Effectiveness of non-uniform thickness on a locking compression plate used as a biodegradable bone implant plate

Conventional locking compression plate (LCP) made of non-biodegradable materials are well-known bone implants for internal fracture fixation because of their proven experimental success. LCP, however, is mechanically underpowered when made up of biodegradable materials (even with Mg-alloy). The biodegradable implant plate should not only exhibit adequate mechanical performance during implantation but also perform well after fracture, at least until complete healing of the fractured bone. With the aim of achieving enhanced mechanical performance, the design of the LCP has been modified to the design of Biodegradable Locking Compression Plate (BLCP) by adding a suitable thickness in the middle (only 4.6% of the total volume of the LCP), which may help retain some additional strength during implantation and after degradation. Both BLCP and LCP have been comparatively analyzed via FEM with the aid of axial compression and four-point bending tests. BLCP has a better mechanical capability of withstanding loads in its degraded form than in its non-degradable form. Furthermore, BLCP is up to 15.83% mechanically better in the non-degraded form as compared to LCP, which again becomes up to 100% more mechanically adequate in the degraded forms of BLCP than in LCP. BLCP is found safe for degradation up to 2 mm or 6 months with an estimated degradation rate of 4 mm/year, which may allow it to support fractured bone for at least the standard healing time. BLCP can be considered as a superior biodegradable bone implant plate after experimental assurance with the physiological environment and may replace LCP.

[1]  G. Chandra,et al.  Effectiveness of laddered embossed structure in a locking compression plate for biodegradable orthopaedic implants , 2021, Journal of biomaterials applications.

[2]  G. Chandra,et al.  Longitudinally centered embossed structure in the locking compression plate for biodegradable bone implant plate: a finite element analysis , 2021, Computer methods in biomechanics and biomedical engineering.

[3]  G. Chandra,et al.  Design approaches and challenges for biodegradable bone implants: a review , 2021, Expert review of medical devices.

[4]  G. Chandra,et al.  Design and analysis of biodegradable buttress threaded screws for fracture fixation in orthopedics: a finite element analysis , 2021, Biomedical physics & engineering express.

[5]  Wei Zeng,et al.  Biomechanical evaluation of internal fixation implants for femoral neck fractures: A comparative finite element analysis , 2020, Comput. Methods Programs Biomed..

[6]  G. Chandra,et al.  Preparation Strategies for Mg-alloys for Biodegradable Orthopaedic Implants and Other Biomedical Applications: A Review , 2020 .

[7]  G. Chandra,et al.  Design of a biodegradable plate for femoral shaft fracture fixation. , 2020, Medical engineering & physics.

[8]  G. Chandra,et al.  Biodegradable bone implants in orthopedic applications: a review , 2020 .

[9]  A. Subramanian,et al.  Clinical complications of biodegradable screws for ligament injuries. , 2020, Materials science & engineering. C, Materials for biological applications.

[10]  C. Shuai,et al.  Mg bone implant: Features, developments and perspectives , 2020 .

[11]  Liangliang Cheng,et al.  Materials evolution of bone plates for internal fixation of bone fractures: A review , 2020, Journal of Materials Science & Technology.

[12]  Xiaochun Li,et al.  Orthopedic implants and devices for bone fractures and defects: Past, present and perspective , 2020 .

[13]  Ara Nazarian,et al.  Design of biodegradable, implantable devices towards clinical translation , 2019, Nature Reviews Materials.

[14]  Alessandro Ruggiero,et al.  Comparison of Meshing Strategies in THR Finite Element Modelling , 2019, Materials.

[15]  Naomichi Ogihara,et al.  Assessment of finite element models for prediction of osteoporotic fracture. , 2019, Journal of the mechanical behavior of biomedical materials.

[16]  Wen-xian Wang,et al.  Effect of nano-HA content on the mechanical properties, degradation and biocompatible behavior of Mg-Zn/HA composite prepared by spark plasma sintering , 2019, Materials Characterization.

[17]  Diego Mantovani,et al.  Current status and outlook on the clinical translation of biodegradable metals , 2019, Materials Today.

[18]  J. Bel Pitfalls and limits of locking plates. , 2019, Orthopaedics & traumatology, surgery & research : OTSR.

[19]  Yufeng Zheng,et al.  Optimizing mechanical property and cytocompatibility of the biodegradable Mg-Zn-Y-Nd alloy by hot extrusion and heat treatment , 2019, Journal of Materials Science & Technology.

[20]  Yuping Ren,et al.  Indirectly extruded biodegradable Zn-0.05wt%Mg alloy with improved strength and ductility: In vitro and in vivo studies , 2018, Journal of Materials Science & Technology.

[21]  P. Augat,et al.  Locking design affects the jamming of screws in locking plates. , 2018, Injury.

[22]  M. Koç,et al.  Review of magnesium-based biomaterials and their applications , 2018 .

[23]  R. S. Gill,et al.  Challenges and opportunities for biodegradable magnesium alloy implants , 2018 .

[24]  Stéphane Cotin,et al.  Real-Time Error Control for Surgical Simulation , 2016, IEEE Transactions on Biomedical Engineering.

[25]  Wei Li,et al.  The synergistic effect of trace Sr and Zr on the microstructure and properties of a biodegradable Mg-Zn-Zr-Sr alloy , 2017 .

[26]  Jie Luo,et al.  Effects of Zn concentration and heat treatment on the microstructure, mechanical properties and corrosion behavior of as-extruded Mg-Zn alloys produced by powder metallurgy , 2017 .

[27]  Y. Torres,et al.  Design, processing and characterization of titanium with radial graded porosity for bone implants , 2016 .

[28]  Yufeng Zheng,et al.  Microstructure, Mechanical Properties, Corrosion Behavior and Biocompatibility of As-Extruded Biodegradable Mg-3Sn-1Zn-0.5Mn Alloy , 2016 .

[29]  Frank Feyerabend,et al.  Mg and Mg alloys: how comparable are in vitro and in vivo corrosion rates? A review. , 2015, Acta biomaterialia.

[30]  Zhigang Xu,et al.  Recent advances on the development of magnesium alloys for biodegradable implants. , 2014, Acta biomaterialia.

[31]  C. Krettek,et al.  Intraprosthetic screw fixation increases primary fixation stability in periprosthetic fractures of the femur - a biomechanical study. , 2014, Medical engineering & physics.

[32]  E. Taheri,et al.  Biomechanical analysis of diversified screw arrangement on 11 holes locking compression plate considering time-varying properties of callus , 2014 .

[33]  David M. Andrews,et al.  Finite element modeling mesh quality, energy balance and validation methods: a review with recommendations associated with the modeling of bone tissue. , 2013, Journal of biomechanics.

[34]  Yangde Li,et al.  Microstructure, mechanical properties, in vitro degradation and cytotoxicity evaluations of Mg-1.5Y-1.2Zn-0.44Zr alloys for biodegradable metallic implants. , 2013, Materials science & engineering. C, Materials for biological applications.

[35]  G. Rouhi,et al.  A BRIEF INTRODUCTION INTO ORTHOPAEDIC IMPLANTS : SCREWS , PLATES , AND NAILS , 2013 .

[36]  Stephen J Ferguson,et al.  The influence of different osteosynthesis configurations with locking compression plates (LCP) on stability and fracture healing after an oblique 45° angle osteotomy. , 2012, Injury.

[37]  Seung-Hwan Chang,et al.  Finite element analysis using interfragmentary strain theory for the fracture healing process to which composite bone plates are applied , 2011 .

[38]  Alison C Jones,et al.  Periprosthetic fracture fixation of the femur following total hip arthroplasty: a review of biomechanical testing. , 2011, Clinical biomechanics.

[39]  Chaosuan Kanchanomai,et al.  Fatigue failure of an orthopedic implant – A locking compression plate , 2008 .

[40]  W. Montgomery,et al.  Orthopedic fixation devices. , 1991, Radiographics : a review publication of the Radiological Society of North America, Inc.

[41]  B. Anson,et al.  Measurements on the human femur - I. lengths, diameters and angles , 1941 .