Validation of a digital PCR method for quantification of DNA copy number concentrations by using a certified reference material

Digital PCR has become the emerging technique for the sequence-specific detection and quantification of nucleic acids for various applications. During the past years, numerous reports on the development of new digital PCR methods have been published. Maturation of these developments into reliable analytical methods suitable for diagnostic or other routine testing purposes requires their validation for the intended use. Here, the results of an in-house validation of a droplet digital PCR method are presented. This method is intended for the quantification of the absolute copy number concentration of a purified linearized plasmid in solution with a nucleic acid background. It has been investigated which factors within the measurement process have a significant effect on the measurement results, and the contribution to the overall measurement uncertainty has been estimated. A comprehensive overview is provided on all the aspects that should be investigated when performing an in-house method validation of a digital PCR method.

[1]  H Emons,et al.  A certified plasmid reference material for the standardisation of BCR–ABL1 mRNA quantification by real-time quantitative PCR , 2014, Leukemia.

[2]  S. Primrose,et al.  Measurement issues associated with quantitative molecular biology analysis of complex food matrices for the detection of food fraud. , 2016, The Analyst.

[3]  Philippe Corbisier,et al.  Single molecule detection in nanofluidic digital array enables accurate measurement of DNA copy number , 2009, Analytical and bioanalytical chemistry.

[4]  K. Jerome,et al.  The potential advantages of digital PCR for clinical virology diagnostics , 2014, Expert review of molecular diagnostics.

[5]  John Frater,et al.  Low copy target detection by Droplet Digital PCR through application of a novel open access bioinformatic pipeline, ‘definetherain’ , 2014, Journal of virological methods.

[6]  A V Emanuel',et al.  [The practice of development and implementation of quality management systems in medical laboratories. The GOST R ISO 15189-2009 "medical laboratories. The detailed requirements to quality and competence". Particular difficulties of global nature]. , 2012, Klinicheskaia laboratornaia diagnostika.

[7]  M. Maher,et al.  GUIDELINES ON PERFORMANCE CRITERIA AND VALIDATION OF METHODS FOR DETECTION, IDENTIFICATION AND QUANTIFICATION OF SPECIFIC DNA SEQUENCES AND SPECIFIC PROTEINS IN FOODS , 2010 .

[8]  Paul H Dear,et al.  Digital PCR strategies in the development and analysis of molecular biomarkers for personalized medicine. , 2013, Methods.

[9]  Christopher M. Hindson,et al.  Absolute quantification by droplet digital PCR versus analog real-time PCR , 2013, Nature Methods.

[10]  J. Kramar,et al.  Method for Measuring the Volume of Nominally 100 um Diameter Spherical Water-in-Oil Emulsion Droplets , 2016 .

[11]  Corbisier Philippe,et al.  CERTIFICATION REPORT: The certification of the mass of lambda DNA in a solution Certified Reference Material: ERM®-AD442k , 2015 .

[12]  P. Corbisier,et al.  Oligonucleotide batch quality has a limited impact on quantitative real-time PCR , 2012, European Food Research and Technology.

[13]  Carole A. Foy,et al.  Considerations for accurate gene expression measurement by reverse transcription quantitative PCR when analysing clinical samples , 2014, Analytical and Bioanalytical Chemistry.

[14]  Jeff Mellen,et al.  High-Throughput Droplet Digital PCR System for Absolute Quantitation of DNA Copy Number , 2011, Analytical chemistry.

[15]  Tania Nolan,et al.  The digital MIQE guidelines: Minimum Information for Publication of Quantitative Digital PCR Experiments. , 2013, Clinical chemistry.

[16]  Ugo Pastorino,et al.  Novel method to detect microRNAs using chip-based QuantStudio 3D digital PCR , 2015, BMC Genomics.

[17]  Ie-Ming Shih,et al.  Principle and applications of digital PCR , 2004, Expert review of molecular diagnostics.

[18]  Ramesh Ramakrishnan,et al.  Mathematical Analysis of Copy Number Variation in a DNA Sample Using Digital PCR on a Nanofluidic Device , 2008, PloS one.

[19]  F. Watzinger,et al.  Evaluation of candidate control genes for diagnosis and residual disease detection in leukemic patients using ‘real-time’ quantitative reverse-transcriptase polymerase chain reaction (RQ-PCR) – a Europe against cancer program , 2003, Leukemia.

[20]  H. Cavé,et al.  Standardization and quality control studies of ‘real-time’ quantitative reverse transcriptase polymerase chain reaction of fusion gene transcripts for residual disease detection in leukemia – A Europe Against Cancer Program , 2003, Leukemia.

[21]  Jung-Keun Lee,et al.  EURACHEM/CITAC Guide: Quantifying Uncertainty in Analytical Measurement, Ellison, S.L.R., Rosslein, M., and Williams, A., Eds., 2nd ed.; translated under the title Rukovodstvo EVRAKhIM/SITAK: Kolichestvennoe opisanie neopredelennosti v analiticheskikh izmereniyakh, Konopel'ko, L.A., Ed., St. Petersb , 2003 .

[22]  Michael Thompson,et al.  Harmonized guidelines for single-laboratory validation of methods of analysis (IUPAC Technical Report) , 2002 .

[23]  Leonard Steinborn,et al.  International Organization for Standardization ISO/IEC 17025 General Requirements for the Competence of Testing and Calibration Laboratories , 2004 .

[24]  Richard C. Friedberg,et al.  International Organization for Standardization (ISO) 15189 , 2017, Annals of laboratory medicine.

[25]  Jim F Huggett,et al.  Considerations for digital PCR as an accurate molecular diagnostic tool. , 2015, Clinical chemistry.

[26]  Hendrik Emons,et al.  DNA copy number concentration measured by digital and droplet digital quantitative PCR using certified reference materials , 2015, Analytical and Bioanalytical Chemistry.

[27]  K. Kinzler,et al.  Digital PCR. , 1999, Proceedings of the National Academy of Sciences of the United States of America.

[28]  T. Dingle,et al.  Tolerance of droplet-digital PCR vs real-time quantitative PCR to inhibitory substances. , 2013, Clinical chemistry.

[29]  Jing Wang,et al.  Comparison of four digital PCR platforms for accurate quantification of DNA copy number of a certified plasmid DNA reference material , 2015, Scientific Reports.

[30]  宁北芳,et al.  疟原虫var基因转换速率变化导致抗原变异[英]/Paul H, Robert P, Christodoulou Z, et al//Proc Natl Acad Sci U S A , 2005 .

[31]  Qun Zhong,et al.  Multiplex digital PCR: breaking the one target per color barrier of quantitative PCR. , 2011, Lab on a chip.

[32]  Kerry R Emslie,et al.  Comparison of methods for accurate quantification of DNA mass concentration with traceability to the international system of units. , 2010, Analytical chemistry.