Confocal microwave imaging for breast cancer detection: localization of tumors in three dimensions

The physical basis for breast tumor detection with microwave imaging is the contrast in dielectric properties of normal and malignant breast tissues. Confocal microwave imaging involves illuminating the breast with an ultra-wideband pulse from a number of antenna locations, then synthetically focusing reflections from the breast. The detection of malignant tumors is achieved by the coherent addition of returns from these strongly scattering objects. In this paper, we demonstrate the feasibility of detecting and localizing small (<1 cm) tumors in three dimensions with numerical models of two system configurations involving synthetic cylindrical and planar antenna arrays. Image formation algorithms are developed to enhance tumor responses and reduce early- and late-time clutter. The early-time clutter consists of the incident pulse and reflections from the skin, while the late-time clutter is primarily due to the heterogeneity of breast tissue. Successful detection of 6-mm-diameter spherical tumors is achieved with both planar and cylindrical systems, and similar performance measures are obtained. The influences of the synthetic array size and position relative to the tumor are also explored.

[1]  Allen Taflove,et al.  Computational Electrodynamics the Finite-Difference Time-Domain Method , 1995 .

[2]  J. E. Bridges,et al.  Wideband ultralow reverberation antenna for biological sensing , 1997 .

[3]  A. W. Preece,et al.  FDTD analysis of a non-invasive sensor for the detection of breast tumours , 1994, 1994 IEEE MTT-S International Microwave Symposium Digest (Cat. No.94CH3389-4).

[4]  A. Taflove,et al.  Two-dimensional FDTD analysis of a pulsed microwave confocal system for breast cancer detection: fixed-focus and antenna-array sensors , 1998, IEEE Transactions on Biomedical Engineering.

[5]  Paul M. Meaney,et al.  Nonactive antenna compensation for fixed-array microwave imaging. II. Imaging results , 1999, IEEE Transactions on Medical Imaging.

[6]  Heywang-Köbrunner Sh,et al.  Nonmammographic breast imaging techniques. , 1992 .

[7]  Robert H. Svenson,et al.  Microwave tomography: a two-dimensional Newton iterative scheme , 1998 .

[8]  Stuchly,et al.  Dielectric properties of breast carcinoma and the surrounding tissues , 1988, IEEE Transactions on Biomedical Engineering.

[9]  P. Huynh,et al.  The false-negative mammogram. , 1998, Radiographics : a review publication of the Radiological Society of North America, Inc.

[10]  M. Säbel,et al.  Recent developments in breast imaging. , 1996, Physics in medicine and biology.

[11]  S. S. Chaudhary,et al.  Dielectric properties of normal & malignant human breast tissues at radiowave & microwave frequencies. , 1984, Indian journal of biochemistry & biophysics.

[12]  Elise C. Fear,et al.  Microwave detection of breast cancer , 2000 .

[13]  Mario Bertero,et al.  Image restoration in chirp-pulse microwave CT (CP-MCT) , 2000, IEEE Transactions on Biomedical Engineering.

[14]  Paul M. Meaney,et al.  A clinical prototype for active microwave imaging of the breast , 2000 .

[15]  J. Elmore,et al.  Ten-year risk of false positive screening mammograms and clinical breast examinations. , 1998, The New England journal of medicine.

[16]  S.C. Hagness,et al.  A confocal microwave imaging algorithm for breast cancer detection , 2001, IEEE Microwave and Wireless Components Letters.

[17]  E A Sickles,et al.  Screening mammography in community practice: positive predictive value of abnormal findings and yield of follow-up diagnostic procedures. , 1995, AJR. American journal of roentgenology.

[18]  Jean-Pierre Berenger,et al.  A perfectly matched layer for the absorption of electromagnetic waves , 1994 .

[19]  W. Joines,et al.  The measured electrical properties of normal and malignant human tissues from 50 to 900 MHz. , 1994, Medical physics.

[20]  A. Taflove,et al.  Three-dimensional FDTD analysis of a pulsed microwave confocal system for breast cancer detection: design of an antenna-array element , 1999 .

[21]  R. J. Joseph,et al.  Advances in Computational Electrodynamics: The Finite - Di erence Time - Domain Method , 1998 .

[22]  S H Heywang-Köbrunner,et al.  Nonmammographic breast imaging techniques. , 1992, Current opinion in radiology.

[23]  Elise C. Fear,et al.  Microwave detection of breast tumors: comparison of skin subtraction algorithms , 2000, SPIE Optics + Photonics.

[24]  R. Hendrick,et al.  Imaging of the radiographically dense breast. , 1993, Radiology.

[25]  David J. Daniels,et al.  Surface-Penetrating Radar , 1996 .

[26]  Elise C. Fear,et al.  Microwave system for breast tumor detection , 1999 .

[27]  Martin P. Robinson,et al.  Dielectric imaging for localisation and detection of breast tumours , 1993, 1993 IEEE MTT-S International Microwave Symposium Digest.

[28]  Matteo Pastorino,et al.  Reconstruction of dielectric permittivity distributions in arbitrary 2-D inhomogeneous biological bodies by a multiview microwave numerical method , 1993, IEEE Trans. Medical Imaging.

[29]  Ann Franchois,et al.  Quantitative microwave imaging with a 2.45-GHz planar microwave camera , 1998, IEEE Transactions on Medical Imaging.