Discrepancies between Doppler and catheter gradients in aortic prosthetic valves in vitro. A manifestation of localized gradients and pressure recovery.

To evaluate possible causes of discrepancy between Doppler and catheter gradients across prosthetic valves, five sizes (19-27 mm) of St. Jude and Hancock valves were studied in an aortic pulsatile flow model. Catheter gradients at multiple sites distal to the valve were compared with simultaneously obtained Doppler gradients. In the St. Jude valve, significant differences between Doppler and catheter gradients measured 30 mm downstream from the valve were found: Doppler gradients exceeded peak catheter gradients of 10 mm Hg or more by 81 +/- 35% (15 +/- 3.6 mm Hg), and mean catheter gradients by 71 +/- 11% (10.3 +/- 2.5 mm Hg). When the catheter was pulled back through the tunnel-like central orifice of the valve, high localized gradients at the valve plane and significant early pressure recovery were found. When the catheter was pulled back through the large side orifices, gradients at the same level were only 46 +/- 6% of the central orifice gradients (mean difference, 7.6 +/- 4.5 mm Hg). Doppler peak and mean gradients showed excellent agreement with the highest central orifice catheter gradients (mean difference, 1.0 +/- 3.1 and 0.9 +/- 1.5 mm Hg, respectively). A significantly better agreement between Doppler and catheter gradients at 30 mm was found for the Hancock valve, although Doppler peak and mean gradients were still slightly greater than catheter gradients. Doppler gradients exceeded catheter gradients by 18 +/- 10% (3.4 +/- 1.9 mm Hg) and 13 +/- 11% (2.1 +/- 0.9 mm Hg), respectively. When the catheter was pulled back through the valve, the highest gradients were found approximately 20 mm distal to the valve ring.(ABSTRACT TRUNCATED AT 250 WORDS)

[1]  S. Wann,et al.  Doppler Echocardiographic Evaluation of Hancock and Bjork-Shiley Prosthetic Valves , 2010 .

[2]  J B Seward,et al.  Continuous wave Doppler echocardiographic measurement of prosthetic valve gradients. A simultaneous Doppler-catheter correlative study. , 1989, Circulation.

[3]  Clark Re,et al.  A computerized physiologic pulse duplicator for in-vitro hydrodynamic and ultrasonic studies of prosthetic heart valves. , 1989 .

[4]  A. Weyman,et al.  Pressure recovery distal to a stenosis: potential cause of gradient "overestimation" by Doppler echocardiography. , 1989, Journal of the American College of Cardiology.

[5]  R. E. Clark,et al.  A computerized physiologic pulse duplicator for in-vitro hydrodynamic and ultrasonic studies of prosthetic heart valves. , 1989, Biomedical Instrumentation & Technology.

[6]  S. Evans,et al.  The end of the p value? , 1988, British heart journal.

[7]  R. Rothbart,et al.  Overestimation by Doppler echocardiography of pressure gradients across Starr-Edwards prosthetic valves in the aortic position. , 1988, The American journal of cardiology.

[8]  A. Yoganathan,et al.  Continuous-Wave Doppler Velocities and Gradients Across Fixed Tunnel Obstructions: Studies In Vitro and In Vivo , 1987, Circulation.

[9]  A. J. Ridgway Ultrasound doppler evaluation of mechanical aortic heart valves , 1986 .

[10]  R A Levine,et al.  Validation of continuous-wave Doppler echocardiographic measurements of mitral and tricuspid prosthetic valve gradients: a simultaneous Doppler-catheter study. , 1986, Circulation.

[11]  M Jones,et al.  In vitro hemodynamic characteristics of tissue bioprostheses in the aortic position. , 1986, The Journal of thoracic and cardiovascular surgery.

[12]  J. Fisher,et al.  Comparison of Doppler ultrasound velocity measurements with pressure differences across bioprosthetic valves in a pulsatile flow model. , 1986, Cardiovascular research.

[13]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[14]  A P Yoganathan,et al.  In vitro pulsatile flow velocity and shear stress measurements in the vicinity of mechanical mitral heart valve prostheses. , 1986, Journal of biomechanics.

[15]  A. Tajik,et al.  Validation of instantaneous pressure gradients measured by continuous-wave Doppler in experimentally induced aortic stenosis. , 1985, The American journal of cardiology.

[16]  L. Hatle,et al.  Aortic stenosis in adults. Non-invasive estimation of pressure differences by continuous wave Doppler echocardiography. , 1985, British heart journal.

[17]  P. Teirstein,et al.  The accuracy of Doppler ultrasound measurement of pressure gradients across irregular, dual, and tunnellike obstructions to blood flow. , 1985, Circulation.

[18]  A. Labovitz,et al.  Doppler hemodynamic evaluation of prosthetic (Starr-Edwards and Björk-Shiley) and bioprosthetic (Hancock and Carpentier-Edwards) cardiac valves. , 1985, The American journal of cardiology.

[19]  J. Seward,et al.  Continuous-wave Doppler echocardiographic assessment of severity of calcific aortic stenosis: a simultaneous Doppler-catheter correlative study in 100 adult patients. , 1985, Circulation.

[20]  K B Chandran,et al.  Pulsatile flow past St. Jude Medical bileaflet valve. An in vitro study. , 1985, The Journal of thoracic and cardiovascular surgery.

[21]  S. Goldberg,et al.  In vitro verification of Doppler prediction of transvalve pressure gradient and orifice area in stenosis. , 1984, The American journal of cardiology.

[22]  A P Yoganathan,et al.  Bileaflet, tilting disc and porcine aortic valve substitutes: in vitro hydrodynamic characteristics. , 1984, Journal of the American College of Cardiology.

[23]  David J. Sahn,et al.  DOPPLER ULTRASOUND IN CARDIOLOGY: PHYSICAL PRINCIPLES AND CLINICAL APPLICATIONS , 1983 .

[24]  M. M. Black,et al.  In vitro evaluation of prosthetic heart valves: anomalies and limitations. , 1982, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[25]  H. Meisner,et al.  Flow pattern and velocity field distal to human aortic and artificial heart valves as measured simultaneously by ultramicroscope anemometry in cylindrical glass tubes. , 1980, The Thoracic and cardiovascular surgeon.

[26]  L Hatle,et al.  Non-invasive assessment of aortic stenosis by Doppler ultrasound. , 1980, British heart journal.

[27]  J. Holen,et al.  An Ultrasound Doppler Technique for the Noninvasive Determination of the Pressure Gradient in the Bjork-Shiley Mitral Valve , 1979, Circulation.

[28]  A P Yoganathan,et al.  Pressure drops across prosthetic aortic heart valves under steady and pulsatile flow--in vitro measurements. , 1979, Journal of biomechanics.

[29]  C. Clark,et al.  The fluid mechanics of aortic stenosis--I. Theory and steady flow experiments. , 1976, Journal of biomechanics.

[30]  C Clark,et al.  The fluid mechanics of aortic stenosis - II. Unsteady flow experiments. , 1976, Journal of biomechanics.

[31]  Howard L. Moscovitz,et al.  From cardiac catheterization data to hemodynamic parameters , 1972 .