Experimental study on dynamic behaviours of concrete after exposure to high temperatures up to 700 °C

A Split Hopkinson pressure bar were used to experimentally study the dynamic behaviours of normal-strength concrete after exposure to elevated temperatures up to 700 °C. The dynamic strength and stress–strain relation curves of fire-damaged concrete were measured to unveil the effects of high temperature and strain rate on the dynamic behaviours of fire-damaged concrete. Test results showed that fire-damaged concrete still experienced remarkable strain rate effect and the dynamic stress versus strain relations of fire-damaged concrete were significantly different from those of concrete at room temperature. There was no obvious effect of temperature and strain rate on the shape of the ascending branches of normalized stress–strain relation curves of concrete after exposure to high temperatures. The tested results also showed that high temperature and strain rate had remarkable effect on the dynamic increase factor (DIF) for the fire-damaged concrete. The effect of high temperature on DIF of the fire-damaged concrete decreased as the temperature increased. The tested results can be a basis for assessing the impact resistance and anti-collapse resistance of fire-damaged concrete structures.

[1]  Yan Xiao,et al.  Tests on impact behaviour of micro-concrete-filled steel tubes at elevated temperatures up to 400°C , 2009 .

[2]  D. Watstein Effect of Straining Rate on the Compressive Strength and Elastic Properties of Concrete , 1953 .

[3]  Comite Euro-International du Beton,et al.  CEB-FIP Model Code 1990 : design code , 1993 .

[4]  Y. Chen,et al.  Residual stress–strain relationship for concrete after exposure to high temperatures , 2006 .

[5]  W. Goldsmith,et al.  Dynamic behavior of concrete , 1966 .

[6]  Bernhard A. Schrefler,et al.  Numerical analysis of hygro-thermal behaviour and damage of concrete at high temperature , 1999 .

[7]  Y. N. Chan,et al.  Residual strength and pore structure of high-strength concrete and normal strength concrete after exposure to high temperatures , 1999 .

[8]  U. S. Lindholm Some experiments with the split hopkinson pressure bar , 1964 .

[9]  Parviz Soroushian,et al.  Dynamic Constitutive Behavior of Concrete , 1986 .

[10]  G. Gary,et al.  A Testing Technique of Confined Compression for Concrete at High Rates of Strain , 2007 .

[11]  Cheng Zhi,et al.  Measures of Strengthening Acceptance in “Code for Acceptance of Constructional Quality of Concrete Structures” GB50204-2002 , 2002 .

[12]  G. Gary,et al.  A testing technique for concrete under confinement at high rates of strain , 2008 .

[13]  O. Arioz Effects of elevated temperatures on properties of concrete , 2007 .

[14]  Jingsi Huo,et al.  Experimental Study on Dynamic Behavior of Concrete at Elevated Temperatures , 2011 .

[15]  S. H. Perry,et al.  Compressive behaviour of concrete at high strain rates , 1991 .

[16]  Yan Xiao,et al.  Effects of sustained axial load and cooling phase on post-fire behaviour of concrete-filled steel tubular stub columns , 2009 .

[17]  Patrice Bailly,et al.  Behaviour of a quasi-brittle material at high strain rate. Experiment and modelling , 2019 .

[18]  T. Lie,et al.  Residual Strength of Fire-Exposed Reinforced Concrete Columns , 1986 .

[19]  Qingming Li,et al.  About the dynamic strength enhancement of concrete-like materials in a split Hopkinson pressure bar test , 2003 .

[20]  B. Georgali,et al.  Microstructure of fire-damaged concrete. A case study , 2005 .

[21]  N. Carino,et al.  REVIEW OF MECHANICAL PROPERTIES OF HSC AT ELEVATED TEMPERATURE , 1998 .

[22]  Comite Euro-International du Beton,et al.  CEB-FIP Model Code 1990 , 1993 .

[23]  H. Kolsky An Investigation of the Mechanical Properties of Materials at very High Rates of Loading , 1949 .

[24]  Yunping Xi,et al.  Properties of Concrete After High-Temperature Heating and Cooling , 2008 .