Rapid droplet mixers for digital microfluidic systems.

The mixing of analytes and reagents for a biological or chemical lab-on-a-chip is an important, yet difficult, microfluidic operation. As volumes approach the sub-nanoliter regime, the mixing of liquids is hindered by laminar flow conditions. An electrowetting-based linear-array droplet mixer has previously been reported. However, fixed geometric parameters and the presence of flow reversibility have prevented even faster droplet mixing times. In this paper, we study the effects of varying droplet aspect ratios (height:diameter) on linear-array droplet mixers, and propose mixing strategies applicable for both high and low aspect ratio systems. An optimal aspect ratio for four electrode linear-array mixing was found to be 0.4, with a mixing time of 4.6 seconds. Mixing times were further reduced at this ratio to less than three seconds using a two-dimensional array mixer, which eliminates the effects of flow reversibility. For lower aspect ratio (</=0.2) systems, we present a split-and-merge mixer that takes advantage of the ability to perform droplet splitting at these ratios, resulting in a mixing time of less than two seconds.

[1]  T. Fujii,et al.  Handling of Picoliter Liquid Samples in a Poly(dimethylsiloxane)-Based Microfluidic Device , 1999 .

[2]  R. Fair,et al.  A digital microfluidic biosensor for multianalyte detection , 2003, The Sixteenth Annual International Conference on Micro Electro Mechanical Systems, 2003. MEMS-03 Kyoto. IEEE.

[3]  Joseph A. Izatt,et al.  3-D IMAGING OF MOVING DROPLETS FOR MICROFLUIDICS USING OPTICAL COHERENCE TOMOGRAPHY , 2003 .

[4]  C. Kim,et al.  Enhancement of mixing by droplet-based microfluidics , 2002, Technical Digest. MEMS 2002 IEEE International Conference. Fifteenth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.02CH37266).

[5]  R. Fair,et al.  Design and testing of an interpolating mixing architecture for electrowetting-based droplet-on-chip chemical dilution , 2003, TRANSDUCERS '03. 12th International Conference on Solid-State Sensors, Actuators and Microsystems. Digest of Technical Papers (Cat. No.03TH8664).

[6]  Phil Paik,et al.  Electrowetting-based droplet mixers for microfluidic systems. , 2003, Lab on a chip.

[7]  Brian N. Johnson,et al.  An integrated nanoliter DNA analysis device. , 1998, Science.

[8]  M. Washizu Electrostatic actuation of liquid droplets for micro-reactor applications , 1997 .

[9]  R. Fair,et al.  Electrowetting-based actuation of liquid droplets for microfluidic applications , 2000 .

[10]  Richard B. Fair,et al.  Microfluidic electrowetting-based droplet mixing , 2001, 2001 Microelectromechanical Systems Conference (Cat. No. 01EX521).

[11]  M. Washizu,et al.  Electrostatic actuation of liquid droplets for micro-reactor applications , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.

[12]  R. Fair,et al.  Electrowetting-based actuation of droplets for integrated microfluidics. , 2002, Lab on a chip.

[13]  T. Jones,et al.  Dielectrophoretic liquid actuation and nanodroplet formation , 2001 .

[14]  C. Kim,et al.  Electrowetting and electrowetting-on-dielectric for microscale liquid handling , 2002 .

[15]  S. Cho,et al.  Creating, transporting, cutting, and merging liquid droplets by electrowetting-based actuation for digital microfluidic circuits , 2003 .