Improved slant column density retrieval of nitrogen dioxide and formaldehyde for OMI and GOME-2A from QA4ECV: intercomparison, uncertainty characterisation, and trends

Abstract. Nitrogen dioxide (NO2) and formaldehyde (HCHO) column data from satellite instruments are used for air quality and climate studies. Both NO2 and HCHO have been identified as precursors to the ozone (O3) and aerosol essential climate variables, and it is essential to quantify and characterise their uncertainties. Here we present an intercomparison of NO2 and HCHO slant column density (SCD) retrievals from four different research groups (BIRA-IASB, IUP Bremen, and KNMI as part of the Quality Assurance for Essential Climate Variables (QA4ECV) project consortium, and NASA) and from the OMI and GOME-2A instruments. Our evaluation is motivated by recent improvements in differential optical absorption spectroscopy (DOAS) fitting techniques and by the desire to provide a fully traceable uncertainty budget for the climate data record generated within QA4ECV. The improved NO2 and HCHO SCD values are in close agreement but with substantial differences in the reported uncertainties between groups and instruments. To check the DOAS uncertainties, we use an independent estimate based on the spatial variability of the SCDs within a remote region. For NO2, we find the smallest uncertainties from the new QA4ECV retrieval (0.8  ×  1015 molec. cm−2 for both instruments over their mission lifetimes). Relative to earlier approaches, the QA4ECV NO2 retrieval shows better agreement between DOAS and statistical uncertainty estimates, suggesting that the improved QA4ECV NO2 retrieval has reduced but not altogether eliminated systematic errors in the fitting approach. For HCHO, we reach similar conclusions (QA4ECV uncertainties of 8–12  ×  1015 molec. cm−2), but the closeness between the DOAS and statistical uncertainty estimates suggests that HCHO uncertainties are indeed dominated by random noise from the satellite's level 1 data. We find that SCD uncertainties are smallest for high top-of-atmosphere reflectance levels with high measurement signal-to-noise ratios. From 2005 to 2015, OMI NO2 SCD uncertainties increase by 1–2 % year−1, which is related to detector degradation and stripes, but OMI HCHO SCD uncertainties are remarkably stable (increase  <  1 % year−1) and this is related to the use of Earth radiance reference spectra which reduces stripes. For GOME-2A, NO2 and HCHO SCD uncertainties increased by 7–9 and 11–15 % year−1 respectively up until September 2009, when heating of the instrument markedly reduced further throughput loss, stabilising the degradation of SCD uncertainty to  <  3 % year−1 for 2009–2015. Our work suggests that the NO2 SCD uncertainty largely consists of a random component ( ∼  65 % of the total uncertainty) as a result of the propagation of measurement noise but also of a substantial systematic component ( ∼  35 % of the total uncertainty) mainly from stripe effects. Averaging over multiple pixels in space and/or time can significantly reduce the SCD uncertainties. This suggests that trend detection in OMI, GOME-2 NO2, and HCHO time series is not limited by the spectral fitting but rather by the adequacy of assumptions on the atmospheric state in the later air mass factor (AMF) calculation step.

[1]  K. F. Boersma,et al.  Near-real time retrieval of tropospheric NO2 from OMI , 2020 .

[2]  Steffen Beirle,et al.  An improved total and tropospheric NO2 column retrieval for GOME-2 , 2016, Atmospheric Measurement Techniques.

[3]  J. Lampel Algorithm theoretical baseline for formaldehyde retrievals from S 5 P TROPOMI and from the QA 4 ECV project , 2018 .

[4]  Thomas Wagner,et al.  Algorithm theoretical baseline for formaldehyde retrievals from S5P TROPOMI and from the QA4ECV project , 2017 .

[5]  Nickolay A. Krotkov,et al.  The version 3 OMI NO 2 standard product , 2017 .

[6]  U. Platt Air Monitoring by Differential Optical Absorption Spectroscopy , 2017 .

[7]  Glen Jaross,et al.  In-flight performance of the Ozone Monitoring Instrument. , 2017, Atmospheric measurement techniques.

[8]  K. Sun,et al.  Deriving the slit functions from OMI solar observations and its implications for ozone-profile retrieval , 2017 .

[9]  D. Jacob,et al.  Formaldehyde (HCHO) As a Hazardous Air Pollutant: Mapping Surface Air Concentrations from Satellite and Inferring Cancer Risks in the United States. , 2017, Environmental science & technology.

[10]  A. Lorente,et al.  Tropospheric HCHO retrieved from OMI, GOME(-2), and SCIAMACHY within the Quality Assurance For Essential Climate Variables (QA4ECV) project , 2017 .

[11]  Yang Wang,et al.  Structural uncertainty in air mass factor calculation for NO2 and HCHO satellite retrievals , 2016 .

[12]  Willem W. Verstraeten,et al.  Spaceborne Sun-Induced Vegetation Fluorescence Time Series from 2007 to 2015 Evaluated with Australian Flux Tower Measurements , 2016, Remote. Sens..

[13]  Steffen Beirle,et al.  Parameterizing the instrumental spectral response function and its changes by a super-Gaussian and its derivatives , 2016 .

[14]  Henk Eskes,et al.  Decadal changes in global surface NO x emissions from multi-constituent satellite data assimilation , 2016 .

[15]  Steffen Beirle,et al.  The STRatospheric Estimation Algorithm from Mainz (STREAM):estimating stratospheric NO 2 from nadir-viewing satellites by weighted convolution , 2016 .

[16]  Richard D. McPeters,et al.  OMI total column ozone: extending the long-term data record , 2015 .

[17]  Nicolas Theys,et al.  Diurnal, seasonal and long-term variations of global formaldehyde columns inferred from combined OMI and GOME-2 observations , 2015 .

[18]  Jessica L. Neu,et al.  Rapid increases in tropospheric ozone production and export from China , 2015 .

[19]  Michael Eisinger,et al.  The GOME-2 instrument on the Metop series of satellites: instrument design, calibration, and level 1 data processing – an overview , 2015 .

[20]  N. A. Krotkov,et al.  Revising the slant column density retrieval of nitrogen dioxide observed by the Ozone Monitoring Instrument , 2015, Journal of geophysical research. Atmospheres : JGR.

[21]  David G. Streets,et al.  U.S. NO2 trends (2005–2013): EPA Air Quality System (AQS) data versus improved observations from the Ozone Monitoring Instrument (OMI) , 2015 .

[22]  R. Beelen,et al.  Air Pollution and Mortality in Seven Million Adults: The Dutch Environmental Longitudinal Study (DUELS) , 2015, Environmental health perspectives.

[23]  Xiong Liu,et al.  Updated Smithsonian Astrophysical Observatory Ozone Monitoring Instrument (SAO OMI) formaldehyde retrieval , 2015 .

[24]  J. Burrows,et al.  Liquid water absorption and scattering effects in DOAS retrievals over oceans , 2014 .

[25]  F. Hendrick,et al.  Improved spectral fitting of nitrogen dioxide from OMI in the 405–465 nm window , 2014 .

[26]  Roland J. Leigh,et al.  An improved retrieval of tropospheric NO 2 from space over polluted regions using an Earth radiance reference , 2014 .

[27]  C. Frankenberg,et al.  Global monitoring of terrestrial chlorophyll fluorescence from moderate-spectral-resolution near-infrared satellite measurements: methodology, simulations, and application to GOME-2 , 2013 .

[28]  James F. Gleason,et al.  A new stratospheric and tropospheric NO2 retrieval algorithm for nadir-viewing satellite instruments : applications to OMI , 2013 .

[29]  Nicolas Theys,et al.  Improved retrieval of global tropospheric formaldehyde columns from GOME-2/MetOp-A addressing noise reduction and instrumental degradation issues , 2012 .

[30]  B. Dix,et al.  The CU ground MAX-DOAS instrument: characterization of RMS noise limitations and first measurements near Pensacola, FL of BrO, IO, and CHOCHO , 2011 .

[31]  Henk Eskes,et al.  An improved tropospheric NO 2 column retrieval algorithm for the Ozone Monitoring Instrument , 2011 .

[32]  Pieter Valks,et al.  Operational total and tropospheric NO 2 column retrieval for GOME-2 , 2011 .

[33]  Andreas Hilboll,et al.  An improved NO 2 retrieval for the GOME-2 satellite instrument , 2011 .

[34]  Henk Eskes,et al.  Evaluation of stratospheric NO2 retrieved from the Ozone Monitoring Instrument : intercomparison, diurnal cycle and trending , 2011 .

[35]  GOME-2 on MetOp-A Support for Analysis of GOME-2 In-Orbit Degradation and Impacts on Level 2 Data Products Final Report , 2011 .

[36]  U. Platt,et al.  Extending differential optical absorption spectroscopy for limb measurements in the UV , 2010 .

[37]  P. Bernath,et al.  Global upper-tropospheric formaldehyde: seasonal cycles observed by the ACE-FTS satellite instrument , 2009 .

[38]  K. Boersma,et al.  Reductions of NO2 detected from space during the 2008 Beijing Olympic Games , 2009 .

[39]  Henk Eskes,et al.  Twelve years of global observations of formaldehyde in the troposphere using GOME and SCIAMACHY sensors , 2008 .

[40]  Glen Jaross,et al.  Validation of Ozone Monitoring Instrument level 1b data products , 2008 .

[41]  K. F. Boersma,et al.  Spatial distribution of isoprene emissions from North America derived from formaldehyde column measurements by the OMI satellite sensor , 2008 .

[42]  R. Spurr LIDORT and VLIDORT: Linearized pseudo-spherical scalar and vector discrete ordinate radiative transfer models for use in remote sensing retrieval problems , 2008 .

[43]  David G. Streets,et al.  Nitrate aerosols today and in 2030: a global simulation including aerosols and tropospheric ozone , 2007 .

[44]  H. L. Miller,et al.  Climate Change 2007: The Physical Science Basis , 2007 .

[45]  K. F. Boersma,et al.  Near-real time retrieval of tropospheric NO 2 from OMI , 2006 .

[46]  Robert Voors,et al.  Prelaunch characterization of the Ozone Monitoring Instrument transfer function in the spectral domain. , 2006, Applied optics.

[47]  Robert Voors,et al.  Method of calibration to correct for cloud-induced wavelength shifts in the Aura satellite's Ozone Monitoring Instrument. , 2006, Applied optics.

[48]  James F. Gleason,et al.  Algorithm for NO/sub 2/ vertical column retrieval from the ozone monitoring instrument , 2006, IEEE Transactions on Geoscience and Remote Sensing.

[49]  Heikki Saari,et al.  The ozone monitoring instrument , 2006, IEEE Transactions on Geoscience and Remote Sensing.

[50]  Glen Jaross,et al.  Ozone monitoring instrument calibration , 2006, IEEE Transactions on Geoscience and Remote Sensing.

[51]  Henk Eskes,et al.  Error analysis for tropospheric NO2 retrieval from space , 2004 .

[52]  Bernd Jähne,et al.  Quantitative analysis of NO x emissions from Global Ozone Monitoring Experiment satellite image sequences , 2001 .

[53]  Bernd Jähne,et al.  Quantitative analysis of NOx emissions from GOME-satellite image sequences , 2001 .

[54]  Roland Eils,et al.  Image Sequence Analysis to Investigate Dynamic Processes, Progress Report II, DFG Research Unit FOR240, 3/1998-2/2001 , 2000 .

[55]  A. Hahne,et al.  GOME-2 – Metop ’ s Second-Generation Sensor for Operational Ozone Monitoring , 2000 .

[56]  John P. Burrows,et al.  RING EFFECT: IMPACT OF ROTATIONAL RAMAN SCATTERING ON RADIATIVE TRANSFER IN EARTH’S ATMOSPHERE , 1998 .

[57]  K. Chance,et al.  Ring effect studies: Rayleigh scattering, including molecular parameters for rotational Raman scattering, and the Fraunhofer spectrum. , 1997, Applied optics.

[58]  Sanford Sillman,et al.  The sensitivity of ozone to nitrogen oxides and hydrocarbons in regional ozone episodes , 1990 .

[59]  Florence Goutail,et al.  O3 and NO2 ground‐based measurements by visible spectrometry during Arctic winter and spring 1988 , 1988 .

[60]  J. Grainger,et al.  Anomalous Fraunhofer Line Profiles , 1962, Nature.