Redefining functional sensitivity of thyroglobulin assay on Immulite platform: implications in thyroid cancer management.

Circulating thyroglobulin (Tg) measurement after thyrotropin stimulation is a pivotal tool in the management of patients affected by differentiated thyroid carcinoma. The Tg assay on Immulite platform has a declared functional sensitivity of 0.9 ng/mL and it is widely used in clinical practice and research on thyroid carcinoma. Recently, thyroglobulin measured during thyroxine treatment was found to be adequate for thyroid carcinoma follow-up if functional sensitivity at 0.2-0.3 ng/mL was reached by assay methods. Thus, the present study was then undertaken to evaluate the imprecision of Immulite Tg assay at very low concentrations. The detection limit was calculated on zero calibrator and Tg-free pooled sera replicates and was 0.14 and 0.16 ng/mL, respectively. Different serum pools with Tg concentrations ranging from 0.16 to 2.50 ng/mL were assayed according to the National Academy of Clinical Biochemistry guidelines to estimate functional sensitivity. By interpolating the imprecision profile with a coefficient of variation of 20%, the functional sensitivity was 0.36 ng/mL. The Immulite-Tg assay was directly compared with a high-sensitive immunoradiometric Tg assay in sera from 93 patients with thyroid carcinomas. No significant differences in sensitivity and specificity were observed by using the newly defined functional sensitivity. In conclusion, the Immulite Tg assay showed a lower functional sensitivity than expected and performed comparably to high-sensitive immunoradiometric assay in patients with thyroid carcinoma.

[1]  S. Koscielny,et al.  Comparison of seven serum thyroglobulin assays in the follow-up of papillary and follicular thyroid cancer patients. , 2007, The Journal of clinical endocrinology and metabolism.

[2]  T. A. Fagundes,et al.  Is stimulation of thyroglobulin (Tg) useful in low‐risk patients with thyroid carcinoma and undetectable Tg on thyroxin and negative neck ultrasound? , 2005, Clinical endocrinology.

[3]  A. Pinchera,et al.  Recombinant human thyrotropin-stimulated serum thyroglobulin combined with neck ultrasonography has the highest sensitivity in monitoring differentiated thyroid carcinoma. , 2003, The Journal of clinical endocrinology and metabolism.

[4]  Stephanie L. Lee,et al.  A consensus report of the role of serum thyroglobulin as a monitoring method for low-risk patients with papillary thyroid carcinoma. , 2003, The Journal of clinical endocrinology and metabolism.

[5]  A. Pinchera,et al.  Diagnostic 131-iodine whole-body scan may be avoided in thyroid cancer patients who have undetectable stimulated serum Tg levels after initial treatment. , 2002, The Journal of clinical endocrinology and metabolism.

[6]  L. Ceriani,et al.  High-Sensitivity Human Thyroglobulin (hTG) Immunoradiometric Assay in the Follow-up of Patients with Differentiated Thyroid Cancer , 2002, Clinical chemistry and laboratory medicine.

[7]  T. P. Fox,et al.  Monitoring thyroglobulin in a sensitive immunoassay has comparable sensitivity to recombinant human tsh-stimulated thyroglobulin in follow-up of thyroid cancer patients. , 2007, The Journal of clinical endocrinology and metabolism.

[8]  L. Ceriani,et al.  Thyroglobulin assay during thyroxine treatment in low-risk differentiated thyroid cancer management: comparison with recombinant human thyrotropin-stimulated assay and imaging procedures , 2006, Clinical chemistry and laboratory medicine.

[9]  P. Knesewitsch,et al.  Evaluation of the First Automated Thyroglobulin Assay , 1999, Clinical chemistry and laboratory medicine.