A simple but precise method for quantitative measurement of the quality of the laser focus in a scanning optical microscope

We report a method for characterizing the focussing laser beam exiting the objective in a laser scanning microscope. This method provides the size of the optical focus, the divergence of the beam, the ellipticity and the astigmatism. We use a microscopic‐scale knife edge in the form of a simple transmission electron microscopy grid attached to a glass microscope slide, and a light‐collecting optical fibre and photodiode underneath the specimen. By scanning the laser spot from a reflective to a transmitting part of the grid, a beam profile in the form of an error function can be obtained and by repeating this with the knife edge at different axial positions relative to the beam waist, the divergence and astigmatism of the postobjective laser beam can be obtained. The measured divergence can be used to quantify how much of the full numerical aperture of the lens is used in practice. We present data of the beam radius, beam divergence, ellipticity and astigmatism obtained with low (0.15, 0.7) and high (1.3) numerical aperture lenses and lasers commonly used in confocal and multiphoton laser scanning microscopy. Our knife‐edge method has several advantages over alternative knife‐edge methods used in microscopy including that the knife edge is easy to prepare, that the beam can be characterized also directly under a cover slip, as necessary to reduce spherical aberrations for objectives designed to be used with a cover slip, and it is suitable for use with commercial laser scanning microscopes where access to the laser beam can be limited.

[1]  E. Abbe,et al.  Note on the Proper Definition of the Amplifying Power of a Lens or Lens‐system , 1884 .

[2]  P. Sheng,et al.  Knife-edge scanning measurements of subwavelength focused light beams. , 1977, Applied optics.

[3]  W. Webb,et al.  Measurement of submicron laser beam radii. , 1981, Applied optics.

[4]  Donald K. Cohen,et al.  Techniques for measuring 1-μm diam Gaussian beams , 1984 .

[5]  T. S. Gardner,et al.  Measurement of 1-μm diam beams , 1986 .

[6]  S. Nemoto,et al.  Nonparaxial Gaussian beams. , 1990, Applied optics.

[7]  Anthony E. Siegman,et al.  Choice of clip levels for beam width measurements using knife-edge techniques , 1991 .

[8]  S Inoué,et al.  Image sharpness and contrast transfer in coherent confocal microscopy , 1993, Journal of microscopy.

[9]  D. Richter,et al.  Construction and performance of a custom-built two-photon laser scanning system , 2003 .

[10]  C. Sheppard,et al.  Practical limits of resolution in confocal and non‐linear microscopy , 2004, Microscopy research and technique.

[11]  The M2 factor of nonparaxial Hermite-Gaussian beams and related problems , 2005 .

[12]  Robert M Zucker,et al.  Evaluation of confocal microscopy system performance. , 2001, Methods in molecular biology.

[13]  An automated submicron beam profiler for characterization of high numerical aperture optics. , 2008, The Review of scientific instruments.

[14]  F. He,et al.  Extension of imaging depth in two‐photon fluorescence microscopy using a long‐wavelength high‐pulse‐energy femtosecond laser source , 2011, Journal of microscopy.

[15]  Erlangen,et al.  Interaction of highly focused vector beams with a metal knife-edge. , 2011, Optics Express.

[16]  Andreas T. Schaefer,et al.  Two-photon calcium imaging of evoked activity from L5 somatosensory neurons in vivo , 2011, Nature Neuroscience.

[17]  Xiangsheng Xie,et al.  Three-dimensional measurement of a tightly focused laser beam , 2013 .

[18]  G. Leuchs,et al.  Corrections to the knife-edge based reconstruction scheme of tightly focused light beams. , 2013, Optics express.