A constrained least‐squares approach to the automated quantitation of in vivo 1H magnetic resonance spectroscopy data

Totally Automatic Robust Quantitation in NMR (TARQUIN), a new method for the fully automatic analysis of short echo time in vivo 1H Magnetic resonance spectroscopy is presented. Analysis is performed in the time domain using non‐negative least squares, and a new method for applying soft constraints to signal amplitudes is used to improve fitting stability. Initial point truncation and Hankel singular value decomposition water removal are used to reduce baseline interference. Three methods were used to test performance. First, metabolite concentrations from six healthy volunteers at 3 T were compared with LCModel™. Second, a Monte‐Carlo simulation was performed and results were compared with LCModel™ to test the accuracy of the new method. Finally, the new algorithm was applied to 1956 spectra, acquired clinically at 1.5 T, to test robustness to noisy, abnormal, artifactual, and poorly shimmed spectra. Discrepancies of less than approximately 20% were found between the main metabolite concentrations determined by TARQUIN and LCModel™ from healthy volunteer data. The Monte‐Carlo simulation revealed that errors in metabolite concentration estimates were comparable with LCModel™. TARQUIN analyses were also found to be robust to clinical data of variable quality. In conclusion, TARQUIN has been shown to be an accurate and robust algorithm for the analysis of magnetic resonance spectroscopy data making it suitable for use in a clinical setting. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.

[1]  Theodoros N. Arvanitis,et al.  A comparison between simulated and experimental basis sets for assessing short‐TE in vivo 1H MRS data at 1.5 T , 2010, NMR in biomedicine.

[2]  B. Barbiroli,et al.  Pitfalls and advantages of different strategies for the absolute quantification of N‐acetyl aspartate, creatine and choline in white and grey matter by 1H‐MRS , 2009, NMR in biomedicine.

[3]  D. van Ormondt,et al.  Reliability testing of in vivo magnetic resonance spectroscopy (MRS) signals and signal artifact reduction by order statistic filtering , 2009 .

[4]  Rolf Gruetter,et al.  MR spectroscopy of the human brain with enhanced signal intensity at ultrashort echo times on a clinical platform at 3T and 7T , 2009, Magnetic resonance in medicine.

[5]  S. Van Huffel,et al.  MRS signal quantitation: a review of time- and frequency-domain methods. , 2008, Journal of magnetic resonance.

[6]  Carles Arús,et al.  Automated quality control protocol for MR spectra of brain tumors , 2008, Magnetic resonance in medicine.

[7]  Laurent Lamalle,et al.  Short‐TE localised 1H MRS of the human brain at 3 T: quantification of the metabolite signals using two approaches to account for macromolecular signal contributions , 2008, NMR in biomedicine.

[8]  David Bonekamp,et al.  Regional apparent metabolite concentrations in young adult brain measured by 1H MR spectroscopy at 3 Tesla , 2008, Journal of magnetic resonance imaging : JMRI.

[9]  Sabine Van Huffel,et al.  An automated quantitation of short echo time MRS spectra in an open source software environment: AQSES , 2007, NMR in biomedicine.

[10]  S. Huffel,et al.  Separable nonlinear least squares fitting with linear bound constraints and its application in magnetic resonance spectroscopy data quantification , 2007 .

[11]  Theodoros N. Arvanitis,et al.  An algorithm for the automated quantitation of metabolites in in vitro NMR signals , 2006, Magnetic resonance in medicine.

[12]  Peter Boesiger,et al.  ProFit: two‐dimensional prior‐knowledge fitting of J‐resolved spectra , 2006, NMR in biomedicine.

[13]  M. Fukushima,et al.  Erratum to Levenberg-Marquardt methods with strong local convergence properties for solving nonlinear equations with convex constraints , 2005 .

[14]  M. Sdika,et al.  Time‐domain semi‐parametric estimation based on a metabolite basis set , 2005, NMR in biomedicine.

[15]  L. Astrakas,et al.  Noninvasive Magnetic Resonance Spectroscopic Imaging Biomarkers to Predict the Clinical Grade of Pediatric Brain Tumors , 2004, Clinical Cancer Research.

[16]  R. Kreis Issues of spectral quality in clinical 1H‐magnetic resonance spectroscopy and a gallery of artifacts , 2004, NMR in biomedicine.

[17]  Johannes Bernarding,et al.  Quantitation of simulated short echo time 1H human brain spectra by LCModel and AMARES , 2004, Magnetic resonance in medicine.

[18]  P. Gemperline,et al.  Advantages of soft versus hard constraints in self-modeling curve resolution problems. Alternating least squares with penalty functions. , 2003, Analytical chemistry.

[19]  Wolfgang Grodd,et al.  Parameterized evaluation of macromolecules and lipids in proton MR spectroscopy of brain diseases , 2003, Magnetic resonance in medicine.

[20]  D. Graveron-Demilly,et al.  Java-based graphical user interface for the MRUI quantitation package , 2001, Magnetic Resonance Materials in Physics, Biology and Medicine.

[21]  R. Kauppinen,et al.  1H NMR visible lipids in the life and death of cells. , 2000, Trends in biochemical sciences.

[22]  V. Govindaraju,et al.  Proton NMR chemical shifts and coupling constants for brain metabolites , 2000, NMR in biomedicine.

[23]  S. Williams,et al.  In vivo NMR spectroscopy: Principles and techniques, R.A. de Graaf, Wiley, Chichester, 1998, Hardback £120 ISBN 0-471-98365-9 , 1999 .

[24]  de Beer R,et al.  LeuvenDepartement Elektrotechniek ESAT-SISTA / TR 1997-89 Fast removal of residual water in proton spectra 1 , 2022 .

[25]  Vanhamme,et al.  Improved method for accurate and efficient quantification of MRS data with use of prior knowledge , 1997, Journal of magnetic resonance.

[26]  J Higinbotham,et al.  Use of voigt lineshape for quantification of in vivo 1H spectra , 1997, Magnetic resonance in medicine.

[27]  D. Louis Collins,et al.  Accurate, noninvasive diagnosis of human brain tumors by using proton magnetic resonance spectroscopy , 1996, Nature Medicine.

[28]  K. Behar,et al.  Analysis of macromolecule resonances in 1H NMR spectra of human brain , 1994, Magnetic resonance in medicine.

[29]  S. Provencher Estimation of metabolite concentrations from localized in vivo proton NMR spectra , 1993, Magnetic resonance in medicine.

[30]  B D Ross,et al.  Absolute Quantitation of Water and Metabolites in the Human Brain. I. Compartments and Water , 1993 .

[31]  A. D. de Graaf,et al.  Quality: quantification improvement by converting lineshapes to the lorentzian type , 1990, Magnetic resonance in medicine.

[32]  Ad Bax,et al.  Improved solvent suppression in one-and two-dimensional NMR spectra by convolution of time-domain data , 1989 .

[33]  Jack H. Freed,et al.  Rapid singular value decomposition for time-domain analysis of magnetic resonance signals by use of the lanczos algorithm , 1989 .

[34]  P. Luyten,et al.  Accurate quantification of in vivo 31P NMR signals using the variable projection method and prior knowledge , 1988, Magnetic resonance in medicine.

[35]  D. van Ormondt,et al.  Improved algorithm for noniterative time-domain model fitting to exponentially damped magnetic resonance signals , 1987 .

[36]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[37]  D. van Ormondt,et al.  Retrieval of frequencies, amplitudes, damping factors, and phases from time-domain signals using a linear least-squares procedure , 1985 .

[38]  Charles L. Lawson,et al.  Solving least squares problems , 1976, Classics in applied mathematics.

[39]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[40]  C. Kanzow Levenberg-Marquardt methods for constrained nonlinear equations with strong local convergence properties , 2004 .

[41]  M. Levitt Spin Dynamics: Basics of Nuclear Magnetic Resonance , 2001 .

[42]  B. Meier,et al.  Computer Simulations in Magnetic Resonance. An Object-Oriented Programming Approach , 1994 .

[43]  S. Schelling,et al.  Pediatric neuroimaging. , 1994, Seminars in veterinary medicine and surgery.