Displacement vector measurement using instantaneous ultrasound signal phase-multidimensional autocorrelation and Doppler methods

Two new methods of measuring a multidimensional displacement vector using an instantaneous ultrasound signal phase are described, i.e., the multidimensional autocorrelation method (MAM) and multidimensional Doppler method (MDM). A high measurement accuracy is achieved by combining either method with the lateral Gaussian envelope cosine modulation method (LGECMM) or multidirectional synthetic aperture method (MDSAM). Measurement accuracy is evaluated using simulated noisy echo data. Both methods yield accurate measurements comparable to that of our previously developed cross-spectrum phase gradient method (MCSPGM); however, they require less computational time (the order, MDM ≪ MAM ≈ MCSPGM) and would provide realtime measurements. Moreover, comparisons of LGECMM and MDSAM performed by geometrical evaluations clarifies that LGECMM has potentials to yield more accurate measurements with less computational time. Both MAM and MDM can be applied to the measurement of tissue strain, blood flow, sonar data, and other target motions.

[1]  K. W. Cattermole The Fourier Transform and its Applications , 1965 .

[2]  D. Baker Pulsed Ultrasonic Doppler Blood-Flow Sensing , 1970, IEEE Transactions on Sonics and Ultrasonics.

[3]  Bernard D. Steinberg,et al.  Principles of aperture and array system design: Including random and adaptive arrays , 1976 .

[4]  M. Fox Multiple crossed-beam ultrasound Doppler velocimetry , 1978 .

[5]  R. Cabot A note on the application of the Hilbert transform to time delay estimation , 1981 .

[6]  L. Wilson,et al.  Ultrasonic measurement of small displacements and deformations of tissue. , 1982, Ultrasonic imaging.

[7]  C. Kasai,et al.  Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique , 1985, IEEE 1985 Ultrasonics Symposium.

[8]  G. Trahey,et al.  Angle Independent Ultrasonic Detection of Blood Flow , 1987, IEEE Transactions on Biomedical Engineering.

[9]  V. Newhouse,et al.  Ultrasound Doppler Probing of Flows Transverse with Respect to Beam Axis , 1987, IEEE Transactions on Biomedical Engineering.

[10]  S. Yagi Local displacement analysis of inhomogeneous soft tissue by spatial correlation of rf echo signals , 1988 .

[11]  W.D. O'Brien,et al.  Pulsed Doppler accuracy assessment due to frequency-dependent attenuation and Rayleigh scattering error sources , 1990, IEEE Transactions on Biomedical Engineering.

[12]  W. O’Brien,et al.  Flow velocity profile via time-domain correlation: error analysis and computer simulation , 1990, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  J. Ophir,et al.  Elastography: A Quantitative Method for Imaging the Elasticity of Biological Tissues , 1991, Ultrasonic imaging.

[14]  S. Hahn,et al.  Multidimensional complex signals with single-orthant spectra , 1992, Proc. IEEE.

[15]  W.D. O'Brien,et al.  Current time-domain methods for assessing tissue motion by analysis from reflected ultrasound echoes-a review , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  M. O’Donnell,et al.  Internal displacement and strain imaging using ultrasonic speckle tracking , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  Kiyoshi Nakayama,et al.  Phantom Experiment on Estimation of Shear Modulus Distribution in Soft Tissue from Ultrasonic Measurement of Displacement Vector Field , 1995 .

[18]  J.T. Powers,et al.  An axial velocity estimator for ultrasound blood flow imaging, based on a full evaluation of the Doppler equation by means of a two-dimensional autocorrelation approach , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  J. Arendt Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging: Field: A Program for Simulating Ultrasound Systems , 1996 .

[20]  K. Kristoffersen,et al.  An extended autocorrelation method for estimation of blood velocity , 1997, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  M.E. Aderson,et al.  Multi-dimensional velocity estimation with ultrasound using spatial quadrature , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  J. Jensen,et al.  A new method for estimation of velocity vectors , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[23]  C. Sumi,et al.  Fine elasticity imaging utilizing the iterative RF-echo phase matching method , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[24]  H. Ermert,et al.  A time-efficient and accurate strain estimation concept for ultrasonic elastography using iterative phase zero estimation , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  M.A. Lubinski,et al.  Speckle tracking methods for ultrasonic elasticity imaging using short-time correlation , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[26]  Ultrasonic measurement of axial strain when tissue deforms dominantly in lateral direction-method demonstration on agar phantom , 1999, Proceedings of the First Joint BMES/EMBS Conference. 1999 IEEE Engineering in Medicine and Biology 21st Annual Conference and the 1999 Annual Fall Meeting of the Biomedical Engineering Society (Cat. N.

[27]  J A Jensen,et al.  A new estimator for vector velocity estimation. , 2001, IEEE transactions on ultrasonics, ferroelectrics, and frequency control.

[28]  J. Jensen,et al.  A new estimator for vector velocity estimation [medical ultrasonics] , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[29]  Hans Torp,et al.  Ultrasound-based vessel wall tracking: an auto-correlation technique with RF center frequency estimation. , 2002, Ultrasound in medicine & biology.

[30]  J Ophir,et al.  Analysis of an Adaptive Strain Estimation Technique in Elastography , 2002, Ultrasonic imaging.

[31]  J. Jensen,et al.  In-vivo synthetic aperture flow imaging in medical ultrasound , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[32]  Xunchang Chen,et al.  Lateral speckle tracking using synthetic lateral phase , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[33]  C. Sumi,et al.  Usefulness of ultrasonic strain measurement- based shear modulus reconstruction for diagnosis and thermal treatment , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[34]  Didier Vray,et al.  Beamforming Scheme for 2D Displacement Estimation in Ultrasound Imaging , 2005, EURASIP J. Adv. Signal Process..

[35]  ジュ−ホ・イ,et al.  Beamforming apparatus and method in a multiple antenna system , 2005 .

[36]  C. Sumi Our recent strain-measurement-based shear modulus reconstruction , 2005, IEEE Ultrasonics Symposium, 2005..

[37]  M. O’Donnell,et al.  3-D Correlation-Based Speckle Tracking , 2005, Ultrasonic imaging.

[38]  C. Sumi,et al.  Multidimensional Displacement Vector Measurement Methods Utilizing Instantaneous Phase , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[39]  A. Basarab,et al.  P3H-2 Improved Beamforming for Lateral Oscillations in Elastography Using Synthetic Aperture Imaging , 2006, 2006 IEEE Ultrasonics Symposium.

[40]  C. Sumi Reconstructions of shear modulus, poisson's ratio, and density using approximate mean normal stress /spl lambda//spl epsiv//sub /spl alpha//spl alpha// as unknown , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[41]  K. Boone,et al.  Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.

[42]  Chikayoshi Sumi,et al.  Spatially variant regularization for tissue strain measurement and shear modulus reconstruction , 2007, Journal of Medical Ultrasonics.

[43]  C. Sumi Ultrasonic axial strain measurement for lateral tissue deformation. , 2007, Ultrasound in medicine & biology.

[44]  Increasing Accuracy of Tissue Shear Modulus Reconstruction Using Ultrasonic Strain Tensor Measurement , 2008 .