Optimal-arrangement-based four-scanning-heads error separation technique for self-calibration of angle encoders

Conventional methods for the calibration of angle encoders typically only consider the graduation error of the encoder's circular scale. However, the radial motion of the circular scale during its rotation, due to its eccentricity and the axis of rotation radial error motion, can also introduce noticeable errors to the angle measurement in most practical applications. Based on the analysis of the influence of radial motion, an optimal-arrangement-based four-scanning-heads error separation technique for in situ self-calibration of angle encoders is presented. This Fourier-based technique uses the basic self-calibration model to measure the first-order Fourier component of the encoder error which includes the contribution of eccentricity. Meanwhile, the separation technique is utilized to separate the residual Fourier components of the graduation error from the measurement deviation due to radial error motion. The effect of the scanning heads' angular position errors on the calibration results is discussed. Optimal arrangements of the four heads are achieved to avoid the suppression of the Fourier components, and reduce the propagation of errors. Numerical results and experimental comparisons demonstrate the effectiveness of the proposed method. Moreover, this technique can also be used for measuring the spindle radial error motion for some users.

[1]  Wei Gao,et al.  High-accuracy roundness measurement by a new error separation method , 1997 .

[2]  Kuang-Chao Fan,et al.  A novel method of angular positioning error analysis of rotary stages based on the Abbe principle , 2018 .

[3]  Eric R. Marsh,et al.  A comparison of reversal and multiprobe error separation , 2010 .

[4]  Pinkuan Liu,et al.  Optimal arrangements of scanning heads for self-calibration of angle encoders , 2017 .

[5]  R. Probst Self-calibration of divided circles on the basis of a prime factor algorithm , 2007 .

[6]  Kayoko Taniguchi,et al.  An angle encoder for super-high resolution and super-high accuracy using SelfA , 2014 .

[7]  Darya Amin-Shahidi,et al.  On-axis self-calibration of angle encoders , 2010 .

[8]  C. Elster,et al.  Calibration of angle encoders using transfer functions , 2006 .

[9]  David L. Trumper,et al.  Self-Calibration of On-Axis Rotary Encoders , 2007 .

[10]  Dominiek Reynaerts,et al.  A sub-nanometre spindle error motion separation technique , 2014 .

[11]  Ralf D. Geckeler,et al.  New frontiers in angle metrology at the PTB , 2015 .

[12]  M. Krause,et al.  The new PTB angle comparator , 1998 .

[13]  Hiroyuki Fujimoto,et al.  Self-calibratable rotary encoder , 2005 .

[14]  Robert J. Hocken,et al.  Self-Calibration: Reversal, Redundancy, Error Separation, and ‘Absolute Testing’ , 1996 .

[15]  W. Tyler Estler,et al.  Uncertainty Analysis for Angle Calibrations Using Circle Closure , 1998, Journal of research of the National Institute of Standards and Technology.

[16]  Makoto Kajitani,et al.  Automatic high-precision calibration system for angle encoder (II) , 2001, SPIE Optics + Photonics.

[17]  Makoto Kajitani,et al.  Automatic high-precision calibration system for angle encoder , 2001, Lasers in Metrology and Art Conservation.

[18]  David J. Whitehouse,et al.  Some theoretical aspects of error separation techniques in surface metrology , 1976 .

[19]  Ralf D. Geckeler,et al.  Capabilities and limitations of the self-calibration of angle encoders , 2014 .

[20]  Harald Bosse,et al.  Comparison of angle standards with the aid of a high-resolution angle encoder , 2009 .

[21]  S Asli Akgoz,et al.  Calibration of high-resolution electronic autocollimators with demanded low uncertainties using single reading head angle encoders , 2013 .