Effects of malalignment angle on the contact stress of knee prosthesis components, using finite element method.

In this paper, the complex 3D virtual model of the prosthetic knee is obtained using embedded applications: DesignModeler and SpaceClaim under ANSYS Workbench 14.5 software package. A number of six cases of prosthetic knee joint assembly, depending on the malalignment angle, are developed. Stress maps and the values of the maximum von Mises stress on the three prosthesis components: polyethylene insert, tibial component and femoral component, for all studied prosthetic knee assemblies were obtained. The results show that as the malalignment angle increases, the values of von Mises stresses increase in all prosthesis components. The parameterized virtual models of the knee prosthesis components allow different changes in shape or dimensions, which can lead to the optimization of the implant and to the improvement of the prosthetic knee biomechanics.

[1]  Daniela Tarniţă,et al.  Experimental measurement of flexion-extension movement in normal and osteoarthritic human knee. , 2013, Romanian journal of morphology and embryology = Revue roumaine de morphologie et embryologie.

[2]  D S Barrett,et al.  Explicit Finite Element Simulation of Eccentric Loading in Total Knee Replacement , 2003, Clinical orthopaedics and related research.

[3]  Daniela Tarnita,et al.  Modular adaptive bone plate connected by Nitinol staple , 2010 .

[4]  R E Jensen,et al.  A comparison of contact pressures in tibial and patellar total knee components before and after service in vivo. , 1994, Clinical orthopaedics and related research.

[5]  J J Collins,et al.  The redundant nature of locomotor optimization laws. , 1995, Journal of biomechanics.

[6]  Marco Viceconti,et al.  Subject-specific finite element models can accurately predict strain levels in long bones. , 2007, Journal of biomechanics.

[7]  Cătălin Alexandru Optimal Design of the Mechanical Systems Using Parametric Technique & MBS (Multi-Body Systems) Software , 2012 .

[8]  Markus Kuster,et al.  Joint Load Considerations In Total Knee Replacement , 1997 .

[9]  Daniela TarniŢă,et al.  Wearable sensors used for human gait analysis. , 2016, Romanian journal of morphology and embryology = Revue roumaine de morphologie et embryologie.

[10]  Daniela Tarniţă,et al.  Modular adaptive bone plate for humerus bone osteosynthesis. , 2009, Romanian journal of morphology and embryology = Revue roumaine de morphologie et embryologie.

[11]  N. Yang The effect of the frontal plane tibiofemoral angle on the contact stress and strain at the knee joint , 2009 .

[12]  Jason P. Halloran,et al.  Explicit finite element modeling of total knee replacement mechanics. , 2005, Journal of biomechanics.

[13]  P S Walker,et al.  A computational model for the prediction of total knee replacement kinematics in the sagittal plane. , 2000, Journal of biomechanics.

[14]  Dan Tarnita,et al.  Development of a Three-Dimensional Finite Element Knee Prosthesis Model , 2016 .

[15]  Daniela Tarnita,et al.  Influences of Varus Tilt on the Stresses in Human Prosthetic Knee Joint , 2016 .

[16]  D. Tarniță,et al.  Orthopaedic Modular Implants Based on Shape Memory Alloys , 2011 .

[17]  J M T Penrose,et al.  Development of An Accurate Three-dimensional Finite Element Knee Model , 2002, Computer methods in biomechanics and biomedical engineering.

[18]  Nicolae Dumitru,et al.  Dynamic Analysis of an Exoskeleton New Ankle Joint Mechanism , 2015 .

[19]  Walker Ps Requirements for successful total knee replacements. Design considerations. , 1989 .

[20]  R J Jefferson,et al.  The Role of the Quadriceps in Controlling Impulsive Forces around Heel Strike , 1990, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[21]  J. Liau,et al.  The effect of malalignment on stresses in polyethylene component of total knee prostheses--a finite element analysis. , 2002, Clinical biomechanics.

[22]  Doina Pisla,et al.  Kinematics and Design of a 5-DOF Parallel Robot Used in Minimally Invasive Surgery , 2010 .

[23]  M Beaugonin,et al.  Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis. , 2002, Journal of biomechanics.

[24]  O. Harrysson,et al.  Custom-designed orthopedic implants evaluated using finite element analysis of patient-specific computed tomography data: femoral-component case study , 2007, BMC musculoskeletal disorders.

[25]  Francesco Migliavacca,et al.  Contact stresses and fatigue life in a knee prosthesis: comparison between in vitro measurements and computational simulations. , 2004, Journal of biomechanics.

[26]  B. Gherman,et al.  ON WORKSPACE AND ACCURACY EVALUATION OF A PARALLEL ROBOT FOR NEEDLE PLACEMENT PROCEDURES , 2016 .

[27]  Roxana M. Tarnita,et al.  Numerical simulations of human tibia osteosynthesis using modular plates based on Nitinol staples. , 2010, Romanian journal of morphology and embryology = Revue roumaine de morphologie et embryologie.

[28]  J. Szivek,et al.  Average and peak contact stress distribution evaluation of total knee arthroplasties. , 1996, The Journal of arthroplasty.

[29]  R. S. Yang,et al.  Contact stress on polyethylene components of a new rotating hinge with a spherical contact surface. , 2001, Clinical biomechanics.

[30]  D. Tarniță,et al.  Contributions on the dynamic simulation of the virtual model of the human knee joint , 2009 .

[31]  Ionut Geonea,et al.  Design and Simulation of a Single DOF Human-Like Leg Mechanism , 2013 .

[32]  Daniela Tarnita,et al.  Contributions on the Modeling and Simulation of the Human Knee Joint with Applications to the Robotic Structures , 2014 .

[33]  Ligia Rusu,et al.  The three-dimensional modeling of the complex virtual human elbow joint. , 2010, Romanian journal of morphology and embryology = Revue roumaine de morphologie et embryologie.

[34]  J. Simões,et al.  Experimental validation of intact and implanted distal femur finite element models. , 2007, Journal of biomechanics.

[35]  L. Daza,et al.  Analysis, Simulation And Prediction Of ContactStresses In Articular Cartilage Of The Knee Joint , 2007 .

[36]  R. E. Jensen,et al.  Analysis of the Failure of 122 Polyethylene Inserts From Uncemented Tibial Knee Components , 1991, Clinical orthopaedics and related research.

[37]  J B Morrison,et al.  The mechanics of the knee joint in relation to normal walking. , 1970, Journal of biomechanics.

[38]  Insu Jeon,et al.  Biomechanical analysis of the effects of medial meniscectomy on degenerative osteoarthritis , 2011, Medical & Biological Engineering & Computing.

[39]  M. Hull,et al.  A finite element model of the human knee joint for the study of tibio-femoral contact. , 2002, Journal of biomechanical engineering.

[40]  Martin Kubíček,et al.  STRESS STRAIN ANALYSIS OF KNEE JOINT , 2009 .