Blend uniformity end-point determination using near-infrared spectroscopy and multivariate calibration.

A multivariate calibration approach using near-infrared (NIR) spectroscopy for determining blend uniformity end-point of a pharmaceutical solid dosage form containing 29.4% (w/w) drug load with three major excipients (crospovidone, lactose, and microcrystalline cellulose) is presented. A set of 21 off-line, static calibration samples were used to develop a multivariate partial least-squares (PLS) calibration model for on-line predictions of the API content during the blending process. The concentrations of the API and the three major excipients were varied randomly to minimize correlations between the components. A micro-electrical-mechanical-system (MEMS) based NIR spectrometer was used for this study. To minimize spectral differences between the static and dynamic measurement modes, the acquired NIR spectra were preprocessed using standard normal variate (SNV) followed by second derivative Savitsky-Golay using 21 points. The performance of the off-line PLS calibration model were evaluated in real-time on 67 production scale (750L bin size) blend experiments conducted over 3 years. The real-time API-NIR (%) predictions of all batches ranged from 93.7% to 104.8% with standard deviation ranging from 0.5% to 1.8%. These results showed the attainment of blend homogeneity and were confirmed with content uniformity by HPLC of respective manufactured tablets values ranging from 95.4% to 101.3% with standard deviation ranging from 0.5% to 2.1%. Furthermore, the performance of the PLS calibration model was evaluated against off-target batches manufactured with high and low amounts of water during the granulation phase of production. This approach affects the particle size and hence blending. All the off-target batches exhibited API-NIR (%) predictions of 94.6% to 103.5% with standard deviation ranging from 0.7% to 1.9%. Using off-target data, a systematic approach was developed to determine blend uniformity end-point. This was confirmed with 3 production scale batches whereby the blend uniformity end-point was determined using the PLS calibration model. Subsequently, the uniformity was also ascertained with conventional thief sampling followed by HPLC analysis and content uniformity by HPLC of the manufactured tablets.

[1]  E. Sevick-Muraca,et al.  Measurement of low-dose active pharmaceutical ingredient in a pharmaceutical blend using frequency-domain photon migration. , 2004, Journal of pharmaceutical sciences.

[2]  Rosario LoBrutto,et al.  Content uniformity determination of pharmaceutical tablets using five near-infrared reflectance spectrometers: a process analytical technology (PAT) approach using robust multivariate calibration transfer algorithms. , 2008, Analytica chimica acta.

[3]  Thomas P. Garcia,et al.  A solid dosage and blend content uniformity troubleshooting diagram , 2001 .

[4]  Weiyong. Li,et al.  The effect of beam size on real-time determination of powder blend homogeneity by an online near infrared sensor. , 2007, Journal of pharmaceutical and biomedical analysis.

[5]  D. T. Witte,et al.  Simple assessment of homogeneity in pharmaceutical mixing processes using a near-infrared reflectance probe and control charts. , 2006, Journal of pharmaceutical and biomedical analysis.

[6]  P. K. Aldridge,et al.  On-line monitoring of powder blend homogeneity by near-infrared spectroscopy. , 1996, Analytical chemistry.

[7]  Weiyong. Li,et al.  Mass-balanced blend uniformity analysis of pharmaceutical powders by at-line near-infrared spectroscopy with a fiber-optic probe. , 2006, International journal of pharmaceutics.

[8]  J. Drennen,et al.  Near-infrared spectroscopic characterization of pharmaceutical powder blends. , 1996, Journal of pharmaceutical and biomedical analysis.

[9]  C R Gonzales,et al.  Blend uniformity analysis: validation and in-process testing. Technical Report No. 25. PDA (Parenteral Drug association). , 1997, PDA journal of pharmaceutical science and technology.

[10]  Yusuf Sulub,et al.  Near-infrared multivariate calibration updating using placebo: A content uniformity determination of pharmaceutical tablets , 2008 .

[11]  J. Drennen,et al.  A Process Analytical Technology approach to near-infrared process control of pharmaceutical powder blending. Part III: Quantitative near-infrared calibration for prediction of blend homogeneity and characterization of powder mixing kinetics. , 2006, Journal of pharmaceutical sciences.

[12]  James K Drennen,et al.  A Process Analytical Technology approach to near-infrared process control of pharmaceutical powder blending. Part I: D-optimal design for characterization of powder mixing and preliminary spectral data evaluation. , 2006, Journal of pharmaceutical sciences.

[13]  Fernando Muzzio,et al.  A Homogeneity Study Using NIR Spectroscopy: Tracking Magnesium Stearate in Bohle Bin-Blender , 2003, Drug development and industrial pharmacy.

[14]  Zhenqi Shi,et al.  Process characterization of powder blending by near-infrared spectroscopy: blend end-points and beyond. , 2008, Journal of pharmaceutical and biomedical analysis.

[15]  L. Danielsson,et al.  Quantitative in-line monitoring of powder blending by near infrared reflection spectroscopy , 2002 .

[16]  James K Drennen,et al.  A Process Analytical Technology approach to near-infrared process control of pharmaceutical powder blending: Part II: Qualitative near-infrared models for prediction of blend homogeneity. , 2006, Journal of pharmaceutical sciences.

[17]  S. Sekulic,et al.  Automated system for the on-line monitoring of powder blending processes using near-infrared spectroscopy. Part II. Qualitative approaches to blend evaluation. , 1998, Journal of pharmaceutical and biomedical analysis.

[18]  Abhay Gupta,et al.  Real-time on-line blend uniformity monitoring using near-infrared reflectance spectrometry: a noninvasive off-line calibration approach. , 2009, Journal of pharmaceutical and biomedical analysis.