Frequency-compression outcomes in listeners with steeply sloping audiograms

Previous investigation of an experimental, wearable frequency-compression hearing aid revealed improvements in speech perception for a group of listeners with moderately sloping audiograms (Simpson et al, 2005). In the frequency-compression hearing aid, high frequencies (above 1600 Hz) were amplified in addition to being lowered in frequency. Lower frequencies were amplified without frequency shifting. In the present study, an identical frequency-compression scheme was evaluated in a group of seven subjects, all of whom had steeply sloping hearing losses. No significant differences in group mean scores were found between the frequency-compression device and a conventional hearing instrument for understanding speech in quiet. Testing in noise showed improvements for the frequency-compression scheme for only one of the five subjects tested. Subjectively, all but one of the subjects preferred the sound quality of the conventional hearing instruments. In conclusion, the experimental frequency-compression scheme provided only limited benefit to these listeners with steeply sloping hearing losses. Sumario Las investigaciones previas sobre un auxiliar auditivo experimental con compresión de frecuencia revelaron una mejor percepción del lenguaje en un grupo de oyentes con audiogramas de pendiente moderada (Simpson y col., 2005). En el auxiliar auditivo con compresión de frecuencia, las frecuencias agudas (por encima de 1600Hz) se amplificaron además de ser reducidas en frecuencia. Las frecuencias más graves fueron amplificadas sin cambio en la frecuencia. En el presente estudio, un esquema similar de compresión de frecuencia fue evaluado en un grupo de 7 sujetos, todos los cuales tenían hipoacusia con pendientes abruptas. No se encontraron diferencias significativas en los puntajes medios de grupo para entender el lenguaje en silencio entre el dispositivo con compresión de frecuencia y el instrumento convencional. La evaluación en ruido mostró mejoría para el esquema de compresión de la frecuencia en sólo uno de los cinco sujetos evaluados. Subjetivamente, todos menos uno de los sujetos, prefirieron la calidad del sonido de los instrumentos auditivos convencionales. En conclusión, el esquema experimental de compresión de frecuencia aportó sólo un beneficio limitado para los oyentes con hipoacusias de pendiente abrupta.

[1]  C M Reed,et al.  Discrimination and identification of frequency-lowered speech in listeners with high-frequency hearing impairment. , 1985, The Journal of the Acoustical Society of America.

[2]  Bart Nooteboom,et al.  An International Comparison , 2000 .

[3]  Hugh J. McDermott,et al.  Improvements in speech perception with an experimental nonlinear frequency compression hearing device , 2005, International journal of audiology.

[4]  H. Dillon,et al.  An international comparison of long‐term average speech spectra , 1994 .

[5]  G Keidser,et al.  NAL-NL1 procedure for fitting nonlinear hearing aids: characteristics and comparisons with other procedures. , 2001, Journal of the American Academy of Audiology.

[6]  B. Moore,et al.  Effects of low pass filtering on the intelligibility of speech in noise for people with and without dead regions at high frequencies. , 2001, The Journal of the Acoustical Society of America.

[7]  C M Rankovic,et al.  An application of the articulation index to hearing aid fitting. , 1991, Journal of speech and hearing research.

[8]  M Velmans,et al.  The acceptability of spectrum-preserving and spectrum-destroying transposition to severely hearing-impaired listeners. , 1983, British journal of audiology.

[9]  G. E. Peterson,et al.  Revised CNC lists for auditory tests. , 1962, The Journal of speech and hearing disorders.

[10]  R. Daniloff,et al.  Intelligibility of vowels altered in duration and frequency. , 1968, The Journal of the Acoustical Society of America.

[11]  Robyn M. Cox,et al.  The Abbreviated Profile of Hearing Aid Benefit , 1995, Ear and hearing.

[12]  Max Velmans The Design of Speech Recoding Devices for the Deaf: University of Manchester , 1974 .

[13]  B. Moore,et al.  A Test for the Diagnosis of Dead Regions in the Cochlea , 2000, British journal of audiology.

[14]  Hugh J. McDermott,et al.  Preliminary results with the AVR ImpaCt frequency-transposing hearing aid. , 2001, Journal of the American Academy of Audiology.

[15]  J Jerger,et al.  Comparison of performance with frequency transposition hearing aids and conventional hearing aids. , 1997, Journal of the American Academy of Audiology.

[16]  H J McDermott,et al.  Improvements in speech perception with use of the AVR TranSonic frequency-transposing hearing aid. , 1999, Journal of speech, language, and hearing research : JSLHR.

[17]  Thomas Baer,et al.  Effects of lowpass filtering on speech intelligibility for listeners with dead regions at high frequencies. , 2000 .

[18]  R V Shannon,et al.  Effects of amplitude nonlinearity on phoneme recognition by cochlear implant users and normal-hearing listeners. , 1998, The Journal of the Acoustical Society of America.

[19]  H J McDermott,et al.  Speech Perception with Steeply Sloping Hearing Loss: Effects of Frequency Transposition , 2000, British journal of audiology.

[20]  J. Oghalai,et al.  Chapter 37 – Cochlear Hearing Loss , 2005 .

[21]  H. Keselman,et al.  Multiple Comparison Procedures , 2005 .

[22]  B C Moore,et al.  Further evaluation of a model of loudness perception applied to cochlear hearing loss. , 1999, The Journal of the Acoustical Society of America.

[23]  C M Reed,et al.  Discrimination of speech processed by low-pass filtering and pitch-invariant frequency lowering. , 1983, The Journal of the Acoustical Society of America.

[24]  R R Hurtig,et al.  Proportional frequency compression of speech for listeners with sensorineural hearing loss. , 1999, The Journal of the Acoustical Society of America.

[25]  T. M. Nearey Static, dynamic, and relational properties in vowel perception. , 1989, The Journal of the Acoustical Society of America.

[26]  D Ling,et al.  Three experiments on frequency transposition. , 1968, American annals of the deaf.

[27]  C. Turner,et al.  High-frequency audibility: benefits for hearing-impaired listeners. , 1998, The Journal of the Acoustical Society of America.

[28]  A R Thornton,et al.  Low-frequency hearing loss: perception of filtered speech, psychophysical tuning curves, and masking. , 1977, The Journal of the Acoustical Society of America.

[29]  B. Moore Dead Regions in the Cochlea: Diagnosis, Perceptual Consequences, and Implications for the Fitting of Hearing Aids , 2001, Trends in amplification.