WAMS-based online disturbance estimation in interconnected power systems using disturbance observer

In the event of a generator loss or disturbance, the power system frequency declines quickly and overall system stability is at risk. During these scenarios, under frequency load shedding is triggered to restore the power system frequency. The main stage of modern adaptive under frequency load shedding techniques is disturbance estimation. However, the swing equation is widely used in disturbance estimation but has some critical estimation errors. In this paper, instead of using the swing equation we proposed the use of a disturbance observer to estimate the curtailed power. By making use of wide area measurements, a system frequency response model, which is a representative of the whole power system, can be realized in real time. Using different power system states of the developed model, a disturbance observer can be designed as well. The main advantage of the disturbance observer is that it can accurately estimate the disturbance magnitude and its location in a very short time. Further investigations show that by using the disturbance observer disturbances, which occur at the same time or at different times in different areas regardless of the magnitude or size, accurate estimations can be made. To ascertain the efficiency of the proposed scheme, simulations are done for a four-area power system using Matlab/Simulink.

[1]  Hassan Haes Alhelou,et al.  An Optimal Photovoltaic Conversion System for Future Smart Grids , 2018 .

[2]  W. Sattinger,et al.  Application of PMU measurements in Europe TSO approach and experience , 2011, 2011 IEEE Trondheim PowerTech.

[3]  Hassan Haes Alhelou,et al.  Hierarchical plug-in EV control based on primary frequency response in interconnected smart grid , 2016, 2016 24th Iranian Conference on Electrical Engineering (ICEE).

[4]  J.R. Jones,et al.  Computer algorithm for selection of frequency relays for load shedding , 1988, IEEE Computer Applications in Power.

[5]  H. H. Happ,et al.  Power System Control and Stability , 1979, IEEE Transactions on Systems, Man, and Cybernetics.

[6]  Deqiang Gan,et al.  An investigation into WAMS-based Under-frequency load shedding , 2012, PES 2012.

[7]  Hemanshu R. Pota,et al.  Islanding Detection of Synchronous Distributed Generator Based on the Active and Reactive Power Control Loops , 2018, Energies.

[8]  George Cristian Lazaroiu,et al.  Power Quality of Electrical Power Systems , 2019 .

[9]  Hassan Haes Alhelou Under Frequency Load Shedding Techniques for Future Smart Power Systems , 2019, Handbook of Research on Smart Power System Operation and Control.

[10]  Shan Gao,et al.  Security-Based Active Demand Response Strategy Considering Uncertainties in Power Systems , 2017, IEEE Access.

[11]  U Rudez,et al.  Monitoring the First Frequency Derivative to Improve Adaptive Underfrequency Load-Shedding Schemes , 2011, IEEE Transactions on Power Systems.

[12]  Masoud Hajiakbari Fini,et al.  Multi agent electric vehicle control based primary frequency support for future smart micro-grid , 2015, 2015 Smart Grid Conference (SGC).

[13]  Hassan Haes Alhelou,et al.  Wind Driven Optimization Algorithm Application to Load Frequency Control in Interconnected Power Systems Considering GRC and GDB Nonlinearities , 2018 .

[14]  Fangxing Li,et al.  Analytical Method to Aggregate Multi-Machine SFR Model With Applications in Power System Dynamic Studies , 2018, IEEE Transactions on Power Systems.

[15]  Fang Liu,et al.  A Two-Layer Active Disturbance Rejection Controller Design for Load Frequency Control of Interconnected Power System , 2016, IEEE Transactions on Power Systems.

[16]  Hassan Haes Alhelou An Overview of Wide Area Measurement System and Its Application in Modern Power Systems , 2019 .

[17]  Le-Ren Chang-Chien,et al.  Incorporating Demand Response With Spinning Reserve to Realize an Adaptive Frequency Restoration Plan for System Contingencies , 2012, IEEE Transactions on Smart Grid.

[18]  I. Kamwa,et al.  PMU Configuration for System Dynamic Performance Measurement in Large Multiarea Power Systems , 2002, IEEE Power Engineering Review.

[19]  J. A. Laghari,et al.  Application of computational intelligence techniques for load shedding in power systems: A review , 2013 .

[20]  Hassan Haes Alhelou Fault Detection and Isolation in Power Systems Using Unknown Input Observer , 2019 .

[21]  W.A. Mittelstadt,et al.  Use of the WECC WAMS in Wide-Area Probing Tests for Validation of System Performance and Modeling , 2009, IEEE Transactions on Power Systems.

[22]  Morteza Sarailoo,et al.  Cost-Effective Upgrade of PMU Networks for Fault-Tolerant Sensing , 2018, IEEE Transactions on Power Systems.

[23]  K. R. Padiyar,et al.  Power system dynamics : stability and control , 1996 .

[24]  A.G. Phadke,et al.  Power system frequency monitoring network (FNET) implementation , 2005, IEEE Transactions on Power Systems.

[25]  Hazlie Mokhlis,et al.  Improved UFLS with Consideration of Power Deficit During Shedding Process And Flexible Load Selection , 2018 .

[26]  Hassan Haes Alhelou,et al.  Robust sensor fault detection and isolation scheme for interconnected smart power systems in presence of RER and EVs using unknown input observer , 2018, International Journal of Electrical Power & Energy Systems.

[27]  Yan Xu,et al.  A Robust Load Frequency Control Scheme for Power Systems Based on Second-Order Sliding Mode and Extended Disturbance Observer , 2018, IEEE Transactions on Industrial Informatics.

[28]  Nand Kishor,et al.  Distributed Multi-Agent System-Based Load Frequency Control for Multi-Area Power System in Smart Grid , 2017, IEEE Transactions on Industrial Electronics.

[29]  Hassan Haes Alhelou,et al.  Comparative study on the performance of many-objective and single-objective optimisation algorithms in tuning load frequency controllers of multi-area power systems , 2016 .

[30]  A. Grobovoy,et al.  Development of applications in WAMS and WACS: an international cooperation experience , 2006, 2006 IEEE Power Engineering Society General Meeting.

[31]  Stelios Timotheou,et al.  Minimal Load Shedding Using the Swing Equation , 2017, IEEE Transactions on Power Systems.

[32]  V. Terzija,et al.  Adaptive underfrequency load shedding based on the magnitude of the disturbance estimation , 2006, IEEE Transactions on Power Systems.

[33]  Abbas Ketabi,et al.  An Underfrequency Load Shedding Scheme for Hybrid and Multiarea Power Systems , 2015, IEEE Transactions on Smart Grid.

[34]  C. C. Wu,et al.  Frequency-based method for fast-response reserve dispatch in isolated power systems , 2004 .

[35]  Vahid Madani,et al.  Wide-Area Monitoring, Protection, and Control of Future Electric Power Networks , 2011, Proceedings of the IEEE.

[36]  Denis Lee Hau Aik A general-order system frequency response model incorporating load shedding: analytic modeling and applications , 2006, IEEE Transactions on Power Systems.

[37]  Pierluigi Siano,et al.  Challenges and Opportunities of Load Frequency Control in Conventional, Modern and Future Smart Power Systems: A Comprehensive Review , 2018, Energies.