Knowledge based decision making method for the selection of mixed refrigerant systems for energy efficient LNG processes

Mixed refrigerant (MR) systems are used in many industrial applications because of their high energy efficiency, compact design and energy-efficient heat transfer compared to other processes operating with pure refrigerants. The performance of MR systems depends strongly on the optimum refrigerant composition, which is difficult to obtain. This paper proposes a simple and practical method for selecting the appropriate refrigerant composition, which was inspired by (i) knowledge of the boiling point difference in MR components, and (ii) their specific refrigeration effect in bringing a MR system close to reversible operation. A feasibility plot and composite curves were used for full enforcement of the approach temperature. The proposed knowledge-based optimization approach was described and applied to a single MR and a propane precooled MR system for natural gas liquefaction. Maximization of the heat exchanger exergy efficiency was considered as the optimization objective to achieve an energy efficient design goal. Several case studies on single MR and propane precooled MR processes were performed to show the effectiveness of the proposed method. The application of the proposed method is not restricted to liquefiers, and can be applied to any refrigerator and cryogenic cooler where a MR is involved.

[1]  Tao Lu,et al.  Analysis and optimization of a cascading power cycle with liquefied natural gas (LNG) cold energy recovery , 2009 .

[2]  G. Venkatarathnam Cryogenic mixed refrigerant processes , 2008 .

[3]  Robin Smith,et al.  Optimal Synthesis of Mixed-Refrigerant Systems for Low-Temperature Processes , 2002 .

[4]  Sanggyu Lee,et al.  Optimization of single mixed refrigerant natural gas liquefaction plant with nonlinear programming , 2012 .

[5]  Tariq Shukri,et al.  LNG technology selection , 2004 .

[6]  Reinhard Radermacher,et al.  Performance enhancement of propane pre-cooled mixed refrigerant LNG plant , 2012 .

[7]  Xiongwen Xu,et al.  The correlation between mixed refrigerant composition and ambient conditions in the PRICO LNG process , 2013 .

[8]  G. P. Rangaiah,et al.  Inherent Safety Analysis of a Propane Precooled Gas-Phase Liquified Natural Gas Process , 2009 .

[9]  Mohd Shariq Khan,et al.  Design optimization of single mixed refrigerant natural gas liquefaction process using the particle swarm paradigm with nonlinear constraints , 2013 .

[10]  Ho-Myung Chang,et al.  Effect of multi-stream heat exchanger on performance of natural gas liquefaction with mixed refrigerant , 2012 .

[11]  D. Peng,et al.  A New Two-Constant Equation of State , 1976 .

[12]  Byung-Ik Lee,et al.  A generalized thermodynamic correlation based on three‐parameter corresponding states , 1975 .

[13]  J. M. Schultz The Polytropic Analysis of Centrifugal Compressors , 1962 .

[14]  Satish Kumar,et al.  LNG: An eco-friendly cryogenic fuel for sustainable development , 2011 .

[15]  Reinhard Radermacher,et al.  Optimization of propane pre-cooled mixed refrigerant LNG plant , 2011 .

[16]  Fusheng Chen,et al.  Performance of a single-stage Linde-Hampson refrigerator operating with binary refrigerants at the temperature level of −60 °C , 2010 .

[17]  Truls Gundersen,et al.  An Extended Pinch Analysis and Design procedure utilizing pressure based exergy for subambient cooling , 2007 .

[18]  Iftekhar A. Karimi,et al.  Operational modeling of multistream heat exchangers with phase changes , 2009 .

[19]  T. Gundersen,et al.  A liquefied energy chain for transport and utilization of natural gas for power production with CO2 capture and storage - Part 4: Sensitivity analysis of transport pressures and benchmarking with conventional technology for gas transport , 2009 .

[20]  Jian Zhang,et al.  Thermodynamic-Analysis-Based Energy Consumption Minimization for Natural Gas Liquefaction , 2011 .

[21]  Richard S. H. Mah,et al.  Interactive Synthesis of Cascade Refrigeration Systems , 1980 .

[22]  Luke E. K. Achenie,et al.  On the design of environmentally benign refrigerant mixtures : a mathematical programming approach , 1997 .

[23]  M. Babaelahi,et al.  Multi-objective optimization of a joule cycle for re-liquefaction of the Liquefied Natural Gas , 2011 .

[24]  A. K. Grezin,et al.  Efficient throttling cryogenic refrigerators which operate on mixtures , 1971 .

[25]  Xiang Wang,et al.  An optimal design methodology for large-scale gas liquefaction , 2012 .

[26]  Jian Zhang,et al.  Optimal design and operation of a C3MR refrigeration system for natural gas liquefaction , 2012, Comput. Chem. Eng..

[27]  M. Gong,et al.  Optimum composition calculation for multicomponent cryogenic mixture used in Joule-Thomson refrigerators , 2000 .

[28]  A. Aspelund,et al.  An optimization-simulation model for a simple LNG process , 2010, Comput. Chem. Eng..