Influence Mechanism from the Inner Walkway on the Performance of an Air-Cooled Power Plant

AbstractIn view of the sensitivity to the wind conditions, the architecture of the air-cooled steam condenser (ACSC) always affects the characteristics of the whole power plant. As a result, it is important to structure a reasonable ACSC for better comprehensive performance in the power plant. This paper uses an existing numerical model to discuss the impact mechanisms from the inner walkway on the performance of the ACSC, and the relevant characteristics of the power plant at different inner walkways is also studied. It is found that the performance of the ACSC as well as the power plant is improved by extending the length extending of the inner walkway, thus shrinking the negative pressure regions around the fan surfaces. Finally, the net power and the thermal efficiency are improved by an amplitude of 1.2 and 0.3% from Lw=0 to 2 m, respectively, for the inner walkway based on the relevant value at the design wind speed case. It is concluded that an appropriate inner walkway should be chosen during the ...

[1]  He Weifeng,et al.  Mechanism of the air temperature rise at the forced draught fan inlets in an air-cooled steam condenser , 2014 .

[2]  Xiaoze Du,et al.  Influences of wind-break wall configurations upon flow and heat transfer characteristics of air-cooled condensers in a power plant , 2011 .

[3]  Yan Li,et al.  Wind tunnel simulation of exhaust recirculation in an air-cooling system at a large power plant , 2007 .

[4]  Michael Owen A numerical investigation of air-cooled steam condenser performance under windy conditions , 2010 .

[5]  Maoqing Li,et al.  Performance prediction of an air-cooled steam condenser using UDF method , 2013 .

[6]  He Weifeng,et al.  Influence from the rotating speed of the windward axial fans on the performance of an air-cooled power plant , 2014 .

[7]  Qiuwang Wang,et al.  Effect of building re-entrant shape on performance of air-cooled condensing units , 2000 .

[8]  Xiaoze Du,et al.  POD based modeling on flow and heat transfer of air-cooled condenser influenced by natural wind , 2014 .

[9]  C. J. Meyer Numerical investigation of the effect of inlet flow distortions on forced draught air-cooled heat exchanger performance , 2005 .

[10]  Xiaoze Du,et al.  Space characteristics of the thermal performance for air-cooled condensers at ambient winds , 2011 .

[11]  Bo Yu,et al.  Numerical simulation of heat transfer performance of an air-cooled steam condenser in a thermal power plant , 2009 .

[12]  Detlev G. Kröger,et al.  Performance Trends of an Air-Cooled Steam Condenser Under Windy Conditions , 2008 .