets with only time-domain features provided the best accuracy for activity intensity prediction from a wrist-worn accelerometer. NEW & NOTEWORTHY This study includes in-sample and out-of-sample cross-validation of an alternate method for deriving meaningful physical activity outcomes from accelerometer data collected with a wrist-worn accelerometer. This method uses machine learning to directly predict activity intensity. By so doing, this study provides a classification model that may avoid high errors present with energy expenditure prediction while still allowing researchers to assess adherence to physical activity guidelines.

[1]  Pierre Jallon,et al.  Automatic identification of physical activity types and sedentary behaviors from triaxial accelerometer: laboratory-based calibrations are not enough. , 2015, Journal of applied physiology.

[2]  B. Ainsworth,et al.  Estimation of energy expenditure using CSA accelerometers at hip and wrist sites. , 2000, Medicine and science in sports and exercise.

[3]  B. Efron Bootstrap Methods: Another Look at the Jackknife , 1979 .

[4]  Karin A Pfeiffer,et al.  Energy Expenditure Prediction Using Raw Accelerometer Data in Simulated Free Living. , 2015, Medicine and science in sports and exercise.

[5]  G. Jean-Louis,et al.  Sleep detection with an accelerometer actigraph: comparisons with polysomnography , 2001, Physiology & Behavior.

[6]  Gert R. G. Lanckriet,et al.  Objective Assessment of Physical Activity: Classifiers for Public Health. , 2016, Medicine and science in sports and exercise.

[7]  John Staudenmayer,et al.  An artificial neural network to estimate physical activity energy expenditure and identify physical activity type from an accelerometer. , 2009, Journal of applied physiology.

[8]  Alan Godfrey,et al.  Detecting free-living steps and walking bouts: validating an algorithm for macro gait analysis , 2017, Physiological measurement.

[9]  Richard P Troiano,et al.  Evolution of accelerometer methods for physical activity research , 2014, British Journal of Sports Medicine.

[10]  P. Freedson,et al.  Amount of time spent in sedentary behaviors in the United States, 2003-2004. , 2008, American journal of epidemiology.

[11]  P S Freedson,et al.  Calibration of the Computer Science and Applications, Inc. accelerometer. , 1998, Medicine and science in sports and exercise.

[12]  John Staudenmayer,et al.  Direct observation is a valid criterion for estimating physical activity and sedentary behavior. , 2014, Journal of physical activity & health.

[13]  ALEX V. ROWLANDS,et al.  Raw Accelerometer Data Analysis with GGIR R-package: Does Accelerometer Brand Matter? , 2016, Medicine and science in sports and exercise.

[14]  Andrea Mannini,et al.  Activity recognition using a single accelerometer placed at the wrist or ankle. , 2013, Medicine and science in sports and exercise.

[15]  Alberto G. Bonomi,et al.  Identifying Types of Physical Activity With a Single Accelerometer: Evaluating Laboratory-trained Algorithms in Daily Life , 2011, IEEE Transactions on Biomedical Engineering.

[16]  David R Bassett,et al.  2011 Compendium of Physical Activities: a second update of codes and MET values. , 2011, Medicine and science in sports and exercise.

[17]  James M. Pivarnik,et al.  Validation and Comparison of Accelerometers Worn on the Hip, Thigh, and Wrists for Measuring Physical Activity and Sedentary Behavior , 2016, AIMS public health.

[18]  Munni Begum,et al.  Comparison of linear and non-linear models for predicting energy expenditure from raw accelerometer data , 2017, Physiological measurement.

[19]  Rebecca W. Moore,et al.  Reporting accelerometer methods in physical activity intervention studies: a systematic review and recommendations for authors , 2016, British Journal of Sports Medicine.

[20]  Leonard A Kaminsky,et al.  Variability of Objectively Measured Sedentary Behavior. , 2016, Medicine and science in sports and exercise.

[21]  Julien Penders,et al.  Estimating Oxygen Uptake During Nonsteady-State Activities and Transitions Using Wearable Sensors , 2016, IEEE Journal of Biomedical and Health Informatics.

[22]  Bo Dong,et al.  Energy-aware activity classification using wearable sensor networks , 2013, Defense, Security, and Sensing.

[23]  James M. Pivarnik,et al.  Comparison of Activity Type Classification Accuracy from Accelerometers Worn on the Hip, Wrists, and Thigh in Young, Apparently Healthy Adults , 2016 .

[24]  Stewart G Trost,et al.  Comparison of accelerometer cut points for predicting activity intensity in youth. , 2011, Medicine and science in sports and exercise.

[25]  Leonard A Kaminsky,et al.  Estimating relative intensity using individualized accelerometer cutpoints: the importance of fitness level , 2013, BMC Medical Research Methodology.

[26]  Gert R. G. Lanckriet,et al.  Hip and Wrist Accelerometer Algorithms for Free-Living Behavior Classification. , 2016, Medicine and science in sports and exercise.

[27]  D. Baer,et al.  Comparison of two different physical activity monitors , 2007, BMC medical research methodology.

[28]  Kamlesh Khunti,et al.  Intensity Thresholds on Raw Acceleration Data: Euclidean Norm Minus One (ENMO) and Mean Amplitude Deviation (MAD) Approaches , 2016, PloS one.

[29]  J. Staudenmayer,et al.  Methods to estimate aspects of physical activity and sedentary behavior from high-frequency wrist accelerometer measurements. , 2015, Journal of applied physiology.

[30]  Tina L Hurst,et al.  Physical activity classification using the GENEA wrist-worn accelerometer. , 2012, Medicine and science in sports and exercise.

[31]  Dinesh John,et al.  Performance of Activity Classification Algorithms in Free-Living Older Adults. , 2016, Medicine and science in sports and exercise.

[32]  Vinod Chandran,et al.  Ensemble Methods for Classification of Physical Activities from Wrist Accelerometry , 2017, Medicine and science in sports and exercise.

[33]  Johan A. K. Suykens,et al.  Least Squares Support Vector Machine Classifiers , 1999, Neural Processing Letters.

[34]  Kenneth Meijer,et al.  Activity identification using body-mounted sensors—a review of classification techniques , 2009, Physiological measurement.

[35]  John Staudenmayer,et al.  A method to estimate free-living active and sedentary behavior from an accelerometer. , 2014, Medicine and science in sports and exercise.

[36]  Luo Xiao,et al.  An Activity Index for Raw Accelerometry Data and Its Comparison with Other Activity Metrics , 2016, PloS one.

[37]  D R Bassett,et al.  Comparison of MTI Accelerometer Cut-Points for Predicting Time Spent in Physical Activity , 2003, International journal of sports medicine.