A Nonproprietary Movement Analysis System (MoJoXlab) Based on Wearable Inertial Measurement Units Applicable to Healthy Participants and Those With Anterior Cruciate Ligament Reconstruction Across a Range of Complex Tasks: Validation Study

Background Movement analysis in a clinical setting is frequently restricted to observational methods to inform clinical decision making, which has limited accuracy. Fixed-site, optical, expensive movement analysis laboratories provide gold standard kinematic measurements; however, they are rarely accessed for routine clinical use. Wearable inertial measurement units (IMUs) have been demonstrated as comparable, inexpensive, and portable movement analysis toolkits. MoJoXlab has therefore been developed to work with generic wearable IMUs. However, before using MoJoXlab in clinical practice, there is a need to establish its validity in participants with and without knee conditions across a range of tasks with varying complexity. Objective This paper aimed to present the validation of MoJoXlab software for using generic wearable IMUs for calculating hip, knee, and ankle joint angle measurements in the sagittal, frontal, and transverse planes for walking, squatting, and jumping in healthy participants and those with anterior cruciate ligament (ACL) reconstruction. Methods Movement data were collected from 27 healthy participants and 20 participants with ACL reconstruction. In each case, the participants wore seven MTw2 IMUs (Xsens Technologies) to monitor their movement in walking, jumping, and squatting tasks. The hip, knee, and ankle joint angles were calculated in the sagittal, frontal, and transverse planes using two different software packages: Xsens’ validated proprietary MVN Analyze and MoJoXlab. The results were validated by comparing the generated waveforms, cross-correlation (CC), and normalized root mean square error (NRMSE) values. Results Across all joints and activities, for data of both healthy and ACL reconstruction participants, the CC and NRMSE values for the sagittal plane are 0.99 (SD 0.01) and 0.042 (SD 0.025); 0.88 (SD 0.048) and 0.18 (SD 0.078) for the frontal plane; and 0.85 (SD 0.027) and 0.23 (SD 0.065) for the transverse plane (hip and knee joints only). On comparing the results from the two different software systems, the sagittal plane was very highly correlated, with frontal and transverse planes showing strong correlation. Conclusions This study demonstrates that nonproprietary software such as MoJoXlab can accurately calculate joint angles for movement analysis applications comparable with proprietary software for walking, squatting, and jumping in healthy individuals and those following ACL reconstruction. MoJoXlab can be used with generic wearable IMUs that can provide clinicians accurate objective data when assessing patients’ movement, even when changes are too small to be observed visually. The availability of easy-to-setup, nonproprietary software for calibration, data collection, and joint angle calculation has the potential to increase the adoption of wearable IMU sensors in clinical practice, as well as in free living conditions, and may provide wider access to accurate, objective assessment of patients’ progress over time.

[1]  T. Krosshaug,et al.  Sagittal Plane Hip, Knee, and Ankle Biomechanics and the Risk of Anterior Cruciate Ligament Injury: A Prospective Study , 2017, Orthopaedic journal of sports medicine.

[2]  Noel E. O'Connor,et al.  Automatic Activity Classification and Movement Assessment During a Sports Training Session Using Wearable Inertial Sensors , 2014, 2014 11th International Conference on Wearable and Implantable Body Sensor Networks.

[3]  Qingguo Li,et al.  Concurrent validation of Xsens MVN measurement of lower limb joint angular kinematics , 2013, Physiological measurement.

[4]  Robert L Mauck,et al.  Measuring clinically relevant knee motion with a self-calibrated wearable sensor. , 2019, Journal of biomechanics.

[5]  E S Grood,et al.  A joint coordinate system for the clinical description of three-dimensional motions: application to the knee. , 1983, Journal of biomechanical engineering.

[6]  Hartmut Witte,et al.  ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion--part I: ankle, hip, and spine. International Society of Biomechanics. , 2002, Journal of biomechanics.

[7]  Eduardo Rocon,et al.  An IMU-to-Body Alignment Method Applied to Human Gait Analysis , 2016, Sensors.

[8]  T. Lu,et al.  Biomechanics of human movement and its clinical applications , 2012, The Kaohsiung journal of medical sciences.

[9]  Hossein Rouhani,et al.  Sensor-to-body calibration procedure for clinical motion analysis of lower limb using magnetic and inertial measurement units. , 2019, Journal of biomechanics.

[10]  L. Engebretsen,et al.  The Scandinavian ACL registries 2004–2007: baseline epidemiology , 2009, Acta orthopaedica.

[11]  C. Mazzà,et al.  A least-squares identification algorithm for estimating squat exercise mechanics using a single inertial measurement unit. , 2012, Journal of biomechanics.

[12]  M. Nussbaum,et al.  Postural sway and joint kinematics during quiet standing are affected by lumbar extensor fatigue. , 2006, Human movement science.

[13]  M H Granat,et al.  A practical gait analysis system using gyroscopes. , 1999, Medical engineering & physics.

[14]  Dieter Rosenbaum,et al.  on definitions of joint coordinate system of various joints for the reporting of human joint motion — part I : ankle , hip , and spine , 2002 .

[15]  William Johnston,et al.  Wearable Inertial Sensor Systems for Lower Limb Exercise Detection and Evaluation: A Systematic Review , 2018, Sports Medicine.

[16]  K. Samuelsson,et al.  Treatment of anterior cruciate ligament injuries with special reference to surgical technique and rehabilitation: an assessment of randomized controlled trials. , 2009, Arthroscopy: The Journal of Arthroscopy And Related.

[17]  Christian Larue,et al.  Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis , 2017, Medical & Biological Engineering & Computing.

[18]  Andrea Giovanni Cutti,et al.  Gait analysis in children with cerebral palsy via inertial and magnetic sensors , 2012, Medical & Biological Engineering & Computing.

[19]  M. Izquierdo,et al.  Acceleration and Orientation Jumping Performance Differences Among Elite Professional Male Handball Players With or Without Previous ACL Reconstruction: An Inertial Sensor Unit‐Based Study , 2015, PM & R : the journal of injury, function, and rehabilitation.

[20]  M. Pearcy,et al.  A three-dimensional definition for the flexion/extension and abduction/adduction angles , 1999, Medical & Biological Engineering & Computing.

[21]  S. Bollen Epidemiology of knee injuries: diagnosis and triage , 2000, British journal of sports medicine.

[22]  F. V. D. van der Helm,et al.  Magnetic distortion in motion labs, implications for validating inertial magnetic sensors. , 2009, Gait & posture.

[23]  K. Webster,et al.  Fifty-five per cent return to competitive sport following anterior cruciate ligament reconstruction surgery: an updated systematic review and meta-analysis including aspects of physical functioning and contextual factors , 2014, British Journal of Sports Medicine.

[24]  S. M. N. Arosha Senanayake,et al.  Identifying gait asymmetry using gyroscopes--a cross-correlation and Normalized Symmetry Index approach. , 2011, Journal of biomechanics.

[25]  P. Roos,et al.  Altered biomechanical strategies and medio-lateral control of the knee represent incomplete recovery of individuals with injury during single leg hop☆ , 2014, Journal of biomechanics.

[26]  Kate Button,et al.  Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity , 2018, Sensors.

[27]  N. Sasanelli,et al.  Evaluation of Standing Vertical Jump by Ankles Acceleration Measurement , 2010, Journal of strength and conditioning research.

[28]  P. Roos,et al.  Motor control strategies during double leg squat following anterior cruciate ligament rupture and reconstruction: an observational study , 2014, Journal of NeuroEngineering and Rehabilitation.

[29]  P. Roos,et al.  Activity progression for anterior cruciate ligament injured individuals☆ , 2014, Clinical biomechanics.

[30]  Tao Liu,et al.  Triaxial joint moment estimation using a wearable three-dimensional gait analysis system , 2014 .

[31]  Yoon Hyuk Kim,et al.  Consistent accuracy in whole-body joint kinetics during gait using wearable inertial motion sensors and in-shoe pressure sensors. , 2015, Gait & posture.

[32]  Pietro Garofalo,et al.  First in vivo assessment of “Outwalk”: a novel protocol for clinical gait analysis based on inertial and magnetic sensors , 2009, Medical & Biological Engineering & Computing.

[33]  L. Good,et al.  Long‐term results after primary repair or non‐surgical treatment of anterior cruciate ligament rupture: a randomized study with a 15‐year follow‐up , 2006, Scandinavian journal of medicine & science in sports.

[34]  Vincent Bonnet,et al.  Real-time Estimate of Body Kinematics During a Planar Squat Task Using a Single Inertial Measurement Unit , 2013, IEEE Transactions on Biomedical Engineering.

[35]  Roberto Nerino,et al.  A BSN based service for post-surgical knee rehabilitation at home , 2013, BODYNETS.

[36]  Thomas Seel,et al.  IMU-Based Joint Angle Measurement for Gait Analysis , 2014, Sensors.

[37]  Vincent Bonnet,et al.  An optimization algorithm for joint mechanics estimate using inertial measurement unit data during a squat task , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[38]  P R Cavanagh,et al.  ISB recommendations for standardization in the reporting of kinematic data. , 1995, Journal of biomechanics.