Statistical analysis of the effect of dielectric barrier discharge (DBD) operating parameters on the surface processing of poly(methylmethacrylate) film

A dielectric barrier discharge (DBD) plasma, operating in air at atmospheric pressure, has been used to induce changes in the surface properties of poly(methylmethacrylate) (PMMA) films. The relative effects that key DBD operating parameters, specifically: discharge power, electrode gap and duration of exposure have on producing chemical and microstructural changes in the polymer surface region have been investigated. The approach taken involves the application of an orthogonal array experimental design and statistical analysis methodology. The various data sets obtained from these analyses have been used to develop an equation in which induced changes in the surface properties of the DBD modified PMMA films are expressed in terms of the effectiveness of the various processing parameters in producing them.In general, the results obtained clearly indicate that DBD plasma processing is an effective method for the controlled surface modification of PMMA. Relatively short exposures to the atmospheric pressure discharge produces a significant amount of oxygen incorporation at the surface as indicted by a pronounced reduction in water contact angle. Analysis of the role of each of the operating parameters concerned shows that they do indeed have selective effectiveness for inducing resultant surface modification. Duration of exposure to the DBD plasma, expressed here as the number of treatment cycles at a given speed of specimen transit through the electrode gap, was found to play a major role in decreasing the surface wettability of PMMA. Conversely, the magnitude of the discharge power was not a significant parameter in this regard. In contrast, the value of the applied power played the dominant role in achieving the observed enrichment of the surface oxygen abundance, as measured by XPS, with the duration of exposure to the discharge playing a secondary role in this case.The nature and scale of the induced surface changes that originate from the various processing conditions employed have been further considered to determine if an interrelationship exists between them. Non-parametric data analysis indicates that no significant correlation exists between the observed changes in measured polymer wettability and the attendant surface oxygen enrichment. This result suggests that the increase in surface wettability caused by DBD processing, as manifested in a reduced contact angle, is not merely attributable to changes in the surface chemistry. As such, it is postulated that changes in the surface microstructure may also contribute to this change in surface wettability.

[1]  N. Brown,et al.  Modification of the surface properties of a polypropylene (PP) film using an air dielectric barrier discharge plasma , 2002 .

[2]  R. Carman,et al.  Electron energy distribution functions for modelling the plasma kinetics in dielectric barrier discharges , 2000 .

[3]  C. Werner,et al.  Durable surface modification of poly(tetrafluoroethylene) by low pressure H2O plasma treatment followed by acrylic acid graft polymerization , 2002 .

[4]  B. Kasemo,et al.  Surface modification of spin-coated high-density polyethylene films by argon and oxygen glow discharge plasma treatments , 2002 .

[5]  M. Zeuner,et al.  Fundamental investigations in plasma modification of polymers , 1995 .

[6]  Jia-liang Zhang,et al.  Deposition of diamond-like carbon films by barrier discharge plasma with 1.4 and 20 kHz power sources , 2002 .

[7]  Young Ha Kim,et al.  Effect of poly(ethylene glycol) graft polymerization of poly(methyl methacrylate) on cell adhesion: In vitro and in vivo study , 2001, Journal of cataract and refractive surgery.

[8]  Choon-Gi Choi,et al.  Effect of fluorine plasma treatment on PMMA and their application to passive optical waveguides. , 2003, Journal of colloid and interface science.

[9]  Junying Chen,et al.  Plasma-surface modification of biomaterials , 2002 .

[10]  K. Neoh,et al.  Plasma-induced graft polymerization of poly(ethylene glycol) methyl ether methacrylate on poly(tetrafluoroethylene) films for reduction in protein adsorption , 2002 .

[11]  D. Dixon,et al.  The effect of an air-dielectric barrier discharge on the surface properties and peel strength of medical packaging materials , 2004 .

[12]  C. Werner,et al.  Stability and ageing of plasma treated poly(tetrafluoroethylene) surfaces , 2002 .

[13]  Lih-Yuan Deng,et al.  Orthogonal Arrays: Theory and Applications , 1999, Technometrics.

[14]  L. Gerenser,et al.  Plasma Treatment of Polymers , 2003 .

[15]  A. Bogaerts,et al.  Gas discharge plasmas and their applications , 2002 .

[16]  M. Zeuner,et al.  Plasma diagnostics for surface modification of polymers , 1998 .

[17]  H. Biederman RF sputtering of polymers and its potential application , 2000 .

[18]  R. Mota,et al.  Surface energy increase of oxygen-plasma-treated PET , 2003 .

[19]  C. Kao,et al.  Plasma-induced grafted polymerization of acrylic acid and subsequent grafting of collagen onto polymer film as biomaterials. , 1996, Biomaterials.

[20]  G. Oehrlein Surface processes in low pressure plasmas , 1997 .

[21]  T. Joyce,et al.  Statistical wear analysis of PA-6/UHMWPE alloy, UHMWPE and PA-6 , 2001 .

[22]  S. Ishikawa,et al.  Surface Modification of Poly(tetrafluoroethylene) Film Using Dielectric Barrier Discharge of Intermittent Pulse Voltage , 2000 .

[23]  L. Ren,et al.  Abrasive wear behavior of particle reinforced ultrahigh molecular weight polyethylene composites , 1999 .

[24]  H. Kaczmarek,et al.  Surface modification of thin polymeric films by air-plasma or UV-irradiation , 2002 .

[25]  Yoshito Ikada,et al.  Adhesion and Bonding in Composites , 1989 .

[26]  Maurice Romand,et al.  Surface modification of polyimide using dielectric barrier discharge treatment , 2001 .

[27]  Giovanni Dietler,et al.  Interaction of low-energy ions (< 10 eV) with polymethylmethacrylate during plasma treatment , 1995 .

[28]  T. Chandy,et al.  Use of plasma glow for surface-engineering biomolecules to enhance bloodcompatibility of Dacron and PTFE vascular prosthesis. , 2000, Biomaterials.

[29]  Sang Kyoo Lim,et al.  Surface modification of ethylene‐co‐tetrafluoroethylene films by remote plasmas , 2002 .

[30]  M. Zeuner,et al.  Rf magnetron sputtering of polytetrafluoroethylene under various conditions , 2001 .

[31]  J. Q. Wu,et al.  Comparative study on the effect of RF and DBD plasma treatment on PTFE surface modification , 2004 .

[32]  Y. Bao,et al.  The influence of process parameters on the degradation of thermally sprayed polymer coatings , 1997 .

[33]  Chaozong Liu,et al.  Effects of DBD plasma operating parameters on the polymer surface modification , 2004 .

[34]  K. L. Tan,et al.  Plasma-induced immobilization of poly(ethylene glycol) onto poly(vinylidene fluoride) microporous membrane , 2002 .

[35]  M. Zeuner,et al.  Ion energy distributions in oxygen and argon in a pulsed mode RF discharge , 1997 .

[36]  J. Tong,et al.  Surface modification of PTFE by plasma treatment , 2000 .