Why fat is bright in rare and fast spin‐echo imaging

Fast spin‐echo (FSE) sequences are becoming popular for T2‐weighted clinical imaging because they result in a severalfold reduction in imaging time and because they provide conventional spin‐echo contrast for most tissues. Fat, however, has been observed to have anomalously high signal intensity on FSE images. The present study shows that the brighter fat results from the multiple 180° refocusing pulses, which eliminate diffusion‐mediated susceptibility dephasing and suppress J‐coupling modulation of the echo train.

[1]  J C Gore,et al.  Factors influencing contrast in fast spin-echo MR imaging. , 1992, Magnetic resonance imaging.

[2]  R. Freeman,et al.  5 – Determination of Spin–Spin Relaxation Times in High-Resolution NMR , 1975 .

[3]  C. S. Poon,et al.  Practical T2 quantitation for clinical applications , 1992, Journal of magnetic resonance imaging : JMRI.

[4]  R. Vold,et al.  Transverse relaxation in heteronuclear coupled spin systems: AX, AX2, AX3, and AXY , 1976 .

[5]  F A Jolesz,et al.  Phase-encode order and its effect on contrast and artifact in single-shot RARE sequences. , 1991, Medical physics.

[6]  R. S. Hinks,et al.  Problems with organic materials for magnetic resonance imaging phantoms. , 1988, Medical Physics (Lancaster).

[7]  J C Gore,et al.  Effects of selective pulses on the measurement of T2 and apparent diffusion in multiecho MRI , 1987, Magnetic resonance in medicine.

[8]  T. Tokuhiro,et al.  Modulation of Spin Echoes in Multi‐Half‐Spin Systems. I. Closed Formulas of Carr–Purcell Spin Echoes in Several AaBXx Systems , 1968 .

[9]  H. Carr,et al.  The Principles of Nuclear Magnetism , 1961 .

[10]  D. Twieg The k-trajectory formulation of the NMR imaging process with applications in analysis and synthesis of imaging methods. , 1983, Medical physics.

[11]  R M Henkelman,et al.  On the Transverse relaxation rate enhancement induced by diffusion of spins through inhomogeneous fields , 1991, Magnetic resonance in medicine.

[12]  A. Allerhand Modulation of Carr–Purcell Spin‐Echo Trains in Homonuclear AaBXx Systems , 1969 .

[13]  J Hennig,et al.  Rapid nontomographic approach to MR myelography without contrast agents. , 1986, Journal of computer assisted tomography.

[14]  J. Hennig Multiecho imaging sequences with low refocusing flip angles , 1988 .

[15]  A. Allerhand Analysis of Carr—Purcell Spin‐Echo NMR Experiments on Multiple‐Spin Systems. I. The Effect of Homonuclear Coupling , 1966 .

[16]  J. E. Tanner,et al.  Spin diffusion measurements : spin echoes in the presence of a time-dependent field gradient , 1965 .

[17]  C. S. Poon,et al.  180° refocusing pulses which are insensitive to static and radiofrequency field inhomogeneity , 1992 .

[18]  J Hennig,et al.  Clinical applications and methodological developments of the RARE technique. , 1988, Magnetic resonance imaging.

[19]  Y. Mauss,et al.  Effect of interpulse delay on NMR transverse relaxation rate of tissues , 1986 .

[20]  M. Bronskill,et al.  Variation in measured transverse relaxation in tissue resulting from spin locking with the CPMG sequence , 1988 .

[21]  L P Panych,et al.  Comparing the FAISE method with conventional dual‐echo sequences , 1991, Journal of magnetic resonance imaging : JMRI.

[22]  Paul A. Bottomley,et al.  19F magnetic resonance imaging , 1977 .

[23]  A. Crawley,et al.  Errors in T2 estimation using multislice multiple‐echo imaging , 1987, Magnetic resonance in medicine.