Biomechanical Evaluation of the Less Invasive Stabilization System for the Internal Fixation of Distal Femur Fractures

Objective Comparison between a Less Invasive Stabilization System (LISS) using monocortical screws with angular stability and two conventional plate systems Condylar Buttress Plate (CBP) and Dynamic Condylar Screw (DCS) for the treatment of distal femoral fractures with respect to biomechanical properties. Design Biomechanical study using paired cadaver femurs. In Test Configuration 1 (distal test), a ten-millimeter gap at the diaphysis–metaphysis junction simulates a supracondylar femoral fracture. Test Configuration 2 (proximal test) has the same configuration, but the gap was cut in the isthmic region. Proximal and distal plate ends were fixed to corresponding cortical bone fragments in both tests. Optical displacement transducers served to quantify the system's ability to withstand a stepwise increased load. Reversible (deflection) and irreversible deformation (subsidence) of the bone–plate construct was investigated. Results In Test Configuration 1, LISS showed less irreversible deformation in 72 percent of the left–right comparisons. No correlation between bone mineral density, cross-section area of bones and the measured response of the construct under load was found between pairs. In Test Configuration 2, 83 percent of the left–right comparisons showed less permanent deformation but a higher elastic deformation for LISS. Conclusions These results suggest an enhanced ability to withstand high loads when using the monocortical screw fixation technique with angular stability. A higher elastic deformation of LISS compared with conventional plating systems in distal femoral fractures can be explained by the lower bending stiffness caused by different design and material properties.

[1]  F. Kummer,et al.  Distal femoral fixation: A laboratory comparison of the 95° plate, antegrade and retrograde inserted reamed intramedullary nails , 1996 .

[2]  F. Kummer,et al.  Distal femoral fixation: a biomechanical comparison of the standard condylar buttress plate, a locked buttress plate, and the 95-degree blade plate. , 1997, Journal of orthopaedic trauma.

[3]  M. Swiontkowski,et al.  Angulated screw placement in the lateral condylar buttress plate for supracondylar femoral fractures. , 1998, Injury.

[4]  M. Swiontkowski,et al.  Double-plating of comminuted, unstable fractures of the distal part of the femur. , 1991, The Journal of bone and joint surgery. American volume.

[5]  K. Ito,et al.  Internal fixation of supracondylar femoral fractures: comparative biomechanical performance of the 95-degree blade plate and two retrograde nails. , 1998, Journal of orthopaedic trauma.

[6]  C. Krettek,et al.  Minimally invasive percutaneous plate osteosynthesis (MIPPO) using the DCS in proximal and distal femoral fractures. , 1997, Injury.

[7]  M. Panjabi,et al.  Dynamic Compression Plate Fixation: A Biomechanical Comparison of Unicortical vs Bicortical Distal Screw Fixation , 1988, Journal of orthopaedic trauma.

[8]  M. Müller,et al.  Manual of Internal Fixation , 1970, Springer Berlin Heidelberg.

[9]  C. Krettek Foreword: concepts of minimally invasive plate osteosynthesis. , 1997, Injury.

[10]  K. Firoozbakhsh,et al.  Mechanics of Retrograde Nail Versus Plate Fixation for Supracondylar Femur Fractures , 1995, Journal of orthopaedic trauma.