A Fast Crystal Identification Algorithm Applied to the LabPET™ Phoswich Detectors

Detectors based on LYSO and LGSO scintillators in a phoswich arrangement coupled to an avalanche photodiode are used in the LabPETtrade, an all-digital positron emission tomography (PET) scanner for small animal imaging developed in Sherbrooke. A Wiener filter based crystal identification (CI) algorithm achieving excellent discrimination accuracy was recently proposed for crystal identification of LYSO-LGSO phoswich detectors . This algorithm was based on estimating parameters describing the scintillation decay time constant and the light yield of events sampled at 45 MSPS. The CI process was performed by applying a threshold on the scintillation decay parameter of events. The light yield was not considered in the CI process even if it should be. We propose a 2-fold faster CI approach which takes both the scintillation decay and light yield coefficients of each crystal into consideration. The new algorithm uses the previous Wiener filter based algorithm as a calibration process in order to evaluate the model of each individual crystal. The DAQ chain model as a priori knowledge is then incorporated into the model of each crystal and the output signal is estimated. The CI is performed by evaluating a single parameter representing the percentage contribution of each crystal characteristics in the event signal. The CI algorithm demonstrated a discrimination rate accuracy for LYSO-LGSO LabPET detectors and for LSO-GSO crystals in phoswich arrangement for 511 keV events. Although a calibration is required, the real-time implementation of the new CI algorithm needs 2 times less direct operations. An FPGA clocked at 400 MHz can process up to 25 M events/sec with such an algorithm.

[1]  W. W. Moses,et al.  A LSO scintillator array for a PET detector module with depth of interaction measurement , 2000, 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149).

[2]  Vesna Sossi,et al.  Effect of depth of interaction decoding on resolution in PET: A simulation study , 2002 .

[3]  R. Fontaine,et al.  Performance evaluation of the LabPET™ APD-based digital PET scanner , 2009, 2007 IEEE Nuclear Science Symposium Conference Record.

[4]  R. Fontaine,et al.  Crystal identification based on recursive-least-squares and least-mean-squares autoregressive models for small animal PET , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[5]  R. Fontaine,et al.  Experimental results of identification and vector quantization algorithms for DOI measurement in digital PET scanners with phoswich detectors , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[6]  R. Fontaine,et al.  Real Time Implementation of a Wiener Filter Based Crystal Identification Algorithm , 2008, IEEE Transactions on Nuclear Science.

[7]  R. Fontaine,et al.  Timing improvement by low-pass filtering and linear interpolation for the LabPETTM scanner , 2007, 2007 15th IEEE-NPSS Real-Time Conference.

[8]  R. Fontaine,et al.  Crystal Identification Based on Recursive-Least-Squares and Least-Mean-Squares Auto-Regressive Models for Small Animal Pet , 2008, IEEE Transactions on Nuclear Science.

[9]  T. Lewellen,et al.  Design of a depth of interaction (DOI) PET detector module , 1997, 1997 IEEE Nuclear Science Symposium Conference Record.

[10]  R. Lecomte,et al.  A novel APD-based detector module for multi-modality PET/SPECT/CT scanners , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[11]  R. Fontaine,et al.  Roadmap to fully-digital PET/CT scanners , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[12]  R. Fontaine,et al.  Real Time Implementation of a Wiener Filter Based Crystal Identification Algorithm for Photon Counting CT Imaging , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[13]  Simon Haykin,et al.  Adaptive Filter Theory 4th Edition , 2002 .

[14]  R. Fontaine,et al.  Design and performance of 0.18-/spl mu/m CMOS charge preamplifiers for APD-based PET scanners , 2004, IEEE Transactions on Nuclear Science.

[15]  R. Fontaine,et al.  The architecture of LabPET/spl trade/, a small animal APD-based digital PET scanner , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[16]  Magnus Dahlbom,et al.  Parallax correction in PET using depth of interaction information , 1997, 1997 IEEE Nuclear Science Symposium Conference Record.

[17]  R. Fontaine,et al.  Timing Improvement by Low-Pass Filtering and Linear Interpolation for the LabPET Scanner , 2008, IEEE Transactions on Nuclear Science.

[18]  R. Fontaine,et al.  ARMAX model and recursive least-squares identification for DOI measurement in PET , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[19]  Horst Halling,et al.  Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET , 2002 .

[20]  R. Farrell,et al.  Evaluation of a prototype small-animal PET detector with depth-of-interaction encoding , 2004, IEEE Transactions on Nuclear Science.

[21]  R. Fontaine,et al.  Design and Performance of 0 . 18-m CMOS Charge Preamplifiers for APD-Based PET Scanners , 2009 .