Focalizing electrical neural stimulation with penetrating microelectrode arrays: A modeling study

Penetrating neural probes are considered for neuroprosthetic devices to restore sensory or motor functions of the CNS using electrical neural microstimulation. These multielectrode systems require optimal electrode configurations to allow precise and focused tissue activation. Combining a finite element model of the spinal cord and compartmentalized models of both simple and complex neuron morphologies, we evaluated the use of the "ground surface" configuration, which consists in the integration of a conductive layer on the front side of electrode shanks, for the return of the stimulation current. Compared to the classical monopolar and bipolar configurations, this strategy resulted in a focalization of both the potential field and the threshold-distance curves. The improvement in focalization was highest for lowest impedance of the ground surface. Moreover, the gain in focality was highest on the side of the shank opposite to the electrode, so that only the neurons located in front of stimulation electrode were activated. This focalizing strategy will allow the design of new microstimulation paradigms aiming at precisely targeting the CNS with complex spatio-temporal stimulation patterns, which could benefit to future stimulation-based neuroprosthesis.

[1]  David J. Anderson,et al.  Penetrating multichannel stimulation and recording electrodes in auditory prosthesis research , 2008, Hearing Research.

[2]  D J Weber,et al.  Microstimulation of primary afferent neurons in the L7 dorsal root ganglia using multielectrode arrays in anesthetized cats: thresholds and recruitment properties , 2009, Journal of neural engineering.

[3]  J. Rizzo,et al.  Multi-electrode stimulation and recording in the isolated retina , 2000, Journal of Neuroscience Methods.

[4]  P Bergonzo,et al.  Three-dimensional electrode arrays for retinal prostheses: modeling, geometry optimization and experimental validation , 2011, Journal of neural engineering.

[5]  Blaise Yvert,et al.  Nanostructuration strategies to enhance microelectrode array (MEA) performance for neuronal recording and stimulation , 2012, Journal of Physiology-Paris.

[6]  Karel Vytras,et al.  Combined macro-/mesoporous microelectrode arrays for low-noise extracellular recording of neural networks. , 2012, Journal of neurophysiology.

[7]  Richard A Normann,et al.  Technology Insight: future neuroprosthetic therapies for disorders of the nervous system , 2007, Nature Clinical Practice Neurology.

[8]  Daryl R Kipke,et al.  Development of Closed-Loop Neural Interface Technology in a Rat Model: Combining Motor Cortex Operant Conditioning With Visual Cortex Microstimulation , 2010, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[9]  Nicholas G Hatsopoulos,et al.  The science of neural interface systems. , 2009, Annual review of neuroscience.

[10]  J M Carmena,et al.  In Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording , 2011, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[11]  Nicholas T. Carnevale,et al.  The NEURON Simulation Environment , 1997, Neural Computation.

[12]  Niranjan Kambi,et al.  Reorganization of the Primary Motor Cortex of Adult Macaque Monkeys after Sensory Loss Resulting from Partial Spinal Cord Injuries , 2011, The Journal of Neuroscience.

[13]  Jose M. Carmena,et al.  Frontiers in Integrative Neuroscience Integrative Neuroscience Behavioral Modulation of Stimulus-evoked Oscillations in Barrel Cortex of Alert Rats Materials and Methods , 2022 .

[14]  Philippe Renaud,et al.  Simulation of epiretinal prostheses - Evaluation of geometrical factors affecting stimulation thresholds , 2011, Journal of NeuroEngineering and Rehabilitation.

[15]  Sébastien Joucla,et al.  Improved Focalization of Electrical Microstimulation Using Microelectrode Arrays: A Modeling Study , 2009, PloS one.

[16]  J. Holsheimer,et al.  Excitation of dorsal root fibers in spinal cord stimulation: a theoretical study , 1993, IEEE Transactions on Biomedical Engineering.

[17]  T. Sejnowski,et al.  [Letters to nature] , 1996, Nature.

[18]  Sébastien Joucla,et al.  Modeling extracellular electrical neural stimulation: From basic understanding to MEA-based applications , 2012, Journal of Physiology-Paris.