Short-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables

The application of high-power voltage-source converters (VSCs) to multiterminal dc networks is attracting research interest. The development of VSC-based dc networks is constrained by the lack of operational experience, the immaturity of appropriate protective devices, and the lack of appropriate fault analysis techniques. VSCs are vulnerable to dc-cable short-circuit and ground faults due to the high discharge current from the dc-link capacitance. However, faults occurring along the interconnecting dc cables are most likely to threaten system operation. In this paper, cable faults in VSC-based dc networks are analyzed in detail with the identification and definition of the most serious stages of the fault that need to be avoided. A fault location method is proposed because this is a prerequisite for an effective design of a fault protection scheme. It is demonstrated that it is relatively easy to evaluate the distance to a short-circuit fault using voltage reference comparison. For the more difficult challenge of locating ground faults, a method of estimating both the ground resistance and the distance to the fault is proposed by analyzing the initial stage of the fault transient. Analysis of the proposed method is provided and is based on simulation results, with a range of fault resistances, distances, and operational conditions considered.

[1]  Seung-Jae Lee,et al.  Fault Location for Underground Power Cable Using Distributed Parameter Approach , 2008, IEEE Transactions on Power Systems.

[2]  Bin Lu,et al.  A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters , 2008, 2008 IEEE Industry Applications Society Annual Meeting.

[3]  A. Sannino,et al.  Protection of Low-Voltage DC Microgrids , 2009, IEEE Transactions on Power Delivery.

[4]  Thierry Meynard,et al.  Survey on Fault Operation on Multilevel Inverters , 2010, IEEE Transactions on Industrial Electronics.

[5]  Seung-Jae Lee,et al.  A new fault location algorithm using direct circuit analysis for distribution systems , 2004, IEEE Transactions on Power Delivery.

[6]  J.C. McCall,et al.  Overcurrent protection of capacitors applied on industrial distribution systems , 1991, Conference Record of the 1991 IEEE Industry Applications Society Annual Meeting.

[7]  Fang Zheng Peng,et al.  Multilevel inverters: a survey of topologies, controls, and applications , 2002, IEEE Trans. Ind. Electron..

[8]  Mesut Baran,et al.  DC distribution for industrial systems: opportunities and challenges , 2002, IEEE Technical Conference Industrial and Commerical Power Systems.

[9]  Leopoldo García Franquelo,et al.  Modeling Strategy for Back-to-Back Three-Level Converters Applied to High-Power Wind Turbines , 2006, IEEE Transactions on Industrial Electronics.

[10]  Narain G. Hingorani Transient Overvoltage on a Bipolar HVDC Overhead Line Caused by DC Line Faults , 1970 .

[11]  K.L. Butler-Purry,et al.  A Novel Condition Assessment System for Underground Distribution Applications , 2010, IEEE Transactions on Power Systems.

[12]  Paul M. Anderson Power System Protection , 1998 .

[13]  O.P. Malik,et al.  Hybrid Traveling Wave/Boundary Protection for Monopolar HVDC Line , 2009, IEEE Transactions on Power Delivery.

[14]  Frede Blaabjerg,et al.  A New Low-Cost, Fully Fault Protected PWM-VSI Inverter with True Phase-Current Information , 1995 .

[15]  Boon-Teck Ooi,et al.  Locating and Isolating DC Faults in Multi-Terminal DC Systems , 2007, IEEE Transactions on Power Delivery.

[16]  F. M. Hughes,et al.  Fault ride through of fully rated converter wind turbines with AC and DC transmission systems , 2009 .

[17]  R. S. Thallam,et al.  Transient overvoltages on a three terminal DC transmission system due to monopolar ground faults , 1990 .

[18]  Bin Wu,et al.  Recent Advances and Industrial Applications of Multilevel Converters , 2010, IEEE Transactions on Industrial Electronics.

[19]  E. W. Kimbark,et al.  Transient Overvoltages Caused by Monopolar Ground Fault on Bipolar DC Line: Theory and Simulation , 1970 .

[20]  Seung-Ki Sul,et al.  A New Architecture for Offshore Wind Farms , 2008, IEEE Transactions on Power Electronics.

[21]  John E. Fletcher,et al.  Protection scheme design for meshed VSC-HVDC transmission systems of large-scale wind farms , 2010 .

[22]  D. Boroyevich,et al.  Failure-Mode Analysis and Protection of Three-Level Neutral-Point-Clamped PWM Voltage Source Converters , 2010, IEEE Transactions on Industry Applications.

[23]  S. Sugimoto,et al.  Protection scheme of voltage sourced converters based HVDC system under DC fault , 2002, IEEE/PES Transmission and Distribution Conference and Exhibition.

[24]  P. Cartwright,et al.  VSC transmission operating under unbalanced AC conditions - analysis and control design , 2005, IEEE Transactions on Power Delivery.

[25]  W.L. Kling,et al.  HVDC Connection of Offshore Wind Farms to the Transmission System , 2007, IEEE Transactions on Energy Conversion.

[26]  Sang-Hee Kang,et al.  Fault Location Algorithm Based on Cross Correlation Method for HVDC Cable Lines , 2008 .

[27]  M.E. Baran,et al.  Overcurrent Protection on Voltage-Source-Converter-Based Multiterminal DC Distribution Systems , 2007, IEEE Transactions on Power Delivery.

[28]  Jin Yang,et al.  Multiterminal DC Wind Farm Collection Grid Internal Fault Analysis and Protection Design , 2010, IEEE Transactions on Power Delivery.

[29]  E. C. Bascom,et al.  Computerized underground cable fault location expertise , 1994, Proceedings of IEEE/PES Transmission and Distribution Conference.

[30]  Y. Jiang-Hafner,et al.  On the short circuit current contribution of HVDC Light , 2002, IEEE/PES Transmission and Distribution Conference and Exhibition.

[31]  Boon-Teck Ooi,et al.  Protection of VSC-multi-terminal HVDC against DC faults , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[32]  Om P. Malik,et al.  Correction to “Hybrid Traveling Wave/Boundary Protection for Monopolar HVDC Line” [Apr 09 569-578] , 2009 .