Optical noninvasive calculation of hemoglobin components concentrations and fractional oxygen saturation using a ring-scattering pulse oximeter

The deficiencies of the currently used pulse oximeter are discussed in diverse literature. A hazardous pitfalls of this method is that the pulse oximeter will not detect carboxyhemoglobin (COHb) and methemoglobin (metHb) concentrations. This leads to incorrect measurement of oxygen saturation by carbon monoxide poisoning and methemoglobinemia. Also the total hemoglobin concentration will not be considered and can only be measured in-vitro up to now. A second pitfall of the standard pulse oximetry is that it will not be able to show a result by low perfusion of tissues. This case is available inter alia when the patient is under shock or has a low blood pressure. The new non-invasive system we designed measures the actual (fractional) oxygen saturation and hemoglobin concentration. It will enable us also to measure COHb and metHb. The measurement can be applied at better perfused body central parts. Four or more light emitting diodes (LEDs) or laser diodes (LDs) and five photodiodes (PDs) are used. The reflected light signal detected by photodiodes is processed using a modified Lambert-Beer law (I=I0•e-α.d ). According to this law, when a non scattering probe is irradiated with light having the incident intensity I0, the intensity of transmitted light I decays exponentially with the absorption coefficient a of that probe and its thickness d. Modifications of this law have been performed following the theoretical developed models in literature, Monte Carlo simulation and experimental measurement.

[1]  A. Roggan,et al.  Optical Properties of Circulating Human Blood in the Wavelength Range 400-2500 nm. , 1999, Journal of biomedical optics.

[2]  Frans F. Jobsis-vanderVliet DISCOVERY OF THE NEAR-INFRARED WINDOW INTO THE BODY AND THE EARLY DEVELOPMENT OF NEAR-INFRARED SPECTROSCOPY , 1999 .

[3]  Chia-Wei Sun,et al.  Polarized light propagation through scattering media: time-resolved Monte Carlo simulations and experiments. , 2003, Journal of biomedical optics.

[4]  M. H. Koelink,et al.  Laser Doppler velocimetry and Monte Carlo simulations on models for blood perfusion in tissue. , 1995, Applied optics.

[5]  T. L. Rusch,et al.  Signal processing methods for pulse oximetry , 1996, Comput. Biol. Medicine.

[6]  M W Wukitsch,et al.  Pulse oximetry: Historical review and Ohmeda functional analysis , 1987, International journal of clinical monitoring and computing.

[7]  B. Hooper Optical-thermal response of laser-irradiated tissue , 1996 .

[8]  Michaelis Ba,et al.  Pulse oximetry: Analysis of theory, technology, and practice , 2005, Journal of Clinical Monitoring.

[9]  J. Sinex Pulse oximetry: principles and limitations. , 1999, The American journal of emergency medicine.

[10]  J. Severinghaus,et al.  History and recent developments in pulse oximetry. , 1993, Scandinavian journal of clinical and laboratory investigation. Supplementum.

[11]  W. Zijlstra,et al.  Absorption spectra of human fetal and adult oxyhemoglobin, de-oxyhemoglobin, carboxyhemoglobin, and methemoglobin. , 1991, Clinical chemistry.

[12]  J. Salyer,et al.  Neonatal and pediatric pulse oximetry. , 2003, Respiratory care.