Monitoring and Simulation of Mechanically Ventilated Underground Car Parks

Rapid motorization in developed and developing countries demands more parking spaces in urban areas. Underground car parking space in multi story buildings offers viable solution. However, lack of natural ventilation accumulates the harmful emissions from cars, operating in underground car parks. Exposure to these hazardous pollutants causes health risk to the users. Therefore, proper mechanical ventilation system should be adopted for the removal of harmful pollutants. This paper discusses the usage of modeling and simulation tools in the design of the mechanical ventilation system. Two widely used modeling techniques, multi-zone modeling and CFD modeling were used to simulate the contaminant distribution in a mechanical ventilated environment. The former provides an approximate macroscopic solution of the carbon monoxide (CO) distribution, while the later provides precise distribution of CO contours. The two models were validated against field measurements made at Chennai, India. The model predictions were very close to the actual site measurements. The impact of garage height and CO generation rate on ventilation requirement has been analysed

[1]  K. Matsushita,et al.  AN ENVIRONMENTAL STUDY OF UNDERGROUND PARKING LOT DEVELOPMENTS IN JAPAN , 1993 .

[2]  Wan Ki Chow,et al.  FIELD STUDY ON THE INDOOR THERMAL ENVIRONMENT AND CARBON MONOXIDE LEVELS IN A LARGE UNDERGROUND CAR PARK , 1996 .

[3]  K. Papakonstantinoua,et al.  Air quality in an underground garage : computational and experimental investigation of ventilation effectiveness , 2003 .

[4]  Moncef Krarti,et al.  Field evaluation of ventilation system performance in enclosed parking garages , 2000 .

[5]  James Axley Progress toward a general analytical method for predicting indoor air pollution in buildings- indoor air quality modeling phase III report , 1988 .

[6]  J. C. Ho,et al.  MODELLING OF HEAT AND CARBON MONOXIDE EMITTED FROM MOVING CARS IN AN UNDERGROUND CAR PARK , 2000 .

[7]  Wan Ki Chow,et al.  Personal Exposure to Carbon Monoxide in Underground Car Parks in Hong Kong , 1997 .

[8]  J. C. Ho,et al.  A field study on determination of carbon monoxide level and thermal environment in an underground car park , 2004 .

[9]  Moncef Krarti,et al.  Overview of existing regulations for ventilation requirements of enclosed vehicular parking facilities , 1999 .

[10]  N. C. Markatos,et al.  Numerical approach of carbon monoxide concentration dispersion in an enclosed garage , 2004 .

[11]  R. Xiang,et al.  Particulate pollution in an underground car park in Wuhan, China , 2013 .

[12]  Yu Wang,et al.  Numerical Study on Impulse Ventilation for Smoke Control in an Underground Car Park , 2011 .

[13]  Refrigerating ASHRAE handbook and product directory /published by the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc , 1977 .

[14]  Warren Mallon Occupational exposure limits , 2016 .

[15]  Nurul Izma Mohammed,et al.  Air Quality Profile in an Enclosed Car Park , 2014 .