Using statistical deformation models for the registration of multimodal breast images
暂无分享,去创建一个
This paper describes a novel method for registering multimodal breast images. The method is based on guiding initial alignment by a 3D statistical deformation model (SDM) followed by a standard non-rigid registration method for fine alignment. The method was applied to the problem of compensating for large breast compressions, namely registering magnetic resonance (MR) images to tomosynthesis images and X-ray mammograms. The SDM was based on simulating plausible breast compressions for a population of 20 subjects via finite element models created from segmented 3D MR breast images. Leave-one-out tests on simulated data showed that using SDM guided registration rather than affine registration for the initial alignment led on average to lower mean registration errors, namely 3.2 mm versus 4.2 mm for MR to tomosynthesis images (17.1 mm initially) and 5.0 mm versus 6.2 mm for MR to X-ray mammograms (15.0 mm initially).