Enhanced computational prediction of polyethylene wear in hip joints by incorporating cross-shear and contact pressure in additional to load and sliding distance: effect of head diameter.
暂无分享,去创建一个
Zhongmin Jin | John Fisher | Lu Kang | J. Fisher | A. Galvin | Zhongmin Jin | L. Kang | Alison L Galvin
[1] S H Teoh,et al. An elasto-plastic finite element model for polyethylene wear in total hip arthroplasty. , 2002, Journal of biomechanics.
[2] V. Saikko,et al. Effect of contact pressure on wear and friction of ultra-high molecular weight polyethylene in multidirectional sliding , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[3] M H Aliabadi,et al. Total hip arthroplasty wear simulation using the boundary element method. , 2007, Journal of biomechanics.
[4] T D Brown,et al. Finite element analysis of acetabular wear. Validation, and backing and fixation effects. , 1997, Clinical orthopaedics and related research.
[5] J Fisher,et al. Wear and biological activity of highly crosslinked polyethylene in the hip under low serum protein concentrations , 2007, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[6] J. Fisher,et al. Influence of cross shear on the wear of polyethylene: a finite element study , 2005 .
[7] J Fisher,et al. A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates , 1999, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[8] C. Bragdon,et al. The Importance of Multidirectional Motion on the Wear of Polyethylene , 1996, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[9] Zhongmin Jin,et al. Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPE. , 2008, Journal of biomechanics.
[10] B. Morrey,et al. Effect of femoral head size on wear of the polyethylene acetabular component. , 1990, The Journal of bone and joint surgery. American volume.
[11] R Pietrabissa,et al. Wear of polyethylene cups in total hip arthroplasty: a parametric mathematical model. , 1998, Medical engineering & physics.
[12] B. Fregly,et al. Quantifying Multidirectional Sliding Motions in Total Knee Replacements , 2005 .
[13] Paulo R Fernandes,et al. Computational hip joint simulator for wear and heat generation. , 2007, Journal of biomechanics.
[14] Thomas D. Brown,et al. Adaptiive finite element modeling of long‐term polyethylene wear in total hip arthroplasty , 1996 .
[15] J Fisher,et al. Microscopic asperity contact and deformation of ultrahigh molecular weight polyethylene bearing surfaces , 2003, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[16] James Shih-Shyn Wu,et al. The computer simulation of wear behavior appearing in total hip prosthesis , 2003, Comput. Methods Programs Biomed..
[17] A. Wang,et al. Effect of contact stress on friction and wear of ultra-high molecular weight polyethylene in total hip replacement , 2001, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[18] I. Paul,et al. On the origins of high in vivo wear rates in polyethylene components of total joint prostheses. , 1979, Clinical orthopaedics and related research.
[19] T D Brown,et al. The Frank Stinchfield Award. 3-Dimensional sliding/contact computational simulation of total hip wear. , 1996, Clinical orthopaedics and related research.
[20] D L Bartel,et al. The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants. , 1985, Journal of biomechanical engineering.
[21] John Fisher,et al. The influence of contact stress on the wear of UHMWPE for total replacement hip prostheses , 1995 .
[22] J. Fisher,et al. The influence of stress conditions on the wear of UHMWPE for total joint replacements , 1997, Journal of materials science. Materials in medicine.
[23] J Fisher,et al. Wear simulation of ultra-high molecular weight polyethylene hip implants by incorporating the effects of cross-shear and contact pressure , 2008, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[24] J Fisher,et al. A simple fully integrated contact-coupled wear prediction for ultra-high molecular weight polyethylene hip implants , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[25] Zhongmin Jin,et al. PRESIDENTIAL GUEST LECTURE: Tribology of Alternative Bearings , 2006, Clinical orthopaedics and related research.
[26] John J Callaghan,et al. Local head roughening as a factor contributing to variability of total hip wear: a finite element analysis. , 2002, Journal of biomechanical engineering.
[27] R Pietrabissa,et al. Improved mathematical model of the wear of the cup articular surface in hip joint prostheses and comparison with retrieved components , 2001, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[28] John J Callaghan,et al. Kinetically Critical Sites of Femoral Head Roughening for Wear Rate Acceleration in Total Hip Arthroplasty , 2005, Clinical orthopaedics and related research.