Analysis of lead oxide (PbO) layers for direct conversion X-ray detection

Lead oxide (PbO) is a candidate direct conversion material for medical X-ray applications. We produced various samples and detectors with thick PbO layers. X-ray performance data such as dark current, charge generation yield and temporal behavior were evaluated on small samples. The influence of the metal contacts was studied in detail. We also covered large a-Si thin-film transistor (TFT)-plates with PbO. Imaging results from a large detector with an active area of 18 cm /spl times/ 20 cm are presented. The detector has 960 /spl times/ 1080 pixels with a pixel pitch of 184 /spl mu/m. The modulation transfer function at the Nyquist frequency of 2.72 linepairs/mm is 50%. Finally, a full size X-ray image is presented.

[1]  Torsten Solf,et al.  Temporal artifacts in flat dynamic x-ray detectors , 2001, SPIE Medical Imaging.

[2]  Kunio Doi,et al.  A simple method for determining the modulation transfer function in digital radiography , 1992, IEEE Trans. Medical Imaging.

[3]  K Stierstorfer,et al.  Self-normalizing method to measure the detective quantum efficiency of a wide range of x-ray detectors. , 1999, Medical physics.

[4]  Falko Busse,et al.  Methodology to measure fundamental performance parameters of x-ray detectors , 2001, SPIE Medical Imaging.

[5]  Larry Partain,et al.  Mercuric iodide medical imagers for low-exposure radiography and fluoroscopy , 2004, SPIE Medical Imaging.

[6]  K. Hecht Zum Mechanismus des lichtelektrischen Primärstromes in isolierenden Kristallen , 1932 .

[7]  Safa Kasap,et al.  Direct-conversion flat-panel X-ray image sensors for digital radiography , 2002, Proceedings of the IEEE.

[8]  Douglas Albagli,et al.  Performance of a flat-panel cardiac detector , 2001, SPIE Medical Imaging.

[9]  John A. Rowlands,et al.  Investigation of lag and ghosting in amorphous selenium flat-panel x-ray detectors , 2002, SPIE Medical Imaging.

[10]  Martin J Yaffe,et al.  Direct conversion detectors: the effect of incomplete charge collection on detective quantum efficiency. , 2002, Medical physics.

[11]  Falko Busse,et al.  Design and performance of a high-quality cardiac flat detector , 2002, SPIE Medical Imaging.

[12]  Matthias Simon,et al.  PbO as direct conversion x-ray detector material , 2004, SPIE Medical Imaging.

[13]  J A Rowlands,et al.  Evaluation of the imaging properties of an amorphous selenium-based flat panel detector for digital fluoroscopy. , 2004, Medical physics.

[14]  Norbert Conrads,et al.  X-Ray Sensing Properties of a Lead Oxide Photoconductor Combined With an Amorphous Silicon Tft Array , 1998 .

[15]  Susumu Adachi,et al.  Improvement of temporal response and output uniformity of polycrystalline CdZnTe films for high-sensitivity x-ray imaging , 2003, SPIE Medical Imaging.

[16]  D. Wiechert,et al.  Raman spectroscopic investigation of evaporated PbO layers , 2005 .

[17]  Kanai S. Shah,et al.  Improved properties of PbI2 x-ray imagers with tighter process control and using positive bias voltage , 2004, SPIE Medical Imaging.