Use of dual Euler angles to quantify the three-dimensional joint motion and its application to the ankle joint complex.

This paper presents a modified Euler angles method, dual Euler angles approach, to describe general spatial human joint motions. In dual Euler angles approach, the three-dimensional joint motion is considered as three successive screw motions with respect to the axes of the moving segment coordinate system; accordingly, the screw motion displacements are represented by dual Euler angles. The algorithm for calculating dual Euler angles from coordinates of markers on the moving segment is also provided in this study. As an example, the proposed method is applied to describe motions of ankle joint complex during dorsiflexion-plantarflexion. A Flock of Birds electromagnetic tracking device (FOB) was used to measure joint motion in vivo. Preliminary accuracy tests on a gimbal structure demonstrate that the mean errors of dual Euler angles evaluated by using source data from FOB are less than 1 degrees for rotations and 1mm for translations, respectively. Based on the pilot study, FOB is feasible for quantifying human joint motions using dual Euler angles approach.

[1]  Cliff B. Jones,et al.  A tracking system , 1998 .

[2]  E. Chao,et al.  Justification of triaxial goniometer for the measurement of joint rotation. , 1980, Journal of biomechanics.

[3]  H R Busby,et al.  Smoothing noisy data using dynamic programming and generalized cross-validation. , 1988, Journal of biomechanical engineering.

[4]  A. T. Yang Displacement Analysis of Spatial Five-Link Mechanisms Using (3×3) Matrices With Dual-Number Elements , 1969 .

[5]  G K Cole,et al.  Application of the joint coordinate system to three-dimensional joint attitude and movement representation: a standardization proposal. , 1993, Journal of biomechanical engineering.

[6]  F. V. D. van der Helm,et al.  Calibration of the "Flock of Birds" electromagnetic tracking device and its application in shoulder motion studies. , 1999, Journal of biomechanics.

[7]  E S Grood,et al.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.

[8]  H. Woltring 3-D attitude representation of human joints: a standardization proposal. , 1994, Journal of biomechanics.

[9]  V. M. Zat︠s︡iorskiĭ Kinematics of human motion , 1998 .

[10]  G L Kinzel,et al.  Measurement of the total motion between two body segments. I. Analytical development. , 1972, Journal of biomechanics.

[11]  T D Brown,et al.  Factors influencing accuracy of screw displacement axis detection with a D.C.-based electromagnetic tracking system. , 1998, Journal of biomechanical engineering.

[12]  L Blankevoort,et al.  Helical axes of passive knee joint motions. , 1990, Journal of biomechanics.

[13]  Ian S. Fischer,et al.  Dual-Number Methods in Kinematics, Statics and Dynamics , 1998 .

[14]  R. Fletcher Practical Methods of Optimization , 1988 .

[15]  A A Amis,et al.  Accuracy of an electromagnetic measurement device and application to the measurement and description of knee joint motion , 1998, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[16]  S. Siegler,et al.  The three-dimensional kinematics and flexibility characteristics of the human ankle and subtalar joints--Part I: Kinematics. , 1988, Journal of biomechanical engineering.