Finite Element Study on the Amount of Injection Cement During the Pedicle Screw Augmentation

Study Design: A finite element analysis of the screw pullout procedure for the osteoporotic cancellous bone using screw-bone unit model without cortical layer. Objective: The objective is to determine the region of effect (RoE) during the screw pullout procedure and predict the proper amount of injection cement (AIC) in screw augmentation. Summary of Background Data: For the osteoporotic spine, the AIC is a critical factor for the augmentation screw performance and leakage risk. There are few studies on the proper AIC in literature. Methods: Three finite element models were established, 2 screw-foam models were used for validation study, and 1 screw-bone model was used for investigation of RoE and AIC. The simulations of screw pullout were conducted. A velocity loading of 0.01 mm/s with a maximum displacement of 2.7 mm was applied on the screw. For the validation, the screw-foam models with 2 different densities were used for comparison of pullout force with those published experimental data. After validation, the screw-bone model was used to investigate the RoE and predict the proper AIC during screw augmentation in spine surgery. Results: In validation, the predicted pullout strengths were 2028.8 N for high-density foam model and 607 N for low-density foam model, respectively. They were in good agreement with those of the published experiment. In the screw-bone model, the simulations demonstrated that the RoE changed with the displacement of screw and reached the maximum when the displacement of screw was 1.8 mm. Similar trend was found for the AIC with the displacement. The proper AIC was 2.6 mL when the displacement of screw was 1.8 mm in this study. Conclusions: The RoE and proper AIC for augmentation were evaluated in the osteoporotic spine. This information could provide practical reference for screw augmentation in spinal decompression and instrumentation in the spine surgery.

[1]  Zi-xiang Wu,et al.  Biomechanical evaluation of fixation strength of conventional and expansive pedicle screws with or without calcium based cement augmentation. , 2011, Clinical biomechanics.

[2]  J. P. Little,et al.  Development of a multi-scale finite element model of the osteoporotic lumbar vertebral body for the investigation of apparent level vertebra mechanics and micro-level trabecular mechanics. , 2010, Medical engineering & physics.

[3]  N. Verdonschot,et al.  Fatigue creep damage at the cement-bone interface: an experimental and a micro-mechanical finite element study. , 2009, Journal of biomechanics.

[4]  J. Wulf,et al.  Temperature elevation during simulated polymethylmethacrylate (PMMA) cranioplasty in a cadaver model , 2010, Journal of Clinical Neuroscience.

[5]  S. Chueh,et al.  Failure analysis of broken pedicle screws on spinal instrumentation. , 2005, Medical engineering & physics.

[6]  M Y He,et al.  Mechanisms governing the inelastic deformation of cortical bone and application to trabecular bone. , 2006, Acta biomaterialia.

[7]  L. Gibson Biomechanics of cellular solids. , 2005, Journal of biomechanics.

[8]  M. Sabbaghian,et al.  Load Distribution Between Threads in Threaded Connections , 1997 .

[9]  D. Bednar,et al.  Pullout strength of pedicle screws augmented with particulate calcium phosphate: an experimental study. , 2009, The spine journal : official journal of the North American Spine Society.

[10]  Zi-xiang Wu,et al.  Effect of ovariectomy on BMD, micro-architecture and biomechanics of cortical and cancellous bones in a sheep model. , 2008, Medical engineering & physics.

[11]  Qing Hang Zhang,et al.  Effects of bone materials on the screw pull-out strength in human spine. , 2006, Medical engineering & physics.

[12]  G. Niebur,et al.  Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue. , 2004, Journal of biomechanics.

[13]  Masato Tanaka,et al.  Clinical application of a pedicle nail system with polymethylmethacrylate for osteoporotic vertebral fracture , 2010, European Spine Journal.

[14]  E. Teo,et al.  Relationship between architectural parameters and sample volume of human cancellous bone in micro-CT scanning. , 2011, Medical engineering & physics.

[15]  R. T. Allen,et al.  Spine surgeons survey on attitudes regarding osteoporosis and osteomalacia screening and treatment for fractures, fusion surgery, and pseudoarthrosis. , 2009, The spine journal : official journal of the North American Spine Society.

[16]  T. Washio,et al.  An Experimental Study of a Combination Method Using a Pedicle Screw and Laminar Hook for the Osteoporotic Spine , 1997, Spine.

[17]  D. Shin,et al.  Serious Complication of Cement Augmentation for Damaged Pilot Hole , 2010, Yonsei medical journal.

[18]  W. D. Dover,et al.  Stress analysis of drillstring threaded connections using the finite element method , 1993 .

[19]  Douglas L Burton,et al.  Cement Augmentation of Pedicle Screw Fixation Using Novel Cannulated Cement Insertion Device , 2009, Spine.

[20]  N. Altinors,et al.  Augmentation of a Loosened Sacral Pedicle Screw With Percutaneous Polymethylmethacrylate Injection , 2006, Journal of spinal disorders & techniques.

[21]  Stavros K Kourkoulis,et al.  A parametric study of cylindrical pedicle screw design implications on the pullout performance using an experimentally validated finite-element model. , 2010, Medical engineering & physics.

[22]  R. McLain,et al.  Primary Pedicle Screw Augmentation in Osteoporotic Lumbar Vertebrae: Biomechanical Analysis of Pedicle Fixation Strength , 2007, Spine.

[23]  Nico Verdonschot,et al.  Micro-mechanical modeling of the cement-bone interface: the effect of friction, morphology and material properties on the micromechanical response. , 2008, Journal of biomechanics.

[24]  W C Hayes,et al.  Postyield behavior of subchondral trabecular bone. , 1976, Journal of biomedical materials research.

[25]  T. Keaveny,et al.  Trabecular bone strength predictions using finite element analysis of micro-scale images at limited spatial resolution. , 2009, Bone.

[26]  L. Gibson,et al.  Modeling the mechanical behavior of vertebral trabecular bone: effects of age-related changes in microstructure. , 1997, Bone.

[27]  Zi-xiang Wu,et al.  A New Method of Partial Screw Augmentation in Sheep Vertebrae In Vitro: Biomechanical and Interfacial Evaluation , 2011, Journal of spinal disorders & techniques.

[28]  C. Shim,et al.  Anterior bone cement augmentation in anterior lumbar interbody fusion and percutaneous pedicle screw fixation in patients with osteoporosis. , 2010, Journal of neurosurgery. Spine.

[29]  S. Cook,et al.  Effects of Bone Mineral Density on Pedicle Screw Fixation , 1994, Spine.

[30]  S. Chou,et al.  Investigation of fixation screw pull-out strength on human spine. , 2004, Journal of biomechanics.

[31]  W. Plitz,et al.  Stability of Pedicle Screws After Kyphoplasty Augmentation: An Experimental Study to Compare Transpedicular Screw Fixation in Soft and Cured Kyphoplasty Cement , 2006, Journal of spinal disorders & techniques.

[32]  W. Lo,et al.  Biomechanical evaluation of a new anterior spinal implant. , 1998, Clinical biomechanics.

[33]  R M Harrington,et al.  Factors affecting the pullout strength of cancellous bone screws. , 1996, Journal of biomechanical engineering.

[34]  Yang Zhang,et al.  Surgical treatment of osteoporotic thoracolumbar compressive fractures with open vertebral cement augmentation of expandable pedicle screw fixation: a biomechanical study and a 2-year follow-up of 20 patients. , 2012, The Journal of surgical research.

[35]  Zi-xiang Wu,et al.  Augmentation of Pedicle Screw Stability With Calcium Sulfate Cement in Osteoporotic Sheep: Biomechanical and Screw-bone Interfacial Evaluation , 2011, Journal of spinal disorders & techniques.

[36]  Ming-Chau Chang,et al.  Polymethylmethacrylate Augmentation of Pedicle Screw for Osteoporotic Spinal Surgery: A Novel Technique , 2008, Spine.

[37]  B. V. van Royen,et al.  Augmentation of (pedicle) screws with calcium apatite cement in patients with severe progressive osteoporotic spinal deformities: an innovative technique , 2000, European Spine Journal.